G01 OEM Module Mechanical With WiFi, BLE and cellular LTE-CAT M1/NB1, the G01 OEM Size: 40mm x 16mm x 2.7mm Module is the latest Pycom triple-bearer MicroPython enabled micro controller on the market today the perfect enterprise 8MB flash memory ESP32 Dual Core grade IoT plaorm ftf or your connected things. Create and Microcontroller and connect your things everywhere, fast. WiFi/Bluetooth 4.2 radio G01 Features - Powerful CPU - 1KM Wifi Range - MicroPython enabled - Fits in a standard breadboard (with headers) LTE CAT M1 / NB1 - Ultra-low power usage: a fraction compared to other connected transceiver micro controllers Processing LTE-M Operating Frequencies - 34 bands supported from 699Mhz to 2690Mhz (Total world- - Espressif ESP32 SoC wide support) - Dual processor + WiFi radio System on Chip. - Network processor handles the WiFi connectivity and the IPv6 stack LTE-M Specification - Main processor is entirely free to run the user application - An extra ULP-coprocessor that can monitor GPIOs, the ADC - One single chip for both CAT M1 and NB1 (yes, only one chip) channels and control most of the internal peripherals during - 3GPP release 13 LTE Advanced Pro deep-sleep mode while only consuming 25uA - Supports narrowband LTE UE categories M1/NB1 - Integrated baseband, RF, RAM memory and power management Security & Certifications Hash / encryption - Reduced Tx power class option - SSL/TLS support up to 1.2 SHA, MD5, DES, AES - Peak power estimations: TX current = 420mA peak 1.5Watt - WPA Enterprise security WiFi Networking RX current = 330mA peak 1.2Watt - AES encryption engine 802.11b/g/n 16mbps - Data rates: Memory - 300 kbps DL Bluetooth - RAM: 4MB - 375 kbps UL (LTE Cat M1 in 1.4 Mhz, HD-FDD) Low energy and classic - Flash Memory: 8MB - 40 kbps DL RTC - GPIO: Up to 22 - 55 kbps UL (LTE Cat M2 in 200 kHz, HD-FDD) Running at 32KHz - Hardware floating point acceleration Interfaces - Python multi-threading - 2 x UART, 2 x SPI, I2C, I2S, micro SD card - Analog channels: 8x12 bit ADCs, 2x8 bit DAC Use the Pymakr IDE - Timers: 2x64 bit with PWM with up to 16 channels Super easy code editor to write your Python scripts - DMA on all peripherals Easy Upload Upload your scripts, and any other files you want to the G01 via the FTP server Power - Voltage Input: 3.3V regulated Locally or remotely Reset the G01 (you can do it locally, or remotely via Telnet) Distributed and manufactured by Pycom Ltd. mechanical methods, without the prior written permission of Pycom Ltd, Registered office: except in the case of brief quotations embodied in critical reviews and High Point, 9 Sydenham Road, Guildford, Surrey GU1 3RX, UK certain other noncommercial uses permitted by copyright law. Copyright 2017 by Pycom Ltd. All rights reserved. No part of this document may be reproduced, distributed, or transmitted in any form or To order contact sales pycom.io by any means, including photocopying, recording, or other electronic or module(s) installed and fully operational. For example, if a host was EU Regulatory Conformance previously authorized as an unintentional radiator under the Declaration of Conformity procedure without a transmitter certified Hereby, Pycom Ltd declares that this device is in compliance module and a module is added, the host manufacturer is responsible with the essential requirements and other relevant provisions of for ensuring that the aerft the module is installed and operational Directive 1999/5/EC the host continues to be compliant with the Part 15B unintentional radiator requirements. Federal Communication Commission Interference Statement The module is limited to OEM installation ONLY. The module is limited to installation in mobile or fixed application. This device complies with Part 15 of the FCC Rules. Operation is We hereby acknowledge our responsibility to provide guidance to subject to the following two conditions: the host manufacturer in the event that they require assistance for ensuring compliance with the Part 15 Subpart B requirements. (1) This device may not cause harmful interference. (2) This device must accept any interference received, including IMPORTANT NOTE: In the event that these conditions cannot interference that may cause undesired operation. be met (for example certain laptop configurations or co-location with another transmitter), then the FCC authorization is no CAUTION: Changes or modifications not expressly approved by the longer considered valid and the FCC ID cannot be used on the party responsible for compliance could void the user s authority to final product. In these circumstances, the OEM integrator will operate the equipment. be responsible for reevaluating the end product(including the transmitter) and obtaining a separate FCC authorization. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of End Product Labeling the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This transmitter module is authorized only for use in device where This equipment generates uses and can radiate radio frequency the antenna may be installed such that 20 cm may be maintained energy and, if not installed and used in accordance with between the antenna and users. The final end product must be the instructions, may cause harmful interference to radio labeled in a visible area with the following: Contains FCC ID: communications.However, there is no guarantee that interference 2AJMTG01XXX. The grantee s FCC ID can be used only when all will not occur in a particular installation. If this equipment does FCC compliance requirements are met. cause harmful interference to radio or television reception, which can be determined by turning the equipment o and on, the userff is The following FCC part 15.19 statement has to also be available on encouraged to try to correct the interference by one or more of the the label: following measures: - Reorient or relocate the receiving antenna. This device complies with Part 15 of FCC rules. Operation is subject - Increase the separation between the equipment and receiver. to the following two conditions: - Connect the equipment into an outlet on a circuit different from (1) this device may not cause harmful interference and that to which the receiver is connected. (2) this device must accept any interference received, including - Consult the dealer or an experienced radio/TV technician for help. interference that may cause undesired operation. RF Warning Statement Manual Information to the End User To comply with FCC RF exposure compliance requirements, the The OEM integrator has to be aware not to provide information to antennas used for this transmitter must be installed to provide a the end user regarding how to install or remove this RF module in separation distance of at least 20 cm from all persons and must not the users manual of the end product which integrates this module. be co-located or operating in conjunction with any other antenna or transmitter. In the user manual of the end product, the end user has to be informed that the equipment complies with FCC radio-frequency This device is intended only for OEM integrators exposure guidelines set forth for an uncontrolled environment. under the following conditions: The end user has to also be informed that any changes or 1) The antenna must be installed such that 20 cm is maintained modifications not expressly approved by the manufacturer could void between the antenna and users, and the user s authority to operate this equipment. 2) The transmitter module may not be co-located with any other transmitter or antenna. The end user manual shall include all required regulatory information/warning as show in this manual. As long as two conditions above are met, further transmitter test will not be required. However, the OEM integrator is still The maximum operating ambient temperature of the equipment responsible for testing their end-product for any additional declared by the manufacturer is compliance requirements required with this module installed. To -20~+85C ensure compliance with all non-transmitter functions the host manufacturer is responsible for ensuring compliance with the Receiver category 3