Digit al Multimet er HMC8012 HMC8012 - rear view of GPIB-version R 5 3/4-Digit Display (480,000 Counts) R Simultaneous Display of 3 Measurements, e.g. DC + AC + Statistics R Up to 200 Measurements per Second R DC Basic Accuracy 0,015% R 12 Measurement Functions: DCV, DCI, True RMS, ACV and ACI, HZC95 Frequency, 2- and 4-Wire Resistance, Capacitance, Continuity, 19 rackmount kit 2RU Diode Test, Temperature, Power R Crisp color TFT display for excellent readability R Resolution: 1V, 100 nA, 1m, 1pF, 1Hz, 0,1 C R True RMS Measurement AC, AC + DC R Mathematic Functions: Limit Testing, Minimum/Maximum, Average, Offset, DC Power, dB, dBm HZ15 (included) Silicon test lead with safety R Temperature Measurements with Platinum Sensors connector and probe (PT100/PT500/PT1000) R Data Logging in .CSV-Format to Internal Memory or USB-Stick R Interfaces: USB-TMC and Ethernet / LXI, optional IEEE-488 (GPIB) R SCPI commands widely compatible with Agilent 34410A HMC8012Digital Multimeter HMC8012 All data valid at 23C 5K after 90 minutes warm-up and with 5 3/4 digits. DC Specifications DC Accuracy in (% of reading + % of range): 1) Function Range Test Current Input Impedance 1 Year 23 C 5 K Temp. Coefficient Voltage drop 0-18 C, 28-55 C DC Voltage 400,000 mV 10 M/>10 G 0,015+0,002 0,0010+0,0005 4,00000 V 10 M/>10 G 0,015+0,002 0,0008+0,0003 40,0000 V 10 M 0,020+0,002 0,0010+0,0005 400,000 V 10 M 0,020+0,002 0,0015+0,0005 1000,00 V 10 M 0,025+0,002 0,0015+0,0005 Resistance 400,000 1 mA 0,050+0,005 0,0020+0,0005 2) (2/4-wire) 4,00000 k 1 mA 0,015+0,002 0,0020+0,0002 40,0000 k 100 A 0,015+0,002 0,0020+0,0002 400,000 k 10 A 0,030+0,003 0,0020+0,0002 4,00000 M 1 A 0,060+0,005 0,0020+0,0002 40,0000 M 100 nA 0,250+0,003 0,0080+0,0005 250,000 M 460 nA 10 M (parallel) 2,000+0,010 0,200+0,0005 4) DC Current 20,0000 mA <0,30 V 0,05+0,010 0,008+0,0010 200,000 mA <0,27 V 0,05+0,010 0,008+0,0010 2,00000 A <0,2 V 0,25+0,070 0,012+0,0015 3) 10,0000 A <0,60 V 0,25+0,070 0,010+0,0010 Continuity 4000 1 mA 0,05+0,010 0,005+0,0005 Diode Test 5 V 1 mA 0,05+0,010 0,005+0,0005 Notes: 1) 240.000 / 480.000 counts exept in 1000 V and 10 A range 2) Specifications are for 4-wire measurement 2-wire measurement using NULL function. 3) Maximum current load at >5 A is 30 seconds, followed by a pause of >30 seconds 4) At 250 V maximum AC Specifications AC Accuracy in (% of reading + % of range): 1) Function Range Frequency 1 Year 23 C 5 K Temp. Coefficient 0-18 C, 28-55 C 2) AC Voltage 400,000 mV 10 Hz20 Hz 3,0+0,05 0,01+0,01 4,00000 V 20 Hz45 Hz 1,5+0,05 0,01+0,01 40,0000 V 45 Hz20 kHz 0,3+0,05 0,01+0,01 400,000 V 20 kHz50 kHz 1,0+0,05 0,02+0,01 6) 750,00 V 50 kHz100 kHz 3,0+0,05 0,05+0,01 5) AC Current 20,0000 mA 20 Hz40 Hz 1,5+0,05 0,01+0,01 200,000 mA 40 Hz1 kHz 0,5+0,05 0,01+0,01 2,00000 A 1 kHz5 kHz 1,5+0,05 0,01+0,01 4) 3) 10,0000 A 5 kHz10 kHz 2,5+0,05 0,01+0,01 Notes: 1) 240.000 / 480.000 counts exept in 750 V and 10 A range 2) Specifications are for sinusoidal curves. Input impedance is 1 M parallel <100 pF 3) Except 10 A range 4) Maximum current load at >5 A is 30 seconds, followed by a pause of >30 seconds 5) At 250 V maximum 6) For ACV measurements and frequencies above 50 kHz the user is required to choose an appropriate measurement range. Frequency Counter Specifications Frequency Accuracy in (% of reading): 1) Function Range Frequency 1 Year 23 C 5 K Temp. Coefficient 0-18 C, 28-55 C 2) AC Voltage all ranges 5 Hz700 kHz 0,01 0,005 2) AC Current 20 mA, 200 mA 5 Hz10 kHz 0,01 0,005 2 A, 10 A 5 Hz5 kHz 0,01 0,005 Notes: 1) Display of frequency available as 2nd measurent for main functions ACV and ACI 2) Input sensitivity: >7,5 % of full scale (5 Hz-400 kHz) resp. >20 % (400-700 kHz) Frequency Counter Resolution Setting Measurement time Display range Resolution Slow 1 s 999,999 kHz 1 Hz Medium 100 ms 999,99 kHz 10 Hz Fast 10 ms 999,9 kHz 100 Hz