BBoootot LE LEDDss PoPowweerr L LEDED UserUser L LEEDsDs E1E1 H Heeaadderer 2. Connection ReRenneessaass SSttaarrtterer Ki Kitt 9. Fit the LCD module to the connector marked LCD on the RSK. Ensure all the pins of the connector are QuQuiicckk S Sttarartt foforr R RXX6622TT correctly inserted in the socket. 10. Connect the E1 debugger module to the connector marked E1 on the RSK using the ribbon cable. SeSerriiaall Po Portrt AApplicationpplication I Innteterrffacesaces ResetReset S Swwitcitchh DC PDC Poowweer r JJaackck 11. Connect the E1 debugger module to a spare USB port of your PC. The green ACT LED on the E1 debugger will flash. 12. The Found New Hardware Wizard will appear. Please follow the steps below to install the drivers. Note that, administrator privileges are required for a Windows XP/Vista/7 machine. LCD MLCD Moduodulele Windows XP Windows Vista / Windows 7 a. Select option No, not this time in Found New a. Device driver software installed successfully LCLCDD M Moodudullee HeaHeadederr Hardware Wizard dialog, and click <Next> pop-up will appear in the Windows toolbar and LILINN button. installation will complete. b. Verify the Recommended option is selected and click <Next>. c. Click <Finish> to close the wizard. CANCAN AAnnaallogogue Aue Addjujusstt E1E1 Em Emuullaattoorr Note: The Windows driver signing dialog may be displayed. Please accept the driver to continue. AAppppliclicaattioion Inn Inteterfrfacesaces UUsserer S Swiwittcchheses 13. The green ACT LED on the E1 debugger will illuminate. 3. HEW Workspace HEW integrates various tools such as compiler, assembler, debugger and editor into a common graphical user interface. To learn more on how to use HEW, open the HEW manual installed on your computer (Start Menu > All Programs > Renesas > High-performance Embedded Workshop > Manual Navigator) 14. Launch HEW from the Start Menu. (Start Menu > All Programs > Renesas > High-performance Embedded Workshop). 15. In the Welcome dialog box: Verify Create New Workspace is selected. Click <OK> 1. Installation 16. In the New Project Workspace dialog box: Set the CPU Family to RX, and verify the Tool chain is set to Do not connect the E1 debugger module until the software support has been installed. Renesas RX Standard. Select RSKRX62T from the left hand pane. 1. Insert the CD into your computers CD-ROM drive. The CD should automatically run the installation program. 17. Enter a name for the workspace. The project name will be automatically completed with the Workspace If the installer does not start, browse to the CD root folder and double click on setup.exe. name. You can change this name to Tutorial if required. Click <OK>. 2. Windows Vista/7 users may see User Account Control dialog box. If applicable, enter the administrator 18. On the RSKRX62T Step 1 window: Select Tutorial and click <Next>. password and click <OK>. 19. On the RSKRX62T Step 2 window: Click <Finish>. 3. The installer will ask you which language is to be used, please choose the appropriate one and click <OK>. 20. On the Project Generator Information window: Click <OK>. 4. On the first screen of the installer, click <Next>. The project that is created has two configurations. The Release configuration compiles the project without 5. The License Agreement will be shown, read and click <Yes>. any debugger support and can be used for the final release code version. The Debug configuration can be 6. The next screen asks you to pick the world region please select your region and click <Next>. used to debug the user application. 7. The destination folders are shown on the next screen. It is recommended to accept the default settings. Click <Next> to begin copying the program files into the destination folders. 21. Select the Debug build configuration in the left hand drop down list on the toolbar. Note: The Windows driver signing dialog may be displayed. Please accept the driver to continue. 22. Click on the Build icon to compile, assemble and link the project. 8. After the completion of successful installation, click <Finish>. 35. The flash memory write program is then downloaded to the microcontroller. The Output window in HEW will 4. Programming and Debug state Connected. 23. Ensure that SessionRX600 E1 E20 SYSTEM session in the right hand drop down list on the tool bar 36. Right click on the download module listed in the left hand is selected. pane and select Download. The code will be downloaded 24. Click the <Connect> button on the Debug toolbar. to the microcontroller. 25. Select the correct MCU Group type (RX62T Group as illustrated). 26. Select the correct device type (R5F562TA as illustrated). 37. Click the <Reset Go> button. 27. Select Debugging Mode. You will see the LEDs flash on the board. Pressing any of 28. Select Power target from emulator with 5.0V as the power supply and click <OK>. the switches on the RSK will allow you to control the rate 29. In the next dialog box Configuration Properties ensure that Single-chip mode is set. of flashing using the Analog Adjust control. 30. Click <OK>. 38. Click the <Stop> button. The code will stop and the source code will be opened at the current program counter. 5. Next Step After you have completed this quick start procedure, please review the tutorial code and sample code that came with the kit. You can add projects to the current workspace by selecting (Project > Insert Project) from the main menu. The tutorials will help you understand the device and development process using Renesas Development Tools. The Hardware manual supplied with this RSK is current at the time of publication. Please check for any updates to the device manual from the Renesas internet site at: www.renesas.com/rskrx62t 6. Renesas RX Compiler The version of the compiler provided with this RSK is fully functional but time limited. You have 60 days to evaluate the full product before the compiler will limit the code linker to 128k bytes. Full licensed RX compiler versions are available from your Renesas supplier. 7. Support Online technical support and information is available at: www.renesas.com/rskrx62t Technical Contact Details America: techsupport.america renesas.com Europe: tools.support.eu renesas.com Japan: csc renesas.com First use of the E1 module 31. The Please choose driver dialog will be shown. Click <OK>. Note on Autoupdate: The Autoupdater is configured to automatically add itself to the Startup folder in 32. The Driver Details dialog will be shown, please select the Windows Start Menu and use the registry defaults for access to the web. After restarting the machine Renesas E-Series USB Driver as illustrated. The Interface and Channel items will be automatically populated. Click the Icon will appear in the System Tray next to the clock. To change the settings or access Autoupdate, simply right-click on the icon and use the menu that appears. <Close>. 33. The Firmware setup dialog will be shown warning you not to disconnect the USB cable until the firmware download is 2010 (2011) Renesas Electronics Europe Limited. All rights reserved. complete. Click <OK>. 2010 (2011) Renesas Electronics Corporation. All rights reserved. 34. The firmware will be downloaded to the E1 module this will take a few moments. 2010 (2011) Renesas Solutions Corp. All rights reserved. Website: www.renesas.com Please do not disconnect the E1 from the host during download, doing so is likely to damage the E1 module. D009744 11 S01 V0201