A&F Series Transformer Type Battery Chargers FOR SLA BATTERIES Features Operating Characteristics Electronically regulated - current limited chargers for A Series: Automatic dual rate chargers sense battery sealed lead-acid type batteries. requirements and automatically switch from the fast charge to float mode, or vice versa. LEDs provide visual indication Wall mount plug-in design for 250, 300, 500, 800 series of the charging mode. Automatic chargers combine the and 61000A counter top design for 241000A, 2000, 4000 and 10A series. advantages of float and cycle chargers recharge time is short yet batteries are safe from being overcharged. This Operating temperature range: 32F - 104F (0C - 40C). charger is ideal for cyclic applications where recharge time Input voltage: 110/120 VAC, 60Hz. 122000A and 241000A is critical and the battery may be left on charge indefinitely. can be switched to accept 220/230 VAC, 50Hz. As a result charging is fool-proof. LEDs: For 250A & 500A series: POWER ON and CHARGING MODE (ON=high-rate charging, OFF=float F Series: Float chargers are designed to provide optimum charging). For 300, 800, 1000, & 10A series: FLOAT and life for batteries used in standby applications where FAST CHARGE indicators. For 2000A, 241000A and 4000 charging is continuous. The chargers deliver a constant series: single tri-color indicator. voltage of 2.25 to 2.30 volts per cell which allow the battery Hi-impact resistant thermo-plastic housing for 250, to seek its own current level and maintain itself in a fully 300, 500, and 800 series metal housing for 1000, 2000, charged condition. This series is best suited for burglar 4000, and 10A series. and fire alarm equipment, emergency lighting, memory Screw-type terminals for 250 & 500 series, I/O cord with protection, or UPS systems where the battery serves as battery connectors for 300, 800, 1000, 2000, 4000 and back-up power to the AC source. 10A series chargers. Specifications Dimensions: in. (mm) Nominal Output Voltage Output Weight Model Type Voltage Float/Fast Current (mA) lbs. (kg) Length Width Height PSC-6250F 6 6.83 / NA 400 Fixed volt float 2.20 (56) 1.96 (50) 1.88 (48) 0.50 (0.23) PSC-6250A 6 6.75 / 7.35 400 Dual Rate 2.20 (56) 1.96 (50) 1.88 (48) 0.50 (0.23) PSC-6300A 6 6.84 / 7.35 300 Dual Rate 2.75 (69) 2.75 (70) 3.75 (95) 1.36 (0.62) PSC-61000A 6 6.84 / 7.35 1000 Dual Rate 2.75 (70) 2.75 (70) 3.75 (95) 1.36 (0.62) PSC-12800A 12 13.68 / 14.70 800 Dual Rate 2.75 (69) 2.75 (70) 3.75 (95) 1.36 (0.62) PSC-122000A 12 13.50 / 14.70 2000 Dual Rate 5.55 (141) 3.60 (91) 2.89 (73) 3.80 (1.73) PSC-124000A 12 13.50 / 14.70 4000 Dual Rate 6.65 (169) 5.30 (135) 3.40 (86) 7.40 (3.36) PSC-124000AP 12 13.50 / 14.70 2,500/2,200 Charger/Pwr. Supply 6.65 (169) 5.30 (135) 3.40 (86) 7.40 (3.36) Weve Got The Power.SLA Charger Selection Guide Use with Battery U.L./CSA Charger Model Max Output (mA) Listing Voltage Capacity PSC-6250F 400 6 0.5 - 2 AH U.L. PSC-6250A 400 6 1 - 3 AH U.L. PSC-6300A 300 6 1 - 3 AH CSA/NRTL* PSC-61000A 1000 6 5 - 10 AH CSA/NRTL* PSC-12800A 800 12 4 - 8 AH CSA/NRTL* PSC-122000A** 2000 12 8 - 20 AH CSA PSC-124000A** 4000 12 20 - 40 AH CSA PSC-124000AP*** 3500 12 12- 40 AH CSA * The NRTL/C mark appearing next to the CSA stamp indicates that the charger was also tested to meet U.L. requirements (UL 1310). Under the provisions of this agreement, CSA and U.L. can now test to each others specifications and thus obtain approval for both organizations. ** PSC-122000A and PSC-124000A can be switched to accept 115 VAC or 230 VAC input (47-63 Hz) allowing usage both here and abroad. *** PSC-124000AP should be used when the automatic dual rate charger is used like a power supply. As such it can supply a continuous load current of up to 2.5A, yet still switch into float mode (13.8V) when the battery is fully charged. Notes Recharge time depends on the depth of the preceding When charging batteries in series (positive terminal discharge and the output current of the charger. To of one battery is connected to negative of the other) all determine the approximate recharge time of a fully batteries in the string will receive the same amount of discharged battery, divide the batterys amp. hrs. by charge current, individual battery voltages may vary. the rated output current of the charger and multiply the resulting number of hours by a factor of 1.75 to When charging batteries in parallel (positive terminals compensate for the declining output current during the are connected with positive terminals, negative terminals charge cycle. If the amount of amp. hrs. discharged with negative), all batteries in the string are subject to the from the battery is known, use it instead of the batterys same charge voltage, but the charge current each battery capacity to make the calculation. receives can and will vary until equalization is reached. Power-Sonic does not offer chargers for batteries with capacities higher than 100 AH. If you have any queries or difficulties in locating a suitable charger for batteries above 100AH, our T echnical department will be happy to help. www.power-sonic.com Contact Information INTERNATIONAL SALES DOMESTIC SALES CUSTOMER SERVICE TECHNICAL SUPPORT Tel: +1-650-364-5001 Tel: +1-619-661-2020 Tel: +1-619-661-2030 Tel: +1-619-661-2020 Fax: +1-650-366-3662 Fax: +1-619-661-3650 Fax: +1-619-661-3648 Fax: +1-619-661-3648 international-sales power-sonic.com national-sales power-sonic.com customer-service power-sonic.com support power-sonic.com CORPORATE OFFICE 7550 Panasonic Way San Diego, CA 92154 USA Tel: +1-619-661-2020 Fax: +1-619-661-3650 0810 1M 2010. Power-Sonic Corporation. All rights reserved. All trademarks are the property of their respective owners.