C C S S O O R R w E E M M T T P P R R a L L R I I E E A A r V V N N A N N T T r NOT RECOMMENDED FOR NEW DESIGNS TH (LAST TIME BUY: 27 NOV 2020) Universal AC input (85-264VAC) Features Long 7 year warranty Protections: SCP, OVP, OCP, OTP AC/DC Converter 100% full load burn-in test DC OK indicator LED with relay contacts DIN Rail Cooling by free air convection, 5000m operation Series REDIN60 UL, CSA & CE certified with CB report Description 60 Watt 7 This DIN-rail mounted power supply uses high reliability components to give a long, trouble-free life. DIN-Rail The power supply can be end mounted to save space or side mounted for use in low-profile cabi- nets. Relay contacts simplify DC OK monitoring and the units can deliver 80W start-up power. Power Supply The REDIN series is fully certified for industrial use and carries a 7-year warranty. Selection Guide Part Input Output Output Rated Efficiency Max. Number Voltage Range Voltage Trimming Voltage Current typ. Capacitive Load VAC VDC VDC A % F REDIN60-12 85-264 12 12-15 5.0 85 18800 REDIN60-24 85-264 24 24-28 2.5 86 4700 Specifications (measured at Ta= 25C, 230VAC, full load and after warm up) 22 RoHSRoHS BASIC CHARACTERISTICS REACHREACH compliantcompliant compliantcompliant 6 from 66 from 6 2011/65/EU2011/65/EU Parameter Condition Min. Typ. Max. Input Voltage Range all operating conditions 85VAC 264VAC 300VAC max. Input Voltage max. 1 second 375VDC E224736 Output Voltage Adjustment REDIN60-12 12-15VDC (12V5%) CB-Report (1) (Factory Setting) REDIN60-24 24-28VDC (24V5%) UL60950-1 certified full load, 115VAC 1.8A IEC/EN60950-1 certified Input Current full load, 230VAC 1.0A CSA C22.2 No. 60950-1-07 certified cold start at 25C, 115VAC 40A UL508 certified Inrush Current cold start at 25C, 230VAC 60A CAN/CSA-C22.2 No. 107.1-01 certified EN55024 certified standard (with Relay) <1000mW No Load Power Consumption EN55032 certified /NR option (no Relay) <500mW Start up time cold start, 230VAC 500ms 1000ms Rise time cold start, 230VAC 20ms SEARCHING FOR full load, 115VAC 20ms ALTERNATIVES Hold-up time full load, 230VAC 50ms Contact RECOM Input Frequency Range 47Hz 63Hz TH (LAST TIME BUY: 27 NOV 2020) NOT RECOMMENDED FOR NEW DESIGNS REDIN60 AC/DC Converter Series Specifications (measured at Ta= 25C, 230VAC, full load and after warm up) Efficiency vs. Load REDIN60-12 REDIN60-24 100 100 90 90 80 80 70 70 60 60 50 50 40 40 30 85VAC 30 85VAC 115VAC 115VAC 20 20 230VAC 230VAC 264VAC 264VAC 10 10 0 0 0 10 20 30 40 50 60 70 80 90 100 0 10 20 30 40 50 60 70 80 90 100 Output Load % Output Load % Vadj. Derating 100 80 60W max. Vadj. 12 15 (24) (28) Output Voltage VDC REGULATION Parameter Condition Value Line Regulation 0.1% typ. / 1% max. Load Regulation 0.1% typ. / 1% max. (3) Transient Response REDIN60-12 (step load change: 2.5A - 5.0A) 5% typ. REDIN60-24 (step load change: 1.25A - 2.5A) 5% typ. Dwell Time 100Hz & 1kHz 50% duty Slew Rate 0.5A / s Notes: Note3: Transient Response + E-CAP loading 3300F. Other specs with resistive load only PROTECTION Parameter Condition Value Input Fuse T2.5A, slow blow type Short Circuit Protection (SCP) auto-recovery after fault condition, Hiccup Mode REDIN60-12 18VDC max., shut-down latch-off o/p voltage, re-power on to recover Over Voltage Protection (OVP) REDIN60-24 35VDC max., shut-down latch-off o/p voltage, re-power on to recover Over Voltage Category OVCII Over Current Protection (OCP) 150% typ., auto-recovery after fault condition is removed Over Temperature Protection (OTP) detect on inside ambient 105C5%, shut-down latch-off o/p voltage, re-power on to recover I/P to O/P 3.75kVAC Isolation Voltage tested for 1 minute I/P to FG 1.88kVAC O/P to FG 0.5kVAC Isolation Resistance 500VDC, 70% RH, I/P to O/P I/P to FG O/P to FG 100MW min. Leakage Current 240VAC >1mA Relay Contacts 1A, 30VDC / 120VAC Power OK LED LED/Relay ON if Vout = 11-16V (12V) / 22-30V (24V) www.recom-power.com REV.: 10/2020 PDR-2 Efficiency % Output Current % Efficiency %