Ultrasonic sensor UC2000-30GM-E6R2-V15 Technical data General specifications Sensing range 80 ... 2000 mm Adjustment range 120 ... 2000 mm Dead band 0 ... 80 mm Standard target plate 100 mm x 100 mm Transducer frequency approx. 180 kHz Response delay 65 ms minimum 195 ms factory setting Indicators/operating means LED green solid: Power-on flashing: Standby mode or program function object detected LED yellow 1 solid: switching state switch output 1 flashing: program function LED yellow 2 solid: switching state switch output 2 flashing: program function LED red solid: temperature/program plug not connected flashing: fault or program function object not detected Temperature/TEACH-IN connector Temperature compensation , Switch points programming , output function setting Electrical specifications Operating voltage U 10 ... 30 V DC , ripple 10 % B SS No-load supply current I 50 mA 0 Model Number Interface Interface type RS 232, 9600 Bit/s , no parity, 8 data bits, 1 stop bit UC2000-30GM-E6R2-V15 Input/Output Synchronization bi-directional Single head system 0 level -U ...+1 V B 1 level: +4 V...+U B Features input impedance: > 12 KOhm synchronization pulse: 100 s, synchronization interpulse Parameterization interface for the period: 2 ms application-specific adjustment of Synchronization frequency the sensor setting via the service Common mode operation 30 Hz program ULTRA 3000 Multiplex operation 30 Hz / n , n = number of sensors , n 5 2 programmable switch outputs Output Hysteresis mode selectable Output type 2 switch outputs PNP, NO/NC, programmable Rated operating current I 200 mA , short-circuit/overload protected e Window mode selectable Voltage drop U 2.5 V d Repeat accuracy 0.1 % of full-scale value Synchronization options Switching frequency f 2.5 Hz Adjustable acoustic power and Range hysteresis H 1 % of the adjusted operating range (default settings), programmable sensitivity Temperature influence 2 % from full-scale value (with temperature compensation) Temperature compensation 0.2 %/K (without temperature compensation) Ambient conditions Ambient temperature -25 ... 70 C (-13 ... 158 F) Diagrams Storage temperature -40 ... 85 C (-40 ... 185 F) Mechanical specifications Characteristic response curve Connection type Connector M12 x 1 , 5-pin Degree of protection IP65 Distance Y m Material 0.6 Housing stainless steel (1.4305 / AISI 303) PBT plastic parts 0.4 Transducer epoxy resin/hollow glass sphere mixture polyurethane foam 0.2 Mass 140 g Factory settings 0.0 Output 1 Switching point: 200 mm 2 1 output function: Switch point operation mode -0.2 output behavior: NO contact Output 2 Switching point: 2000 mm -0.4 output function: Switch point operation mode output behavior: NO contact -0.6 Compliance with standards and -0.8 directives 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 Distance X m Standard conformity Y X Standards EN 60947-5-2:2007+A1:2012 IEC 60947-5-2:2007 + A1:2012 Curve 1: flat surface 100 mm x 100 mm Approvals and certificates Curve 2: round bar, 25 mm EAC conformity TR CU 020/2011 UL approval cULus Listed, General Purpose CSA approval cCSAus Listed, General Purpose CCC approval CCC approval / marking not required for products rated 36 V Refer to General Notes Relating to Pepperl+Fuchs Product Information. Pepperl+Fuchs Group USA: +1 330 486 0001 Germany: +49 621 776 4411 Singapore: +65 6779 9091 1 www.pepperl-fuchs.com fa-info us.pepperl-fuchs.com fa-info de.pepperl-fuchs.com fa-info sg.pepperl-fuchs.com Release date: 2016-08-01 13:43 Date of issue: 2016-08-01 102159 eng.xmlUltrasonic sensor UC2000-30GM-E6R2-V15 Additional Information Dimensions Possible operating modes 1. Switch point mode When A1 < A2, both switch outputs are activated as N.O. contacts. M30 x 1.5 Switch point 1 Switch point 2 A 1 (N.O.) Switch output 1 A 2 (N.O.) Switch output 2 When A1 > A2, both switch outputs are activated as N.C. contacts. 36 A 1 (N.C.) Switch output 1 A2 (N.C.) Switch output 2 2. Window mode To exchange the switching distances is of no effect. A 1 (N.O.) Switch output 1 LED A2 (N.C.) Switch output 2 Temperature probe 3. Latching mode To exchange the switching distances is of no effect. Coded plug A 1 (N.O.) Switch output 1 A2 (N.C.) Switch output 2 Electrical Connection Standard symbol/Connection: (version E6, pnp) 1 (BN) + UB 5 (GY) Sync. 2 (WH) Switch output 1 4 (BK) Switch output 2 3 (BU) - UB Core colors in accordance with EN 60947-5-2. Pinout 1 5 2 4 3 Wire colors in accordance with EN 60947-5-2 1 BN (brown) 2 WH (white) 3 BU (blue) 4 BK (black) 5 GY (gray) Refer to General Notes Relating to Pepperl+Fuchs Product Information. Pepperl+Fuchs Group USA: +1 330 486 0001 Germany: +49 621 776 4411 Singapore: +65 6779 9091 2 www.pepperl-fuchs.com fa-info us.pepperl-fuchs.com fa-info de.pepperl-fuchs.com fa-info sg.pepperl-fuchs.com 5 22 27.5 94 Release date: 2016-08-01 13:43 Date of issue: 2016-08-01 102159 eng.xml