C C S S O O R R E E M M T T P P R R L L I I E E A A V V N N N N T T NOT RECOMMENDED FOR NEW DESIGNS TH (LAST TIME BUY: 30 Oct 2020) 2 and 3-phase operation Features Input voltage range: 320 575VAC Output trim range: 22.5 29.5VDC AC/DC Converter High electrical strength high reliability DIN-Rail Permanent overload and short-circuit protection Parallel operation capability Series REDIN120/3AC International safety certification listing Description 120 Watt 5 The REDIN/3AC is a series of rugged DIN rail power supplies for two and three-phase mains 3 Phase operation from 320 to 575VAC without the need of a neutral connection. Four versions with a maximum current limited output deliver 5A, 10A, 20A or 40A without derating up to +55C. The output DIN-Rail can be grounded via a third common output terminal. The LED signal on the front panel indicates that the output voltage remains within the wide adjustable range from 22.5 to 29.5VDC. The units are covered by international safety certificates and are intended for worldwide use. In power-hungry applications, the Power Supply units can be connected in parallel with no need for additional components. Selection Guide (1) Part nom. Input Output Output Rated Efficiency Number Voltage Range Voltage Adjustability Current typ. VAC VDC VDC A % REDIN120-24/3AC 400 - 500 24 22.5 - 29.5 5 89 Notes: Note1: Efficiency is tested at nominal input and full load at +25C ambient Model Numbering 2+ RoHS REDIN120-24/3AC REACH compliant compliant 10 from 10 nom. Output Power Output Voltage Specifications (measured Ta= 25C, nom.Vin, full load and after warm-up unless otherwise stated) E196683 E470721 BASIC CHARACTERISTICS UL60950-1 certified Parameter Condition Min. Typ. Max. UL508 certified 3 phase operation 320VAC 400VAC 575VAC EN60950-1 certified Input Voltage Range 2 phase operation 360VAC 400VAC 575VAC CSA C22.2 No. 60950-01 certified 400VAC 3 x 300mA EN55011 compliant 3 phase operation EN50121-4 compliant 500VAC 3 x 300mA Input Current CSA C22.2 No.107 certified 400VAC 2 x 650mA 2 phase operation EN61000-6-2 compliant 500VAC 2 x 500mA EN61000-6-3 compliant Inrush Current 15A Return Voltage Immunity 24Vout 35VDC No Load Power Consumption 4W Input Frequency Range 45Hz 65Hz Output Voltage Trimming 22.5VDC 29.5VDC Minimum Load 0% Start-up time 2/3 phase operation, 400VAC 1s Rise time 2ms 400VAC 20ms Hold-up time 480VAC 30ms Output Ripple & Noise measured at 20MHz BW 30mVp-p continued on next page www.recom-power.com REV.: 3/2020 PDR-1 O O P P C C R R O O M M D D O O U U C C C C E E T T R R S STH (LAST TIME BUY: 30 Oct 2020) NOT RECOMMENDED FOR NEW DESIGNS REDIN120/3AC AC/DC Converter Series Specifications (measured Ta= 25C, nom.Vin, full load and after warm-up unless otherwise stated) Efficiency vs. Load 3 Phase Operation Power Dissipation vs. Load 3 Phase Operation 18 100 16 90 14 80 12 70 10 60 8 50 6 360VAC 40 400VAC 4 360VAC 480VAC 30 400VAC 2 480VAC 20 0 0 10 20 30 40 50 60 70 80 90 100 10 Output Load % 0 0 10 20 30 40 50 60 70 80 90 100 Output Load % REGULATION Parameter Condition Value Output Accuracy 1.0% max. Line Regulation 10% change in input voltage 0.1% typ. Load Regulation 10% - 100% load 1.0% typ 2.0% max. 25% load step change 200mV typ. Transient Response recovery time 50ms typ. Deviation vs. Load 1 0.75 0.5 0.25 0 -0.25 -0.5 -0.75 -1 0 10 20 30 40 50 60 70 80 90 100 Output Load % PROTECTIONS Parameter Type Value (2) Input Fuse internal F4A, fast blow 3x 6A (charactersitics B) Recommended backup fuse for mains protection 3x 10A (charactersitics B) 3x 16A (charactersitics B) Short Circuit Protection (SCP) below 100m >120% typ. power limiting Over Voltage Protection (OVP) >145% typ. auto recovery Over Voltage Category (OVC) OVC II continued on next page www.recom-power.com REV.: 3/2020 PDR-2 Efficiency % Deviation % Power Dissipation W