MT-PI-... installation relays MT-PI-...-11-... MT-PI-...-22-... Installation relays - electromagnetic AC, DC and AC/DC coils Cover - installation module, width 17,5 mm Load of AC1 up to 16 A / 250 V (versions 1 CO, 1 NO ) and up to 8 A / 250 V (versions 2 CO, 2 NO) Light indicator (LED diode) - supply voltage Application: automatic systems in buildings - in cooperation with control timers, switches, control switches electric systems industrial automation and power engineering automation switchgears of modular equipment Recognitions, certifications, directives: Contact data Number and type of contacts 1 CO, 1 NO 2 CO, 2 NO Contact material AgNi Max. switching voltage 400 V AC / 300 V DC Min. switching voltage 5 V Rated load AC1 16 A / 250 V AC 8 A / 250 V AC DC1 16 A / 24 V DC 8 A / 24 V DC Min. switching current 5 mA Max. inrush current 30 A 15 A Rated current 16 A 8 A Max. breaking capacity AC1 4 000 VA 2 000 VA Min. breaking capacity 0,3 W Contact resistance 100 m Max. operating frequency at rated load AC1 600 cycles/hour no load 72 000 cycles/hour Coil data Rated versions 1 CO, 2 CO 50/60 Hz AC 115 ... 230 V voltage DC 12 ... 48 V versions 1 NO, 2 NO 50 Hz AC 230 V AC: 50 Hz AC/DC 12 ... 115 V Must release voltage AC: 0,15 Un DC: 0,05 Un Operating range of supply voltage 0,85...1,1 Un AC: 50/60 Hz see Tables 1, 2, 3, 4 Rated versions 1 CO, 2 CO AC 1,0 VA 115 V AC, 230 V AC, AC: 50 Hz power DC 0,5 W 12 V DC consumption DC 0,65 W 24 V DC, 48 V DC versions 1 NO, 2 NO AC 0,5 VA 230 V AC, AC: 50 Hz AC/DC 0,75 VA / 0,75 W 12 V AC/DC, AC: 50 Hz AC/DC 0,65 VA / 0,65 W 24 V AC/DC, 48 V AC/DC, 115 V AC/DC, AC: 50 Hz Insulation according to PN-EN 60664-1 Insulation rated voltage 250 V AC Rated surge voltage 4 000 V 1,2 / 50 s Overvoltage category II Insulation pollution degree 1 Flammability degree contact plate: V-0 cover: V-1 UL94 Dielectric between coil and contacts 3 000 V AC contacts 1 CO and 2 CO, type of insulation: basic strength 4 000 V AC contacts 1 NO and 2 NO, type of insulation: reinforced contact clearance 1 000 V AC type of clearance: micro-disconnection pole - pole 2 000 V AC contacts 2 CO, type of insulation: basic 2 500 V AC contacts 2 NO, type of insulation: basic General data Operating / release time (typical values) 15 ms / 20 ms 7 Mechanical life (cycles) > 10 Dimensions (L x W x H) 90 x 17,5 x 63,5 mm Weight 60 g 65 g o Ambient temperature storage -40...+70 C o operating -20...+45 C Cover protection category IP 20 PN-EN 60529 Relative humidity up to 90% Shock resistance 15 g Vibration resistance (NO/NC) 9 g / 5 g 10...150 Hz The data in bold type pertain to the standard versions of the relays. UL only for 15 A. Length with 35 mm rail taps: 98,8 mm. 1 www.relpol.com.pl Export Sales Department phone +48 68 47 90 832, 951 e-mail: export relpol.com.pl 14.07.2014MT-PI-... installation relays Coil data - DC voltage version (1 CO, 2 CO contacts) Table 1 Coil operating range Coil operating range Coil code V DC V DC min. (at 20 C) max. (at 55 C) 1012 12 10,2 13,2 1024 24 20,4 26,4 1048 48 40,8 52,8 Coil data - AC 50/60 Hz voltage version (1 CO, 2 CO contacts) Table 2 Coil operating range Coil operating range Coil code V AC V AC min. (at 20 C) max. (at 55 C) 5115 115 97,8 126,5 5230 230 195,5 253,0 Coil data - AC/DC 50 Hz voltage version (1 NO, 2 NO contacts) Table 3 Coil operating range Coil operating range Coil code V AC/DC V AC/DC min. (at 20 C) max. (at 55 C) 8012 12 10,2 13,2 9024 24 V AC/DC 20,4 26,4 230 V AC 195,5 253,0 8048 48 40,8 52,8 8115 115 97,8 126,5 Selection of supply voltage via wires connection: 24 V AC/DC - to the terminals A1-A2 230 V AC - to the terminals A1-A3. Dimensions 1 CO 1 NO 2 CO 2 NO PRECAUTIONS: 1. Ensure that the parameters of the product described in its specification provide a safety margin for the appropriate operation of the device or system and never use the product in circumstances which exceed the parameters of the product. 2. Never touch any live parts of the device. 3. Ensure that the product has been connected correctly. An incorrect connection may cause malfunction, excessive heating or risk of fire. 4. In case of any risk of any serious material loss or death or injuries of humans or animals, the devices or systems shall be designed so to equip them with double safety system to guarantee their reliable operation. 2 www.relpol.com.pl Export Sales Department phone +48 68 47 90 832, 951 e-mail: export relpol.com.pl 14.07.2014