D a L w p O a p R H r l A i r E 2x3 optional 2x4, low profile design Features 60W power from -40C up to +55C ambient Operating temperature up to +85C with derating AC/DC Converter 4 kVAC/1min reinforced isolation Regulated 2MOPP medical certified, B and BF compliant 4000m/5000m (medical/ITE) operating altitude Converter RACM60-K/OF Class B EMC filter built-in Description 60 Watt 3 The multi-purpose, industrial + household + medical grade AC/DC converter series RACM60-K/OF delivers 60 Watts of output power from -40C to +55C with natural air convection only, and up to Open Frame +85C with derating or forced cooling. With a clear focus on extended thermal performance for sys- tems where space is limited, these 2 x 3 compact modules are designed to gain highest overall 2x3 & 2x4 efficiency levels over the full output load range from universal AC inputs. The RACM60-K/OF has ANSI/AAMI/IEC 60601-1 medical safety and EN 60601-1-2 medical EMC certifications and offers 4kVAC/1 min isolation, 2MOPP and designed to meet B and BF requirements. It is additionally certified Single Output to IEC/EN62368-1(CB Report) and IEC61558-1/-2-16 for industrial applications and IEC/EN60335-1 for household appliances. The robust built-in Class B EMC filter has sufficient margin to allow both In- stallation Class II or Class I PELV with grounded output. A range of mechanical fixing options makes the RACM60 suitable for many different mounting conditions: the standard chassis mount part mates with Molex connectors and the /PCB option permits direct installation in printed circuit boards. Additionally, a 2 x 4 footprint for backwards-compatibility with legacy designs is available on request. Selection Guide Part Input Voltage Output Output Output Efficiency (1) Number Range Voltage Current Power typ. VAC VDC mA W % (2, 3) RACM60-05SK/OF 80-264 5 8000 40 89 (2, 3) RACM60-12SK/OF 80-264 12 5000 60 90 (2, 3) RACM60-15SK/OF 80-264 15 4000 60 90 (2, 3) RACM60-24SK/OF 80-264 24 2500 60 90 (2, 3) RACM60-36SK/OF 80-264 36 1667 60 90 (2, 3) RACM60-48SK/OF 80-264 48 1250 60 90 Notes: Note1: Efficiency is tested at nominal input and full load at +25C ambient Model Numbering RACM60- SK /OF/ - (3) nom. Output Power Packaging options (2) Output Voltage Connection options E314885 (2) Single Case style CERTIFIED EN-60335-1 Notes: Note2: /OF = standard 2x3 open frame version with standard header connectors 2MOPP /OF/PCB-T= 2x3 open frame with PCB mounting pins in single tray packaging (05, 12, 24Vout versions available) 250VAC /OF/2x4 = 2x4 open frame version with standard header connectors (12 and 24Vout versions available) For other case/connection/footprint options, please contact RECOM technical support IEC/EN62368-1 (pending) Note3: without suffix, standard single pack (1pcs/cardboard box) ANSI/AAMI ES60601-1 Ed. 3.1 certified add suffix -CTN for project packaging (4 layers of tray within a carton, for /OF only + MOQ= 1152pcs) CSA/CAN-C22.2 No. 60601-1:14 certified for detail information, refer to PACKAGING INFORMATION IEC/EN60335-1 (pending) IEC/EN61558-1 (pending) IEC/EN61558-2-16 (pending) Ordering Examples: EN60601-1-2 compliant RACM60-05SK/OF 5Vout 2 x 3 open frame standard header connector 1pcs/cardboard box RACM60-24SK/OF/PCB-T 24Vout 2 x 3 open frame PCB mounting pins 12pcs/tray packaging EN55032 compliant RACM60-12SK/OF/2x4 12Vout 2 x 4 open frame standard header connector 1pcs/cardboard box EN55035 compliant RACM60-12SK/OF-CTN 12Vout 2 x 4 open frame standard header connector 48pcs/carton (MOQ= 1152pcs) CB Report (pending) www.recom-power.com REV.: 1/2020 PA-1 a E a S n Y n U c t O e y H sRACM60-K/OF AC/DC Converter Series Specifications (measured Ta= 25C, nom. Vin, full load and after warm-up unless otherwise stated) BASIC CHARACTERISTICS Parameter Condition Min. Typ. Max. Internal Input Filter Pi Type Nom. Input Voltage 100VAC 240VAC 80VAC 264VAC (3,4) Input Voltage Range 120VDC 370VDC 115VAC 1400mA Input Current 230VAC 600mA 115VAC 30A Inrush Current cold start 230VAC 60A ErP Standby Mode Conformity 0.5W 0.3W 115/230VAC Input Power: (Output Load Capability) 1.0W 0.7W No load Power Consumption 230VAC 100mW Input Frequency Range AC Input 47Hz 63Hz Minimum Load 0% 115VAC 0.6 Power Factor 230VAC 0.5 Start-up Time 150ms Rise Time 100ms 115VAC 12ms Hold-up Time 230VAC 50ms Internal Operating Frequency 100% load at nominal Vin 100kHz 5Vout 200mVp-p (5) Output Ripple and Noise 20MHz BW others 1% of Vout Notes: Note3: The products were submitted for safety files at AC-Input operation (90-264VAC) Note4: Output power derating for Line-input of less than 90VAC (derate linearly from 100% at 90VAC to 80% at 80VAC) Note5: Measurements are made with a 0.1F MLCC & 10F E-cap in parallel across output. (low ESR) Efficiency vs. Load RACM60-05SK/OF others 100 100 90 90 80 80 70 70 60 60 50 50 40 40 30 30 115VAC 115VAC 20 20 230VAC 230VAC 10 10 0 0 0 10 20 30 40 50 60 70 80 90 100 0 10 20 30 40 50 60 70 80 90 100 Output Load % Output Load % www.recom-power.com REV.: 1/2020 PA-2 Efficiency % Efficiency %