UL1061 18 (16/0.254TA) 80 C 300V SP-1061-18AWG REV.0 Product Description z z Rated temperature: 80C z z Rated voltage : 300 volts z z Tinned copper conductor z z PVC Insulation z z Uniform insulation thickness of wire to ensure z easy stripping and cutting z z Pass UL VW-1 flame test & CSA FT1 z z Uniform insulation thickness of wire to ensure easy stripping and cutting z For use in electronic instrumentation Cross Section Cable Construction AWG 18AWG 2 Conductor Nom. cross Section 0.811mm Strand construction 16/0.254TA0.008mm Stranded diameter (Ref.) 1.17mm Material PVC Insulation Average thickness 0.26mm Min. point thickness 0.21mm 1.70 0.03mm Outer diameter Cable Specification Test item Specification Max. Conductor DC resistance 23.3 ohm/km At 20 C Tensile strength Insulation 10.3 (Mpa) Tensile test at room temp. Elongation Insulation 100% Tensile strength Insulation 70% unaged Aging test Elongation Insulation 65% unaged Heat shock test 1211 C 1h No cracks or splits PHILEX HONG KONG CO.,LTD UL1061 18 (16/0.254TA) 80 C 300V SP-1061-18AWG REV.0 Deformation test 250g Max. 50% 121 1 C 1h Cold bend test -10 1 C 4h No cracks or splits Flame test Pass UL VW-1 Spark test kv 3.0+0.3/-0 Test method: UL 1581 Remark Any conductors having diameter of any strand less than the specified minimum value accepted if CMA (circular mils area) or conductor resistance specified is not exceed. PHILEX HONG KONG CO.,LTD