High 6.4kVDC/1s isolation Features Wide operating temperature range from DC/DC Converter -40C to +90C without derating High capacitive load capability Unregulated Continuous short circuit protection Converters Efficiency up to 80% RK/H6 & RH/H6 Description 1 Watt The RK/H6 and RH/H6 series 1W DC/DC converters feature high 6.4kVDC isolation and an extended SIP7 operating temperature range up to +90C without derating, yet are lower cost than standard high isolation converters. They are suitable for demanding industrial and high isolation test and measurement Single and Dual applications. Output Selection Guide Part nom. Input Output Output Efficiency Max. Capacitive (1) Number Voltage Range Voltage Current typ. Load VDC VDC mA % F RK-xx3.3S/H6 5, 12, 15, 24 3.3 303 71-74 1000 RK-xx05S/H6 5, 12, 15, 24 5 200 74-77 1000 RK-xx12S/H6 5, 12, 15, 24 12 84 77-79 220 RK-xx15S/H6 5, 12, 15, 24 15 66 77-80 220 RH-xx3.3D/H6 5, 12, 15, 24 3.3 152 73-74 330 RH-xx05D/H6 5, 12, 15, 24 5 100 74-77 330 RH-xx12D/H6 5, 12, 15, 24 12 42 77-80 100 RH-xx15D/H6 5, 12, 15, 24 15 33 78-80 100 Notes: Note1: Max. capacitive load is tested at nominal input voltage and full load Model Numbering E224736 RK- S/H6 UL60950-1 certified CAN/CSA C22.2 No. 60950-1-07 certified 6.4kVDC isolation Input Voltage UL62368-1 certified Single Output Voltage CAN/CSA C22.2 No. 62368-1-14 certified IEC/EN60950-1 certified IEC/EN62368-1 certified CB report RH- D/H6 6.4kVDC isolation Input Voltage Dual Output Voltage Notes: Note2: add suffix K for Single output or suffix H for Dual output Ordering Examples: RK-123.3S/H6 = 12VDC Input Voltage, 3.3VDC Output Voltage, Single Output, 6.4kVDC/1s isolation RH-0505D/H6 = 5VDC Input Voltage, 5VDC Output Voltage, Dual Output, 6.4kVDC/1s isolation www.recom-power.com REV.: 5/2019 ECO-1RK/H6 & RH/H6 DC/DC Converter Series Specifications (measured Ta= 25C, nom. Vin, full load and after warm-up unless otherwise stated) BASIC CHARACTERISTICS Parameter Condition Min. Typ. Max. Internal Input Filter capacitor Input Voltage Range 10% Start-up Time 20ms Internal Operating Frequency 80kHz Minimum Load 0% Output Ripple and Noise 20MHz BW 60mVp-p 120mVp-p Efficiency vs. Load Single Output Dual Output 100 100 90 90 80 80 70 70 60 60 50 50 40 40 30 30 RK-123.3S/H6 RH-123.3D/H6 RK-0505S/H6 RH-0505D/H6 20 20 RK-0512S/H6 RH-1212D/H6 10 10 RK-2415S/H6 RH-0515D/H6 0 0 0 10 20 30 40 50 60 70 80 90 100 0 10 20 30 40 50 60 70 80 90 100 Output Load % Output Load % REGULATIONS Parameter Condition Values Output Accuracy 5.0% max. Line Regulation low line to high line, max. load 1.2% of 1.0% Vin typ. (3) Load Regulation 10% to 100% load 10% max. Notes: Note3: Operation below 10% load will not harm the converter, but specifications may not be met Deviation vs. Load Single Output Dual Output 20 20 15 15 10 10 5 5 0 0 -5 -5 RK-123.3S/H6 RH-123.3D/H6 -10 -10 RK-0505S/H6 RH-0505D/H6 RK-0512S/H6 RH-1212D/H6 -15 -15 RK-2415S/H6 RH-0515D/H6 -20 -20 0 10 20 30 40 50 60 70 80 90 100 0 10 20 30 40 50 60 70 80 90 100 Output Load % Output Load % www.recom-power.com REV.: 5/2019 ECO-2 Deviation % Efficiency % Deviation % Efficiency %