Inside US: +1 (877) 432-9908 Bulletin No. GMDIO-H Outside US: +1 (717) 767-6511 Drawing No. LP0921 www.redlion.net Released 2017-03-30 ModelGMDIOGraphiteDigitalModule ADDS I/O CAPABILITY TO THE GRAPHITE PRODUCTS EIGHT INPUT, SIX OUTPUT DIGITAL MODULE INPUTS ISOLATED FROM OUTPUTS INPUTS INDEPENDENTLY SWITCH SELECTABLE FOR SINK OR SOURCE SIGNALS INPUTS INDEPENDENTLY CONFIGURABLE FOR HIGH OR LOW ACTIVE STATE INPUTS INDEPENDENTLY SWITCH SELECTABLE FOR HIGH OR LOW FREQUENCY SIGNALS RELAY OR NFET OUTPUT MODELS AVAILABLE U R C L US LISTED IND. CONT. EQ. 34AD FOR USE IN HAZARDOUS LOCATIONS: U C R L US II 3 G Ex nA IIC T4 Gc Class I, Division 2, Groups A, B, C, and D -40C T 75C T4 AMB LISTED DEMKO 14 ATEX 1387X IND.CONT. EQ. 3PWL IECEx UL 15.0035X ForModelNo.GMDIOS00Only ForModelNo.GMDIOS00Only Once programmed, the module will continue to operate/control GENERALDESCRIPTION independent of the Graphite host device as long as power is applied. The Model GMDIO14 module is a digital I/O module designed for use Remove power from the host device before installing or replacing any with the Graphite products. This module offers eight inputs and six modules. outputs that can be used to monitor contact or sensor inputs and actuate relays, solenoids, PLC inputs, etc. The inputs accept standard DC inputs or contact closures, and are CONFIGURATION configured for Sink/Source signals via external switches. Additionally, The Graphite is configured with Windows compatible Crimson each input has a switch selectable input filter that can be used to prevent software. The software is an easy to use, graphical interface which contact bounce. Each input may also be software configured as a high- provides a means of configuration and commissioning of new systems, active or low-active input. as well as routine module re-calibration. The module is available with relay or NFET outputs that are capable of switching up to one amp each (NFET DC only). For applications requiring large loads to be controlled, several DIN rail mount relays are SAFETYSUMMARY available. All safety related regulations, local codes and instructions that appear The modules connect and communicate via proprietary USB in this literature or on equipment must be observed to ensure personal connection to the various Graphite host devices. The Graphite host safety and to prevent damage to either the instrument or equipment devices, equipped with serial ports as well as an Ethernet port(s), allows connected to it. If equipment is used in a manner not specified by the the system to share data with PCs, PLCs, and SCADA systems. The manufacturer, the protection provided by the equipment may be maximum number of modules varies for each Graphite host device, see impaired. specific models for details. Do not use this unit to directly command motors, valves, or other actuators not equipped with safeguards. To do so can be potentially harmful to persons or equipment in the event of a fault to the unit. DIMENSIONSIninches(mm) DIMENSIONS2.97 (76) Ininches(mm) WARNING -CAUTION: Ris EXPLk ofOSION HAZ Danger. ARD - DO NOT D 1.25 (32) EQUIRead coPMEmplNT UNLete insESS POtructionsWER HAS BE prior to installEN SWation OR AREand operAat ISion KoNf theOWN TO BE NON unit. -HAZARDOU WARNING -WARNING - EEXPLXPLOSION HAZOSION HAZAARD - DO NOTRD - DO NOT DDIISSCCONNEONNECT CT EQUIEQUIPMEPMENNT UNLT UNLESS POESS POWER HAS BEWER HAS BEEN SWIEN SWITTCHECHED OFF D OFF OR