SF2205E 879 MHz Surface-mount 3.0 x 3.0 x 1.3 mm Package Complies with Directive 2002/95/EC (RoHS) SAW Filter Pb Absolute Maximum Ratings Rating Value Units Input Power Level 10 dBm DC Voltage on any Non-ground Terminal 3 V Operable Temperature Range -45 to +125 C Specification Temperature Range -25 to +75 C Storage Temperature Range in Tape and Reel -40 to +85 C SM3030-6 C Solder Reflow Temperature, 10 seconds, 5 cycles maximum 260 Electrical Characteristics Characteristic Sym Notes Min Typ Max Units F Center Frequency 879 MHz C Maximum Insertion Loss, 864 to 894 MHz IL 3.5 dB dB Amplitude Ripple, 864 to 894 MHz 2.0 P-P I/O Return Loss, 864 to 894 MHz 10 dB Attenuation Referenced to 0 dB: 10 to 840 MHz 40 920 to 1000 MHz 30 dB 1000 to 2600 MHz 25 Z Source Impedance 50 S Z Load Impedance 50 L Case Style SM3030-6 3.0 x 3.0 mm Nominal Footprint Lid Symbolization (Y=year, WW=week, S=shift) dot=pin 1 indicator 937, YWWS Standard Reel Quantity Reel Size 7 Inch 500 Pieces/Reel Reel Size 13 Inch 3000 Pieces/Reel Electrical Connections Connection Terminals Input 5 Output 2 Ground All Others CAUTION: Electrostatic Sensitive Device. Observe precautions for handling. NOTES: 1. Unless noted otherwise, all specifications apply over the operating temperature range with filter soldered to the specified demonstration board with impedance matching to 50 and measured with 50 network analyzer. 2. Unless noted otherwise, all frequency specifications are referenced to the nominal center frequency, fc. 3. Rejection is measured as attenuation below the minimum IL point in the passband. Rejection in final user application is dependent on PCB layout and external impedance matching design. See Application Note No. 42 for details. 4.LRI or after the part number indicateslow rate initial productio andEN or indicatesengineering prototypes 5. The design, manufacturing process, and specifications of this filter are subject to change. 6. Either Port 1 or Port 2 may be used for either input or output in the design. However, impedances and impedance matching may vary between Port 1 and Port 2, so that the filter must always be installed in one direction per the circuit design. 7. US and international patents may apply. 8. Murata, stylized Murata logo, and Murata N.A., Inc. are registered trademarks of Murata Manufacturing Co., Ltd. Copyright Murata Manufacturing Co., Ltd. All rights reserved. February 2013 SF2205E (R) 3/3/17 Page 1 of 5 www.murata.comFilter Broadband Response, 10 to 3000 MHz Filter Test Circuit SF2205E Copyright Murata Manufacturing Co., Ltd. All rights reserved. February 2013 www.murata.com SF2205E (R) 3/3/17 Page 2 of 5