R2M miniature industrial relays Relays of general application For plug-in sockets: 35 mm rail mount acc. to PN-EN 60715 on panel mounting For PCB and for soldering connections AC and DC coils Recognitions, certifications, directives: RoHS, Contact data Number and type of contacts 2 CO Contact material AgNi, AgNi/Au 0,2 m, AgSnO2 Rated / max. switching voltage AC 250 V / 250 V Min. switching voltage 5 V AgNi, 5 V AgNi/Au 0,2 m, 10 V AgSnO2 Rated load AC1 5 A / 250 V AC DC1 5 A / 24 V DC Min. switching current 5 mA AgNi, 5 mA AgNi/Au 0,2 m, 10 mA AgSnO2 Rated current 5 A Max. breaking capacity AC1 1 250 VA Min. breaking capacity 0,3 W AgNi, 0,3 W AgNi/Au 0,2 m, 1 W AgSnO2 Contact resistance 100 m Max. operating frequency at rated load AC1 1 200 cycles/hour no load 36 000 cycles/hour Coil data Rated voltage 50/60 Hz AC 6 ... 240 V DC 6 ... 110 V Must release voltage 0,05 Un Operating range of supply voltage see Tables 1, 2 Rated power consumption AC 1,2 VA DC 0,9 W Insulation according to PN-EN 60664-1 Insulation rated voltage 250 V AC Rated surge voltage 2 500 V 1,2 / 50 s Overvoltage category II Insulation pollution degree 3 Dielectric strength between coil and contacts 2 000 V AC type of insulation: basic contact clearance 1 000 V AC type of clearance: micro-disconnection pole - pole 2 000 V AC type of insulation: basic Contact - coil distance clearance 3 mm creepage 4 mm General data Operating / release time (typical values) AC: 8 ms / 7 ms DC: 10 ms / 3 ms Electrical life 5 resistive AC1 > 2 x 10 5 A, 250 V AC cos see Fig. 2 7 Mechanical life (cycles) > 10 Dimensions (L x W x H) 27,5 x 14 x 32,9 mm Weight 22 g o Ambient temperature storage -40...+70 C o operating -40...+55 C Cover protection category IP 40 PN-EN 60529 Shock resistance 10 g Vibration resistance 5 g 10...150 Hz o Solder bath temperature max. 270 C Soldering time max. 5 s The data in bold type pertain to the standard versions of the relays. Note: relays with AgNi contacts can be used up to 5 A at resistive and inductive load. 1 www.relpol.com.pl Export Sales Department phone +48 68 47 90 832, 951 e-mail: export relpol.com.pl 14.07.2014R2M miniature industrial relays Coil data - DC voltage version Table 1 Coil resistance Coil operating range Rated voltage Acceptable Coil code at 20 C V DC V DC resistance min. (at 20 C) max. (at 55 C) 1006 6 47 10% 4,8 6,6 1012 12 188 10% 9,6 13,2 1024 24 750 10% 19,2 26,4 1048 48 2 660 10% 38,4 52,8 1060 60 4 000 10% 48,0 66,0 1080 80 7 100 10% 64,0 88,0 1110 110 13 480 10% 88,0 121,0 The data in bold type pertain to the standard versions of the relays. Coil data - AC 50/60 Hz voltage version Table 2 Coil resistance Coil operating range Rated voltage Acceptable Coil code at 20 C V AC V AC resistance min. (at 20 C) max. (at 55 C) 5006 6 16 10% 4,8 6,6 5012 12 68 10% 9,6 13,2 5024 24 270 10% 19,2 26,4 5050 50 1 150 10% 40,0 55,0 5100 100 5 590 10% 80,0 110,0 5110 110 5 670 10% 88,0 121,0 5115 115 5 990 10% 92,0 126,0 5120 120 6 390 10% 96,0 132,0 5220 220 21 470 10% 176,0 242,0 5230 230 21 470 10% 184,0 253,0 5240 240 25 390 10% 192,0 264,0 The data in bold type pertain to the standard versions of the relays. 2 www.relpol.com.pl Export Sales Department phone +48 68 47 90 832, 951 e-mail: export relpol.com.pl 14.07.2014