R15 - 2 CO, 3 CO industrial relays of small dimensions Relays of general application For plug-in sockets: 35 mm rail mount acc. to PN-EN 60715 on panel mounting solder terminals Contacts AgNi Coils AC and DC WT (mechanical indicator + lockable front test button) - standard features of relays in cover, for plug-in sockets. Relays may be provided with the test buttons (no latching) and plugs - page 6 Have obtained LR Type Approval Certifi cate (Lloyds R15 - 2 CO R15 - 3 CO Register) Recognitions, certifi cations, directives: RoHS, AUCOTEAM GmbH Berlin - railroad standard, Contact data Number and type of contacts 2 CO, 3 CO Contact material AgNi, AgNi/Au 0,2 m, AgNi/Au 5 m Rated / max. switching voltage AC 250 V / 440 V Min. switching voltage 10 V AgNi, 10 V AgNi/Au 0,2 m, 5 V AgNi/Au 5 m Rated load (capacity) AC1 10 A / 250 V AC 10 A / 277 V AC UL 508 AC15 3 A / 120 V 1,5 A / 240 V (B300) AC3 370 W (single-phase motor 0,5 HP / 240 V AC UL 508) DC1 10 A / 24 V DC (see Fig. 3) DC13 0,22 A / 120 V 0,1 A / 250 V (R300) Min. switching current 5 mA Max. inrush current 20 A Rated current 10 A Max. breaking capacity AC1 2 500 VA Min. breaking capacity 0,3 W AgNi, 0,3 W AgNi/Au 0,2 m, 0,05 W AgNi/Au 5 m Contact resistance 100 m Max. operating frequency at rated load AC1 1 200 cycles/hour no load 12 000 cycles/hour Coil data Rated voltage 50/60 Hz AC 6 ... 240 V DC 6 ... 220 V Must release voltage AC: 0,15 Un DC: 0,1 Un Operating range of supply voltage see Tables 1, 2 Rated power consumption AC 2,8 VA 50 Hz 2,5 VA 60 Hz DC 1,5 W Insulation according to PN-EN 60664-1 Insulation rated voltage 250 V AC Rated surge voltage 2 500 V 1,2 / 50 s Overvoltage category III Insulation pollution degree 3 Dielectric strength between coil and contacts 2 500 V AC type of insulation: basic contact clearance 1 500 V AC type of clearance: micro-disconnection pole - pole 2 000 V AC type of insulation: basic Contact - coil distance clearance 3 mm creepage 4,2 mm General data Operating / release time (typical values) AC: 12 ms / 10 ms DC: 18 ms / 7 ms Electrical life 5 resistive AC1 > 2 x 10 10 A, 250 V AC cos see Fig. 2 7 Mechanical life (cycles) > 2 x 10 Dimensions (L x W x H) 35 x 35 x 54,4 mm Weight 83 g o Ambient temperature storage -40...+85 C o o operating AC: -40...+55 C DC: -40...+70 C Cover protection category IP 40 PN-EN 60529 Environmental protection RTI PN-EN 116000-3 Shock resistance 10 g Vibration resistance 5 g 10...150 Hz o Solder bath temperature max. 270 C Soldering time max. 5 s The data in bold type pertain to the standard versions of the relays. 1 www.relpol.com.pl Export Sales Department phone +48 68 47 90 832, 951 e-mail: export relpol.com.pl 14.07.2014R15 - 2 CO, 3 CO industrial relays of small dimensions Coil data - DC voltage version Table 1 Coil resistance Coil operating range Rated voltage Acceptable Coil code at 20 C V DC V DC resistance min. (at 20 C) max. (at 55 C) 1006 6 28 10% 4,8 6,6 1012 12 110 10% 9,6 13,2 1024 24 430 10% 19,2 26,4 1048 48 1 750 10% 38,4 52,8 1060 60 2 700 10% 48,0 66,0 1110 110 9 200 10% 88,0 121,0 1120 120 11 000 10% 96,0 132,0 1220 220 37 000 10% 176,0 242,0 The data in bold type pertain to the standard versions of the relays. Coil data - AC 50/60 Hz voltage version Table 2 Coil resistance Coil operating range Rated voltage Acceptable Coil code at 20 C V AC V AC resistance min. (at 20 C) max. (at 55 C) 5006 6 4,3 15% 4,8 6,6 5012 12 18,5 15% 9,6 13,2 5024 24 75 15% 19,2 26,4 5048 48 305 15% 38,4 52,8 5060 60 475 15% 48,0 66,0 5115 115 1 840 15% 92,0 126,5 5120 120 1 910 15% 96,0 132,0 5220 220 6 980 15% 176,0 242,0 5230 230 7 080 15% 184,0 253,0 5240 240 7 760 15% 192,0 264,0 The data in bold type pertain to the standard versions of the relays. 2 CO 2 CO 3 CO 3 CO Test buttons R15-M404 and plugs R15-M203 need to ordered saparately. They substitute buttons type T. To exchange by Customer themselves. Information on test buttons (no latching) and plugs - page 6. 2 www.relpol.com.pl Export Sales Department phone +48 68 47 90 832, 951 e-mail: export relpol.com.pl 14.07.2014