Bulletin No. MLPS1-D Drawing No. LP0582 Released 03/10 Tel +1 (717) 767-6511 Fax +1 (717) 764-0839 www.redlion.net MODEL MLPS1 and MLPS2 - MICRO-LINE POWER SUPPLIES PROVIDES POWER FOR THE MICRO-LINE SERIES MLPS1: 12 VDC OUTPUT 400 mA MLPS2: 24 VDC OUTPUT 200 mA EASILY ATTACHED TO BACK OF DT8, CUB4 AND CUB5 UL Recognized Component, File E179259 DESCRIPTION SPECIFICATIONS The Model MLPS power supplies are designed to attach to the rear of the 1. POWER REQUIREMENTS: 85-250 VAC, 50/60 Hz, 14 VA. 2. POWER OUTPUT: Micro-Line Series. The MLPS1 provides a 12 VDC output, while the MLPS2 MLPS1: +16 VDC max 4 mA 11.5 VDC min 400 mA provides a 24 VDC output. Both supplies can be powered from an 85-250 VAC MLPS2: +26 VDC max 0 mA 22 VDC min 200 mA source. 3. ENVIRONMENTAL CONDITIONS: Caution: The maximum output current of the MLPS1 is 400 mA and the MLPS2 Operating Temperature: 0 to 60C is 200 mA. Check the specifications of the specific counter(s)/indicators(s) Storage Temperature: -30 to 75C and sensors(s) being used to ensure that total current requirements do not Operating and Storage Humidity: 85% max. (non-condensing) from 0C exceed the respective values of the power supplies. to 50C. Altitude: Up to 2000 meters SAFETY SUMMARY 4. CERTIFICATIONS AND COMPLIANCES: All safety related regulations, local codes and instructions that appear in the SAFETY UL Recognized Component, File E179259, UL61010-1, CAN/CSA- manual or on equipment must be observed to ensure personal safety and to C22.2 No. 61010-1 prevent damage to either the instrument or equipment connected to it. If Recognized to U.S. and Canadian requirements under the Component equipment is used in a manner not specified by the manufacturer, the protection Recognition Program of Underwriters Laboratories, Inc. provided by the equipment may be impaired. Output meets Class 2 power requirements per UL 1310. IECEE CB Scheme Test Report E179259-V2-S1 Issued by Underwriters Laboratories, Inc. IEC 61010-1, EN 61010-1: Safety requirements for electrical equipment for measurement, control, and laboratory use, Part 1. CAUTION: Risk of Danger. CAUTION: Risk of electric shock. ELECTROMAGNETIC COMPATIBILITY Read complete instructions prior to Emissions and Immunity to EN 61326: Electrical Equipment for installation and operation of the unit. Measurement, Control and Laboratory use. Immunity to Industrial Locations: Electrostatic discharge EN 61000-4-2 Criterion A DIMENSIONS In inches (mm) 4 kV contact discharge A. SEE APPROPRIATE LITERATURE 8 kV air discharge FOR UNIT DIMENSIONS EXISTING PANEL B. CUB5 - 2.96 (75.2) Electromagnetic RF fields EN 61000-4-3 Criterion A MOUNTING CLIP CUB4, DT8 - 2.60 (66.0) 10 V/m Fast transients (burst) EN 61000-4-4 Criterion A MLPS UNIT 2.65 (67.3) 2 kV power 1 kV signal Surge EN 61000-4-5 Criterion B 1 kV L-L, B 2 kV L&N-E power 1 kV signal RF conducted interference EN 61000-4-6 Criterion A DC COMMON +12V 3 V/rms RED LION CONTROLS Voltage dip/interruptions EN 61000-4-11 Criterion A YORK, PA. MADE IN U.S.A. 1.85 (47) MODEL MLPS1 0.5 cycle INPUT POWER: 85-250 VAC, 50/60Hz, 14VA AC INPUT OUTPUT POWER: TERMINAL 12VDC UNREG. 400mA Emissions: OPERATING TEMP: 0 TO 60C A EN 55011 Class B Notes: 1.30 (33) 1. Criterion A: Normal operation within specified limits. 2. Criterion B: Temporary loss of performance from which the unit self- recovers. ORDERING INFORMATION 5. CONSTRUCTION: High impact black plastic. Mounting hardware included. Installation Category II, Pollution Degree 2. MODEL NO. DESCRIPTION PART NUMBER 6. CONNECTION: Two position terminal block which accepts one 14 AWG MLPS1 +12 VDC Micro Line/Sensor Power Supply MLPS1000 wire (torque terminal screws to 5 inch-lbs. 0.56 N-m ). 7. WEIGHT: 2 oz (47 g) MLPS2 +24 VDC Micro Line/Sensor Power Supply MLPS2000 M3424BDC COMMON +12V RED LION CONTROLS YORK, PA. MADE IN U.S.A. MODEL MLPS1 INPUT POWER: 85-250 VAC, 50/60Hz, 7VA AC INPUT OUTPUT POWER: TERMINAL 12VDC UNREG. 400mA M3424X OPERATING TEMP: 0 TO 60C DC COMMON +24V RED LION CONTROLS YORK, PA. MADE IN U.S.A. MODEL MLPS2 INPUT POWER: 85-250 VAC, 50/60Hz, 14VA AC INPUT OUTPUT POWER: TERMINAL 24VDC UNREG. 200mA M4274X OPERATING TEMP: 0 TO 60C INSTALLATION ENVIRONMENT The unit should be installed in a location that does not exceed the maximum operating temperature and provides good air circulation. Placing TROUBLESHOOTING the unit near devices that generate excessive heat should be avoided. For further technical assistance, contact technical support at the appropriate company numbers listed. Installation Procedure The MLPS is shipped with all the necessary hardware to mount to the rear of an installed Micro-Line unit. Refer to the instructions that correspond to your Micro-Line unit for proper installation. CUB4, DT8 The user must remove the common and V+ screw terminals on the rear of the Micro-Line unit. Install the 1/4 hex drive stand-offs into the common and V+ terminals. The MLPS is then mounted to the stand-offs using the screw terminals and square washers. AC power can then be connected to the terminal block of the MLPS. EXISTING PANEL MOUNTING CLIP SQUARE WASHER BEZEL GASKET STAND-OFF (2 TYP) CUB5 The user must remove the common and V+ SCREW TERMINALS screw terminals on the rear of the Micro-Line unit. Install the 3/16 hex drive stand-offs into the common and V+ terminals. The MLPS is then mounted to the stand-offs using the supplied screws and square washers. AC power can then be connected to the terminal block of the MLPS. EXISTING PANEL MOUNTING CLIP BEZEL GASKET SQUARE WASHERS STAND-OFF (2 TYP) SCREW TERMINALS Red Lion Controls Red Lion Controls India China Red Lion Controls Red Lion Controls 54, Vishvas Tenement Unit 101, XinAn Plaza Headquarters Europe GST Road, New Ranip, Building 13, No.99 Tianzhou Road 20 Willow Springs Circle Printerweg 10 Ahmedabad-382480 Gujarat, India ShangHai, P.R. China 200223 York PA 17406 NL - 3821 AD Amersfoort Tel +91 987 954 0503 Tel +86 21 6113-3688 Tel +1 (717) 767-6511 Tel +31 (0) 334 723 225 Fax +91 79 275 31 350 Fax +86 21 6113-3683 Fax +1 (717) 764-0839 Fax +31 (0) 334 893 793