4W AC-DC class II LED power supply 12V and 24V constant voltage output Features Fully protected (OLP, SCP, OCP, OTP) AC/DC Converter Low standby power, ErP conform IP65 (suitable for dry and damp locations) LED Low cost CE, CB, ENEC, CSA and UL8750 certified Driver RACV04 Wired connections for independent or built-in use Description 4 Watt These constant voltage LED drivers have been designed for cost-sensitive applications. The SELV Constant outputs are suitable for built-in power-supply LED luminaires. Their low profile design allows them to be invisibly built into furniture, discreetly mounted under shelves or integrated in space-restricted Voltage Single applications such as coving lighting, strip lighting or troffer lighting systems. The power supplies are short circuit and overload protected and come with a full 3-year warranty. Output Selection Guide Part Input Input Output Output Efficiency Output Number Voltage Range Current Voltage Current Range typ. Power max. VAC mA VDC mA % W RACV04-12 90-264 100 12 0-330 75 4 RACV04-24 90-264 100 24 0-170 75 4 All LED Drivers may not be used without a load. They must be switched on the primary side only. Noncompliance may damage the LED or reduce its lifetime. ERP compliant Model Numbering RACV04- nom. Output Power Output Current Specifications (measured ta= 25C, 240VAC and rated load) UL8750 Certified BASIC CHARACTERISTICS CSA C22.2 No. 250.13 Certified IEC/EN61347-1 Certified Parameter Condition Min. Typ. Max. IEC/EN61347-2-13 Certified Input Voltage Range 90VAC 230VAC 264VAC IEC62384 Certified Inrush Current 11A EN55015 Compliant Start-up Time 500ms ENEC CB Report Input Frequency Range 47Hz 63Hz No Load Power Consumption 0.5W Power Factor full load, 230VAC 0.40 Internal Operating Frequency full load 64kHz 12VDC 120mVp-p (1) Output Ripple Voltage 24VDC 240mVp-p Notes: Note1: Measured at 20MHz BW using 0.1F & 47F parallel capacitor. www.recom-power.com REV.: 2/2019 L-1RACV04 AC/DC Converter Series Specifications (measured Ta= 25C, 240VAC and rated Iout) REGULATIONS Parameter Condition Value Output Voltage Accuracy 5% max. Line Regulation 5% max. Load Regulation 5% max. PROTECTION Parameter Condition Value Input Fuse external fuse is recommended 0.22W fusible resistor Open Circuit Protection (OCP) auto recovery after fault condition is removed Over Load Protection (OLP) auto recovery after fault condition is removed Over Voltage Protection (OVP) auto recovery after fault condition is removed Over Temperature Protection (OTP) 110C Tcase auto recovery after fault condition is removed (2) Isolation Voltage I/P to O/P 3.75kVAC / 1 minute Isolation Resistance 100MW Notes: Note2: For repeat Hi-Pot testing, reduce the time and/or the test voltage Maximum loading of automatic circuit breakers 115VAC, 1Ohm, 90 phase angle and max. load 230VAC, 1Ohm, 90 phase angle and max. load Circuit Breaker Circuit Breaker Current Circuit Breaker Circuit Breaker Current Typ 10A 16A 20A 25A Typ 10A 16A 20A 25A C 54 118 148 184 B 17 28 35 44 C 27 59 74 92 ENVIRONMENTAL Parameter Condition Value Operating Temperature Range -20C to +50C Maximum Case Temperature +79C Operating Altitude 2000m Operating Humidity 5% to 85% RH, non condensing IP Rating IP65 Pollution Degree PD2 Design Lifetime 30 x 10 hours Derating Graph 100 90 80 70 60 50 40 30 20 10 0 -20 -10 0 10 20 30 40 50 60 Ambient Temperature C www.recom-power.com REV.: 2/2019 L-2 Output Load %