RM87, RM87 sensitive miniature relays RM87N sensitive RM87N-...-01 Cadmium - free contacts Height 15,7 mm 5000 V / 10 mm reinforced insulation For PCB and plug-in sockets Accessories: sockets and modules AC and DC coils - standard (RM87), DC coils - sensitive (RM87 sensitive) Available special versions: with transparent cover with the increased dielectric strength of the contact clearance Compliance with standard PN-EN 60335-1 Recognitions, certifi cations, directives: RoHS, Contact data RM87 - standard version RM87 sensitive - sensitive version Number and type of contacts 1 CO, 1 NO 1 NO Contact material AgNi, AgNi/Au 5 m, AgSnO2 Rated / max. switching voltage AC 250 V / 440 V Min. switching voltage 5 V AgNi, 5 V AgNi/Au 5 m, 10 V AgSnO2 Rated load (capacity) AC1 12 A / 250 V AC 10 A / 250 V AC AC15 3 A / 120 V 1,5 A / 240 V (B300) AC3 750 W (single-phase motor) DC1 12 A / 24 V DC (see Fig. 3) 10 A / 24 V DC (see Fig. 4) DC13 0,22 A / 120 V 0,1 A / 250 V (R300) Min. switching current 5 mA AgNi, 2 mA AgNi/Au 5 m, 10 mA AgSnO2 Max. inrush current 25 A AgSnO2 20 A AgSnO2 Rated current 12 A 10 A Max. breaking capacity AC1 3 000 VA 2 500 VA Min. breaking capacity 0,3 W AgNi, 0,05 W AgNi/Au 5 m, 1 W AgSnO2 Contact resistance 100 m Max. operating frequency at rated load AC1 600 cycles/hour no load 72 000 cycles/hour Coil data Rated voltage 50/60 Hz AC 12 ... 240 V DC 3 ... 110 V 5 ... 48 V Must release voltage AC: 0,15 Un DC: 0,1 Un Operating range of supply voltage see Tables 1, 3 and Fig. 5, 7 see Table 2 and Fig. 6 Rated power consumption AC 0,75 VA DC 0,4 ... 0,48 W 0,25 W Insulation according to PN-EN 60664-1 Insulation rated voltage 400 V AC Rated surge voltage 4 000 V 1,2 / 50 s Overvoltage category III Insulation pollution degree 3 Dielectric strength between coil and contacts 5 000 V AC type of insulation: reinforced contact clearance 1 000 V AC type of clearance: micro-disconnection 2 000 V AC contact 1 NO, type of clearance: full-disconnection Contact - coil distance clearance 10 mm creepage 10 mm General data Operating / release time (typical values) 7 ms / 3 ms Electrical life (number of cycles) 5 5 resistive AC1 > 10 12 A, 250 V AC > 1,7 x 10 10 A, 250 V AC cos see Fig. 2 5 DC L/R=40 ms > 10 0,15 A, 220 V DC 7 Mechanical life (cycles) > 3 x 10 Dimensions (L x W x H) / Weight 29 x 12,7 x 15,7 mm / 14 g o Ambient temperature storage -40...+85 C o o o operating AC: -40...+70 C DC: -40...+85 C -40...+70 C Cover protection category IP 40 or IP 67 PN-EN 60529 Environmental protection RTII or RTIII PN-EN 116000-3 Shock resistance 30 g Vibration resistance 10 g 10...150 Hz o Solder bath temperature / Soldering time max. 270 C / max. 5 s The data in bold type pertain to the standard versions of the relays. For special version (only for RM87 - standard version) - relays in transparent cover: only available with IP 40 and RTII, operating temperature -40...+70 C - see Ordering codes For special version with contact 1 NO (only for RM87 - standard version): relays with increased contact gap, 1 dielectric strength 2000 V AC - see Ordering codes www.relpol.com.pl Export Sales Department phone +48 68 47 90 832, 951 e-mail: export relpol.com.pl 14.07.2014RM87, RM87 sensitive miniature relays Coil data - DC voltage version, RM87 - standard version Table 1 Coil resistance Coil operating range Rated voltage Acceptable Coil code at 20 C V DC V DC resistance min. (at 20 C) max. (at 20 C) 1003 3 22 10% 2,1 7,6 1005 5 60 10% 3,5 12,7 1006 6 90 10% 4,2 15,3 1009 9 200 10% 6,3 22,9 1012 12 360 10% 8,4 30,6 1018 18 710 10% 12,6 45,9 1024 24 1 440 10% 16,8 61,2 1036 36 3 140 10% 25,2 91,8 1048 48 5 700 10% 33,6 122,4 1060 60 7 500 10% 42,0 153,0 1110 110 25 200 10% 77,0 280,0 The data in bold type pertain to the standard versions of the relays. Coil data - DC voltage version, RM87 sensitive - sensitive version Table 2 Coil resistance Coil operating range Rated voltage Acceptable Coil code at 20 C V DC V DC resistance min. (at 20 C) max. (at 20 C) S005 5 102 10% 3,75 15,0 S006 6 144 10% 4,50 18,0 S009 9 330 10% 6,75 27,0 S010 10 400 10% 7,50 30,0 S012 12 580 10% 9,00 36,0 S018 18 1 300 10% 13,50 54,0 S024 24 2 300 10% 18,00 72,0 S048 48 9 340 10% 36,00 144,0 Coil data - AC 50/60 Hz voltage version, RM87 - standard version Table 3 Coil resistance Coil operating range Rated voltage Acceptable Coil code at 20 C V AC 50 Hz V AC resistance min. (at 20 C) max. (at 20 C) 5012 12 100 10% 9,6 13,2 5024 24 400 10% 19,2 28,8 5048 48 1 550 10% 38,4 57,6 5060 60 2 600 10% 48,0 72,0 5110 110 8 900 10% 88,0 132,0 5115 115 9 600 10% 92,0 138,0 5120 120 10 200 10% 96,0 144,0 5220 220 35 500 10% 176,0 264,0 5230 230 38 500 10% 184,0 276,0 5240 240 42 500 15% 192,0 288,0 The data in bold type pertain to the standard versions of the relays. 2 www.relpol.com.pl Export Sales Department phone +48 68 47 90 832, 951 e-mail: export relpol.com.pl 14.07.2014