25kHz LCR-Meter HM8018 Option HZ19 SMD Test Tweezers R Measurement Functions: L, C, R, , Q/D, Z R Basic Accuracy 0.2 % R 5 Measurement Frequencies: 100 Hz, 120 Hz, 1 kHz, 10 kHz, 25 kHz R Max. Resolution: 0.001 , 0.001 pF, 0.01 H Option HZ18 Kelvin Test R 2- and 4-Wire Measurement, parallel and serial Mode Lead Mainframe HM8001-2 required for Operation HM8018Display 5-digits 7-Segment LEDs with sign 25 kHz-LCR-Meter HM8018 Display Parameters: All data valid at 23C after 30 minutes warm-up. Value Calculation from measurement value and % Value reference value stored Deviation Measurement functions % Offset Measuring modes: R, L, C, , Q/D, Z Equivalent circuits: serial, parallel Miscellaneous Measuring method: 2-wire, 4-wire The inputs are short-circuit-proof and overvoltage protected up to 100 V dc Measuring ranges: R: 0.001 99.9 M with a maximum energy consumption of 1 J. C: 0.001 pF99.9 mF One configuration can be saved. L: 0.01 H9,999 H Power supply +5 V/300 mA Q: 0.000199.9 (from mainframe): +5.2 V/50 mA D: 0.00019.9999 -5.2 V/50 mA : (-180.00)(+180.00) ( = 2 W) 0.2 % +5+40 C Basic accuracy: Operating temperature: 100 Hz, 120 Hz, 1 kHz, 10 kHz, 25 kHz -20+70 C Measuring frequencies: Storage temperature: Freq. Accuracy: 100 ppm (except 120 Hz: 120.2 Hz 100 ppm) Rel. humidity: 580 % (non condensing) Measuring voltage: 0.5 V 10 % (unloaded) Dimensions (W x H x D) rms Measuring rate: 2 measurements/second (without 22-pole flat plug): 135 x 68 x 228 mm Range changing: automatic, manual Weight: approx. 0.5 kg DC Bias voltage: 1 V 10 % Zero setting: Open/short circuit compensation Compensation limits: Short: R <10 Z <15 Included in delivery: Operating manual, CD Open: Z >10 k Recommended accessories: HZ10S 5 x silicone test lead (measurement connection in black) HZ10R 5 x silicone test lead (measurement connection in red) Measurement accuracy HZ10B 5 x silicone test lead (measurement connection in blue) with D <0.1 or Q >10 C: A = A x A (1 + C /C + C /C) e f d x max min x HZ17 Kelvin test lead (4-wire) with probe tips L: A = A x A (1 + L /L + L /L) e f d x max min x HZ18 Kelvin test lead (4-wire) with gold plated contacts Z: A = A (1 + Z /Z + Z /Z) e f x max min x HZ19 Kelvin test lead (4-wire) with SMD-Test-tweezers R: A = A x A (1 + R /R + R /R) e f d x max min x A = 1 for D <0.1 d 2 with D 0.1 A = d Z1X + D with the parameters C , L , Z , R = Measurement value x x x x A = 0.2 % at f = 100 Hz, 120 Hz, 1 kHz f A = 0.3 % at f = 10 kHz f A = 0.5 % at f = 25 kHz f Parameter Auto Range C 160 F/f (f in kHz) max C 53 pF/f (f in kHz) min L 480 H/f (f in kHz) max L 0.16 mH/f (f in kHz) min Z , R 3 M max max Z , R 0.5 min min Dissipation factor accuracy: Quality factor accuracy: Phase angle accuracy: HM8018E/100812 C&E Subject to change without notice HAMEG Instruments GmbH DQS-certified in accordance with DIN EN ISO 9001:2008, Reg.-No.: 071040 QM08 HAMEG Instruments GmbH Industriestr. 6 D-63533 Mainhausen Tel +49 (0) 6182 8000 Fax +49 (0) 6182 800100 www.hameg.com info hameg.com