VeriSafe Retrofit Enclosure SPECIFICATION SHEET specifications VeriSafe Retrofit Enclosure The VeriSafe Retrofit Enclosure is a small VS-AVT-RBOX: Complete enclosure enclosure with the VeriSafe AVT installed. The to retrofit equipment VeriSafe Retrofit Enclosure allows the VeriSafe with VeriSafe AVT to be added to existing applications where a Absence of Voltage VeriSafe AVT would not physically fit in the Tester. Includes 8 x existing equipment or where adding knockouts for 8 x 4 panel and the indicator module is not permitted. Installation AVT device with is fast and easy as the enclosure is able to be 10ft. sensor leads mounted in several orientations with 4 pre-drilled and 2ft. system conduit knockouts to route the VeriSafe AVT cable. sensor leads. VeriSafe Insulation Piercing Connectors VS-CKP14-6: VeriSafe Insulation Piercing Connection technical information Kit for Tapping 14 to 6 AWG conductors. Dimensions: 8 W x 4 D x 8 H Kit includes 3 connectors for Enclosure Materials: 16 gauge steel installment of 1 AVT. Conduit Ports: (4) 0.875 inch conduit holes for size conduit VS-CKP4-000: VeriSafe Insulation Piercing Connection (3) removable hole plugs for unused conduit holes Kit for Tapping 4 to Operating Temperature: 0C to + 60C (32F to 140F) 3/0 AWG conductors. Kit includes 3 Altitude: Up to 5000 meters (3.1 miles) connectors for installment of 1 AVT. Electrical Systems: For use in 1 and 3-phase AC Systems Voltage Detection Range: Up to 600V AC (50/60Hz), 600V DC Rated tolerance +10% VeriSafe Split Bolt ConnectorsVS- CKSB10-8: VeriSafe Split Bolt Degree of Protection: Type (UL, NEMA, CSA) 12, 4, 13, IP66 Connection Kit for Listings: UL 508A tapping 10 to 8 AWG conductors. For use with VeriSafe Absence of Voltage Tester. key features and benefits VS-CKSB6-2: VeriSafe Split Bolt Compact & Space Saving: Utilize an external enclosure to install the VeriSafe AVT Connection Kit for in existing applications: tapping 6 to 2 AWG conductors. For use where space is limited for the AVT indicator with VeriSafe and/or isolation module Absence of Voltage adding the AVT indicator module to the door Tester. is not possible VS-CKSB1-00: VeriSafe Split Bolt Connection Kit for Fast Installation: Use existing conduit ports and knockouts to eliminate tapping 2 to 2/0 modifications to existing equipment. AWG conductors. For use with VeriSafe Absence Flexible design allows multiple mounting orientations of Voltage Tester. Verisafe AVT is pre-installed. Tester. applications The VeriSafe Retrofit Enclosure is optimized environments. The VeriSafe Retrofit to add the VeriSafe AVT to existing Enclosure has a heavy duty, continuously equipment with minimal modifications. The hinged cover that provides a 180 degree has ingress ratings to support use in harsh opening. www.panduit.comVeriSafe Retrofit Enclosure part information Part Number Description VS-AVT-RBOX Complete enclosure to retrofit equipment with VeriSafe Absence of Voltage Tester. Includes 8 x 8 x 4 panel and AVT device with 10ft. sensor leads and 2ft. system cable. Dimensions in inches millimeters related products Part Number Description VS-CKP14-6 VeriSafe Insulation Piercing Connection Kit for Tapping 14 to 6 AWG conductors. Kit includes connectors to terminate sensor leads for (1) AVT. VS-CKP4-000 VeriSafe Insulation Piercing Connection Kit for Tapping 4 to 3/0 AWG conductors. Kit includes connectors to terminate sensor leads for (1) AVT. VS-CKSB10-8 VeriSafe Split Bolt Connection Kit for tapping 10 to 8 AWG conductors. Kit includes connectors to terminate sensor leads for (1) AVT. VS-CKSB6-2 VeriSafe Split Bolt Connection Kit for tapping 6 to 2 AWG conductors. Kit includes connectors to terminate sensor leads for (1) AVT. VS-CKSB1-00 VeriSafe Split Bolt Connection Kit for tapping 2 to 2/0 AWG conductors. Kit includes connectors to terminate sensor leads for (1) AVT. VeriSafe Insulation Piercing Connectors VeriSafe Split Bolt Connectors DISCLAIMER: The information contained herein is intended as a guide for use by persons having technical skill at their own discretion and risk. Before using, buyer shall determine the suitability of the Panduit product for his intended use and buyer assumes all risk and liability whatsoever in connection therewith. WORLDWIDE SUBSIDIARIES AND SALES OFFICES PANDUIT US/CANADA PANDUIT EUROPE LTD. PANDUIT SINGAPORE PTE. LTD. PANDUIT JAPAN PANDUIT LATIN AMERICA PANDUIT AUSTRALIA PTY. LTD. Phone: 800.777.3300 London, UK Republic of Singapore Tokyo, Japan Guadalajara, Mexico Victoria, Australia cs-emea panduit.com cs-ap panduit.com cs-japan panduit.com cs-la panduit.com cs-aus panduit.com Phone: 44.20.8601.7200 Phone: 65.6305.7575 Phone: 81.3.6863.6000 Phone: 52.33.3777.6000 Phone: 61.3.9794.9020 For a copy of Panduit product warranties, log on to www.panduit.com/warranty For more information 2018 Panduit Corp. Visit us at www.panduit.com ALL RIGHTS RESERVED. Contact Customer Service by email: cs panduit.com SFSP03-SA-ENG or by phone: 800.777.3300 9/2018