Ericsson Internal E PRODUCT SPECIFICATION 1 (4) Prepared (also subject responsible if other) No. MICJOHH 1/1301-BMR 455 40 Uen Technical Specication Approved Checked Date Rev Reference 28701-BMR 455 40 Rev.B December 2016 PIM 4710 series Power Interface Modules 2016-10-05 A Ericsson AB Input 36-75V, Output up to 20A / 780-1080 W Key Features Industry standard Quarter-brick 57.9 x 36.8 x 20.3 mm (2.28 x 1.45 x 0.80 in) 780 W at 39 Vin, 960 W at 48 Vin, 1080 W at 54 Vin High efficiency, typ. 98.8% at 780 W 15 A output current at 86C, 2 m/s (300 LFM) airflow Low EMI design for CISPR Class B 2 Monitoring via I C 2000 Vdc input to management power output isolation Optimized for ATCA applications and PICMG 3.7 (up to 800 W input power) Basic insulation according to IEC 62368-1 MTBF 2.66 Mh General Characteristics Dual input power feeds and enable Input transient suppression (IEC & ANSI standards) Safety Approvals Design for Environment Reverse polarity protection Input under voltage shutdown Over temperature protection Output current protection Meets requirements in high- A/B Feed loss alarm temperature lead-free soldering processes. Inrush protection and hot swap functionality Hold-up charge and management 3.3 V / up to 7 A management power output Highly automated manufacturing ensures quality ISO 9001/14001 certified supplier Contents Ordering Information .............................................................2 General Information .............................................................2 Safety Specification .............................................................3 Absolute Maximum Ratings ............................................................. 4 Electrical Specification 16A/ 3.3V, 3.6A - 7.0A PIM 4610.............................................. 5 PIM 4710.............................................. 5 20A/ 3.3V, 3.6A - 7.0A EMC Specification ........................................................... 14 Operating Information ........................................................... 18 Thermal Consideration ........................................................... 21 Connections ........................................................... 22 Mechanical Information ........................................................... 23 Soldering Information ........................................................... 24 Delivery Package Information ........................................................... 24 Product Qualification Specification ........................................................... 25 Appendix - PMBus Commands ........................................................... 26 E Technical Specication 28701-BMR 455 40 Rev.B December 2016 PIM 4710 series Power Interface Modules Ericsson AB Input 36-75V, Output up to 20A / 780-1080 W Compatibility with RoHS requirements Ordering Information The products are compatible with the relevant clauses and Product program Output requirements of the RoHS directive 2011/65/EU and have a PIM 4610 16 A & 3.3V, 3.6 A (7 A) maximum concentration value of 0.1% by weight in PIM 4710 20 A & 3.3V, 3.6 A (7 A) homogeneous materials for lead, mercury, hexavalent chromium, PBB and PBDE and of 0.01% by weight in homogeneous materials for cadmium. Exemptions in the RoHS directive utilized in Ericsson Power Modules products are found in the Statement of Compliance document. Product number and Packaging Ericsson Power Modules fulfills and will continuously fulfill all its obligations under regulation (EC) No 1907/2006 PIM 4X10 n1n2n3n4 concerning the registration, evaluation, authorization and Options n n n n 1 2 3 4 restriction of chemicals (REACH) as they enter into force and Mounting is through product materials declarations preparing for the Function obligations to communicate information on substances in the products. Lead length Delivery package Quality Statement The products are designed and manufactured in an industrial Options Description environment where quality systems and methods like ISO n P Through hole 1 9000, Six Sigma, and SPC are intensively in use to boost the continuous improvements strategy. Infant mortality or early n D Standard config. PMBus 2 failures in the products are screened out and they are 2 DA Limited I C (Industry standard) subjected to an ATE-based final test. Conservative design DG PMBus and Power good pin rules, design reviews and product qualifications, plus the 2 DAG Limited I C and Power good pin high competence of an engaged work force, contribute to the high quality of the products. n LA 3.69 mm 3 LB 4.57 mm Warranty n /B Soft tray* 4 Warranty period and conditions are defined in Ericsson Power Modules General Terms and Conditions of Sale. Example: A through-hole mounted, PMBus logic, 3.69 mm pin length product with tray packaging would be PIM 4710 PDLA. Limitation of Liability Ericsson Power Modules does not make any other * Standard variant (i.e. no option selected). warranties, expressed or implied including any warranty of merchantability or fitness for a particular purpose (including, General Information but not limited to, use in life support applications, where Reliability malfunctions of product can cause injury to a persons health or life). The failure rate ( ) and mean time between failures (MTBF= 1/ ) is calculated at max output power and an operating Ericsson AB 2016 ambient temperature (T ) of +40C. Ericsson Power Modules A uses Telcordia SR-332 Issue 2 Method 1 to calculate the The information and specifications in this technical specification is believed to be correct at the time of mean steady-state failure rate and standard deviation ( ). publication. However, no liability is accepted for inaccuracies, printing errors or for any consequences Telcordia SR-332 Issue 2 also provides techniques to thereof. Ericsson AB reserves the right to change the estimate the upper confidence levels of failure rates based on contents of this technical specification at any time without the mean and standard deviation. prior notice. Mean steady-state failure rate, Std. deviation, 377 nFailures/h 15.6 nFailures/h MTBF (mean value) for the PIM 4x10 series = 2.66 Mh. MTBF at 90% confidence level = 2.53 Mh