AREOR AREAA IS IS KKNNOWN TO BE NONOWN TO BE NON--HAHAZARDOZARDOUS.US. 4.65 WARNING - EXPLOSION HAZARD - SUBSTITUTION OF COMPONENTS MAY IMPAIR SUITABILITY FOR CLASS I, (118) DIVISION 2. -1-Bulletin No. GMDIO-H Released 2017-03-30 Drawing No. LP0921 7. COMMUNICATIONS: Provided by the Graphite host device GENERALSPECIFICATIONS 8. ENVIRONMENTAL CONDITIONS: 1. POWER: Power will be supplied by the Graphite host device. Some Operating Temperature Range: modules, depending on usage may consume high levels of power. This GMDIOR00: -40 to 70 C may limit the total number of modules that can be installed on a single GMDIOS00: -40 to 75 C Graphite host. Check the Graphite module and Graphite host data Operating temperature is limited to lowest range among equipment sheets for specific usage and power requirements. used in your Graphite system. Consult the user manual or GMDIO14 Max Power: 3.6 W www.redlion.net/OpTemp for further details. 2. LEDs: Storage Temperature Range: -40 to +85 C STS - Status LED shows module condition. Shock to IEC 68-2-27: Operational 40 g (10 g, modules w/relays) IN1-IN8 - LEDs are lit when associated input is active. Operating and Storage Humidity: 85% max. Relative humidity, non- OP1-OP6 - LEDs are lit when associated output is active. condensing 3. MEMORY: Non-volatile memory retains all programmable parameters. Altitude: Up to 2000 meters 4. INPUTS: DIP switch selectable for sink or source 9. CERTIFICATIONS AND COMPLIANCES: Maximum voltage: +30 VDC, reverse polarity protected CE Approved Off Voltage: < 1.2 Volts EN 61326-1 Immunity to Industrial Locations On Voltage: > 3.8 Volts IEC/EN 61010-1 Input Impedance: Source Mode 10K ohms Sink Mode 20K ohms RoHS Compliant Input Frequency*: ATEX Approved (GMDIOS00 only) Filter switch on: 50 Hz II 3 G Ex nA IIC T4 Gc Filter switch off: 300 Hz DEMKO 14 ATEX 1387X * Actual useable frequency limited by communication to external EN 60079-0, -15 device. IECEx Approved (GMDIOS00 only) 5. OUTPUTS: Outputs available as FORM-A relay or Solid State NFET. Ex nA IIC T4 Gc Form A Relay Output: IECEx UL 15.0035X Type: N.O. IEC 60079-0, -15 The following pairs of relays share the common terminal: 1&2, 3&4, UL Listed: File E302106 5&6 UL Hazardous: File E317425 (GMDIOS00 only) Current Rating by pair: 3 Amps 30 VDC / 125 VAC resistive ABS Type Approval for Shipboard Applications 1/10 HP 125 VAC 10.CONSTRUCTION: Case body is all metal construction. Life Expectancy: 200,000 cycles at maximum load rating. 11.CONNECTIONS: Removable wire clamp screw terminal blocks (Decreasing load, increasing cycle time, and use of surge Wire Gage: 28-16 AWG (0.32 mm - 1.29 mm) terminal gage wire suppression such as RC snubbers increases life expectancy.) Torque: 1.95-2.21 inch-lbs (0.22-0.25 N-m) Solid State Output: 12.MOUNTING: Screws to host Type: Switched DC, N Channel open drain MOSFET 13.WEIGHT: 8 oz (224 g) Contact Rating: 1 ADC max VDS ON: < 0.2 V 1 A VDS MAX: 30 VDC Offstate Leakage Current: 0.5 mA max 6. ISOLATION LEVEL: 500 Vrms 50/60 Hz for 1 minute between the following: Inputs Outputs Graphite Host Power Supply Input Block Diagram ISOLATED ISOLATED ISOLATED ISOLATED PORT 1 1 1 PROGRAMMING 1 1 2 COM 1,2 A COM INPUTS INPUTS 1,2 NFET 3 4 OUTPUTS 2 PORT 2 COM 3,4 3 8 8 COMMUNICATIONS 5 RELAY COM 3,4 6 OUTPUTS A C COM 5,6 E 4 5 ISOLATED D PORT 3 COM 5,6 ETHERNET 6 B F + POWER POWER POWER VDC SUPPLY SUPPLY SUPPLY - A GMDIOS00 GMDIOR00 GRAPHITE HOST -2-