General Emergency Medical Fire & Purpose Lighting Security FEATURES 12V 35.0 AH 20-hr. Absorbent Glass Mat (AGM) technology for PS-12350 12V 33.0 AH 10-hr. superior performance Rechargeable Sealed Lead Acid Battery Valve regulated, maintenance free spill proof construction PS General Purpose Series Power/volume ratio yielding excellent energy density TERMINALS: (mm) Rugged vibration and impact resistant ABS case and cover NB3: Heavy duty terminal posts with T6: Threaded insert with nut and bolt fasteners 6mm stud fastener Gas recombination technology 16mm 5 year design life 16.5mm 6mm M6 6mm APPROVALS Approved for transport by air. D.O.T., I.A.T.A., F.A.A. and C.A.B. certified U.L. recognized ISO9001:2015 Quality management systems Torque: 3.9~5.4 Nxm Torque: 3.9~5.4 Nxm DIMENSIONS: inch (mm) PERFORMANCE SPECIFICATIONS Nominal Voltage 12 volts (6 cells) L: 7.68 (195) W: 5.12 (130) H: 6.46 (164) Nominal Capacity HT: 7.01 (178) 20-hr. (1.65A to 10.80 volts) 35.0 AH Tolerances are +/- 0.04 in. W 10-hr. (3.07A to 10.80 volts) 33.0 AH (+/- 1mm) and +/- 0.08 in. 5-hr. (5.61A to 10.50 volts) 28.1 AH (+/- 2mm) for height 1-hr. (20.7A to 9.60 volts) 20.7 AH dimensions. All data subject to change without notice. Approximate Weight 23.15 lbs. (10.5 kg) Internal Resistance (approx.) 12.0 milliohms Sealed Rechargeable Max Short-Duration Discharge Current (5 Sec.) 495.0 amperes Battery HT Shelf Life (% of nominal capacity at 68F (20C) MODEL PS-12350 NB H 12 Volt 35.0 Amp. Hr. 1 Month 97% Rechargeable Sealed Lead-Acid Battery 3 Month 91% DC power, constant voltage charge Cycle use: 14.4 - 15.0V(20 C) Standby use: 13.5 - 13.8V(20 C) Initial current: 10.5A MAX 6 Month 83% Warning: Risk of fire, explosion, or burns. 120350400211 Do not disassemble, heat above 60 C, or incinerate. Operating Temperature Range L Charge 32F (0C) to 104F (40C) Discharge 5F (-15C) to 122F (50C) Case ABS Plastic L: 7.72 (196) W: 5.14 (131) H: 6.22 (158) HT: 7.00 (176) GLOBAL HEADQUARTERS POWER-SONIC EMEA (USA AND INTERNATIONAL EXCLUDING EMEA) (EMEA EUROPE, MIDDLE EAST AND AFRICA) PSC-124000-PC Tolerances are +/- 0.04 in. (+/- 1mm) and +/- 0.08 in. (+/- 2mm) for Power-Sonic Corporation Smitspol 4, 3861 RS Nijkerk, Power Sonic Chargers PSC-124000A-C 365 Cabela Dr Suite 300, The Netherlands height dimensions. All data subject to change without notice. Reno, Nevada 89523 T NL: + 31 33 7410 700 USA T UK: + 44 1268 560 686 T: +1 619 661 2020 T FR: + 33 344 32 18 17 E: customer-service power-sonic.com E: salesEMEA power-sonic.com To ensure safe and efficient operation always refer to the latest edition of our Technical Manual, as published on our website. 2018. Power-Sonic Corporation. All rights reserved. All trademarks are the property of their respective owners. All data subject to change without notice. E&O.E www.power-sonic.com 8 13340 01059 8 7mm 6mm 16mm PS SERIES Rev2: 08/2012V 33.0 AH 20-hr. PS-12350 12V 30.7 AH 10-hr. Rechargeable Sealed Lead Acid Battery PS General Purpose Series SHELF LIFE & STORAGE SHELF LIFE & STORAGE LIFE CHARACTERISTICS IN STAND-BY USE LIFE CHARACTERISTICS IN STAND-BY USE 100 SHELF LIFE & STORAGE Charging is not necessary unless 100% of capacity 100 LIFE CHARACTERISTICS IN STAND-BY USE is required. Charging is not Ambient Temperature 20C (68F) necessary unless 100 80 o 100% of capacity Charging before 5 C is required. Ambient Temperature 20C (68F) use is necessary o 80 (41 F) to help recover 100 80 o full capacity. Charging before 5 C use is necessary 60 o 60 80 (41 F) to help recover full capacity. Float Charging Voltage 60 o o 40 o 60 30 C 40 C 20 C 2.25 - 2.30 V/Cell o o o (86 F) Float Charging Voltage 40 (104 F) (68 F) o 20 o o 40 40 C 30 C 20 C 2.25 - 2.30 V/Cell o o o (86 F) (104 F) 0 40 (68 F) 0 20 0 2 4 6 8 10 12 14 16 18 20 0 1 23 4 5 0 0 Years Standing Period (Months) 0 2 4 6 8 10 12 14 16 18 20 0 1 23 4 5 Years Standing Period (Months) CHARGING CHARGERS Cycle Applications: Apply constant voltage charge at Power Sonic offers a wide range of chargers suitable 2.35v/c 2.45v/c (14.1 14.7v for 12v Monobloc) at 20C. for batteries with a variety of capacities. Initial charging current should be set at less than 0.25C Please refer to our website for more information on Amps. Switch to float charge to avoid overcharging. our switch mode and transformer type chargers. Float or Stand-By Service: Apply constant voltage Please contact our technical department for advice if charge of 2.25v/c 2.30v/c (13.5 to 13.8 volts for 12v you have difficulty in locating a suitable charger. Monobloc at 20C. When held at this voltage, the battery will seek its own current level and maintain itself in a fully FURTHER INFORMATION charged condition. Please refer to our website www.power-sonic.com Temperature Compensation: Charging Voltage for both for a complete range of useful downloads, such as Cyclic and Standby applications should be regulated in product catalogs, material safety data sheets (MSDS), relation to ambient temperature. As temperature rises ISO certification, etc. charging voltage should be reduced to prevent overcharge and increased as temperature falls to avoid undercharge. For further charging information including temperature compensation factors, see Power Sonic Technical Manual/ Power Sonic Charger specifications. APPLICATIONS General purpose Medical Emergency lighting Fire and security GLOBAL HEADQUARTERS POWER-SONIC EMEA (USA AND INTERNATIONAL EXCLUDING EMEA) (EMEA EUROPE, MIDDLE EAST AND AFRICA) Power-Sonic Corporation Smitspol 4, 3861 RS Nijkerk, 365 Cabela Dr Suite 300, The Netherlands Reno, Nevada 89523 T NL: + 31 33 7410 700 USA T UK: + 44 1268 560 686 T: +1 619 661 2020 T FR: + 33 344 32 18 17 E: customer-service power-sonic.com E: salesEMEA power-sonic.com To ensure safe and efficient operation always refer to the latest edition of our Technical Manual, as published on our website. 2018. Power-Sonic Corporation. All rights reserved. All trademarks are the property of their respective owners. All data subject to change without notice. E&O.E www.power-sonic.com Capacity Retention Ratio (%) Capacity Retention Ratio (%) Percentage of capacity available (Ah%) Percentage of capacity available (Ah%) PS SERIES Rev2: 08/20