C C S S O O R R w E E M M T T P P R R a L L R I I E E A A r V V N N A N N T T r Triac dimmable with leading or trailing edge dimmers Features Class II with SELV output (no earth required) AC/DC Converter TRIAC Dimmable Extra-large screw terminals and integrated cable clamps for easy installation LED Power factor corrected >0.95 Dimming range 1..100% Driver RACT18 Compatible with a wide range of dimmers Description 18 Watt The RACT18-xxx series are low cost, triac-dimmable, constant current 18W LED drivers available with 3 either 350mA, 500mA, 700mA, 1.05A or 1.4A full-range outputs. The drivers are Class II (double TRIAC insulated) meaning no earth connection is required. The phase angle dimming works with leading or trailing edge dimmers. The RACT18 is suitable for indoor locations up to 50C ambient temperature and Dimmable is certified for building into furniture for applications such as dimmable shelf lighting, cove lighting or accent lighting. It is CE (LVD + EMC + RoHS) + EAC marked and has the international IEC61347-1 CB Single Output report certification. Selection Guide Part Input Output Output Efficiency Output Number Voltage Range Voltage Range Current min. rated load Power VAC VDC mA % W RACT18-350 198-264 26-52 350 85 18 RACT18-500 198-264 18-36 500 84 18 RACT18-700 198-264 13-26 700 85 18 22++ RoHSRoHS REACHREACH compliantcompliant compliantcompliant 10 from 1010 from 10 RACT18-1050 198-264 9-18 1050 82 18 RACT18-1400 198-264 6.5-13 1400 82 18 All LED Drivers may not be used without a load. They must be switched on the primary side only. M M Noncompliance may damage the LED or reduce its lifetime. Model Numbering RACT18- IEC/EN61347 certified IEC/EN61347-2-13 certified Output Power Output Current EN61547 certified EN62493 certifed EN55015 compliant CB report Specifications (measured Ta= 25C, 240VAC, rated load unless otherwise specified) BASIC CHARACTERISTICS Parameter Condition Min. Typ. Max. Input Voltage Range 198VAC 230VAC 264VAC RACT18-350,1050,1400 110mA Input Current RACT18-500,700 120mA Inrush Current full load 5A No Load Power Consumption 1W Input Frequency Range 50Hz 60Hz Power Factor full load 0.95 THD full load 20% Start-up Time 500ms continued on next page www.recom-power.com REV.: 4/2020 L-1 O O P P E a C C R R O O Y M M n D D O O U U t C C C C E E y T T R R S SRACT18 AC/DC Converter Series Specifications (measured ta= 25C, 240VAC, rated load unless otherwise specified) Parameter Condition Min. Typ. Max. RACT18-350,700,1050 60kHz Internal Operating Frequency RACT18-500 64kHz RACT18-1400 65kHz RACT18-350 150mA RACT18-500 200mA (1) Output Ripple Current RACT18-700 260mA RACT18-1050 700mA RACT18-1400 560mA Notes: Note1: Measured at 20MHz BW by using a 12 twisted pair-wie terminated with a 0.1F and 47F capacitor parallel across output REGULATIONS Parameter Condition Value Output Accuracy 5% typ. Load Regulation 5% max. Line Regulation 5% max. PROTECTION Parameter Condition Value Input Fuse fusible resistor Short Circuit Protection (SCP) Latch OFF, auto recovery after fault condition is removed RACT18-350 60VDC max. RACT18-500 43VDC max. Latch OFF, auto recovery Over Voltage Protection (OVP) RACT18-700 33VDC max. after fault condition is removed RACT18-1050 24VDC max. RACT18-1400 22VDC max. Over Load Protection (OLP) Latch OFF, auto recovery after fault condition is removed Over Temperature Protection (OTP) 110C Latch OFF, auto recovery after fault condition is removed Isolation Voltage I/P to O/P tested for 1 minute 3.75kVAC Leakage Current 5mA max. Maximum loading of automatic circuit breakers* * 230VAC, 1Ohm, 90 phase angle and max. load Circuit Breaker Circuit Breaker Current Typ 10A 16A 20A 25A B 24 38 46 58 C 38 62 74 92 ENVIRONMENTAL Parameter Condition Value Operating Temperature Range without derating natural convection 0.1m/s (see graph) -20C to +50C Max. Case Temperature at tc point +80C max. Operating Humidity non-condensing 5-85% RH IP Rating IP20 Pollution Degree PD2 Design Lifetime +25C ambient >30 x 10 hours continued on next page www.recom-power.com REV.: 4/2020 L-2