WWW.PHIHONG.COM 75W Power over Ethernet Adapter Ultra Power over Ethernet Single Port Injector Shown here in standard on the left and with NIC option on the right Features Fully Compliant Detection, Proprietary Detection, Disconnect and Disconnect and Voltage Control Overload Protection IEEE802.3 PoE standards Full Protection OCP, OVP Diagnostic LEDs Limited Power Source Gigabit Compatible Single Source 4 Pair Power Current Sharing SNMP Management Option 1 Year Warranty Broken Wire Detection Full Power Cisco AP1250 Support 12.5K and 25K Detection Applications Satellite Receiver Security Cameras Wireless Network Access Points Kiosks LCD Displays Computer Workstations Safety Approvals cUL/UL CE Mechanical Characteristics (Standard Model) Length: 166mm (6.53in) Height: 44mm (1.73in) Width: 80mm (3.15in) Weight: 0.5Kg Output Specifications DC Output Load x2 Model Regulation SNMP 1 Voltage* 4-pair powering Line Load Min. Max. POE75U-1UP-R +56V No 54-57V DC under all 0A 0.67A conditions Line Load Min. Max. 2 POE75U-1UP-N-R +56V Yes 54-57V DC under all 0A 0.67A conditions Notes: 1. 4-pair powering for 2 outputs at 56V, 0.67A 2. Consult factory for availability Phihong is not responsible for any error, and reserves the right to make changes without notice. Please visit our website at www.phihong.com for the most up-to-date specifications and contact information. Revision 1/30/2019 POE75U Characteristics WWW.PHIHONG.COM INPUT: EMC AC Input Voltage Range Complies with FCC Class B 90 to 264VAC Complies with EN55032 Class B AC Input Voltage Rating Isolation Test 100 to 240VAC, 47-63Hz Primary to Secondary: 4242VDC for 1 minute 10mA AC Input Current Primary to Field Ground: 2121VDC for 1 2.0A (RMS) max for 90VAC minute 1.2A (RMS) max for 240VAC Output to Field Ground: 2121VDC Leakage Current Immunity 3.5mA max 254VAC 60Hz ESD: EN61000-4-2. Level 3 RS: EN61000-4-3. Level 3 AC Inrush Current EFT: EN61000-4-4. Level 2 30A (RMS) max for 115VAC Surge: EN61000-4-5. Level 3 60A (RMS) max for 230VAC CS: EN61000-4-6. Level 2 Voltage Dips EN61000-4-11 OUTPUT: Harmonic: EN61000-3-2 Class A Total Output Power 75W Insulation Resistance Primary to Secondary: >10M OHM Ripple and Regulation 500VDC 250mV max Primary to Field Ground: >10M OHM 500VDC DC Offset No data degradation with DC imbalance IEEE 802.3af/at Interoperability 18mA per min. If 25kohm or 12.5Kohm is detected the unit operates in 4-pair powering mode delivering Efficiency 75W. 80% (typical) at max load, 120VAC 60Hz FEATURES: Hold-up Time Cisco Legacy detection 10mS min. 120VAC and max load No external parts required for Legacy devices: Transient O/P Voltage Protection VoIP Phones: 7910,7912,7940,7960 60V max Access Points: 350,1100,1200,1250 ENVIRONMENTAL: Over Voltage/Current, Short Circuit Temperature Protection Operation -20 to +40C Outputs equipped with short circuit Non-operation -25 to +65C protection and overload protection as per Humidity 5 to 90% 802.3af specifications except max average current is 1.34A. The output can be shorted permanently without damage. Revision 1/30/2019