DATASHEET Single-Stage Filters FN 2030
General Purpose AC/DC EMI Filter with High Attenuation Performance
Rated currents from 1 to 30 A Approvals
High performance filter attenuation
High differential-mode attenuation
Optional medical versions (B type)
Optional safety versions (A type)
Optional enhanced performance versions
Optional overvoltage protection (Z type)
Features and benefits
FN 2030 filters are designed for easy and fast chassis
mounting
Performance indicators The FN 2030 filters are also available as B versions
with no Y-capacitors for medical applications as well
as A versions with low capacitance for safety critical
applications with a requirement for low leakage
currents
FN 2030 filters offer an optimized filter range for
high performance AC and DC applications , in same
compact size (M, N1 types)
All filters provide an exceptional conducted
attenuation performance, based on chokes with
high permeable core material and excellent thermal
behavior
The higher inductivity versus amperage offers
Technical specifications increased attenuation performance with same form
factor compared to FN 2010 and FN 2020 filter series
All FN 2030 filters can be delivered with optional
Rated voltage* 250 VAC, 50/60 Hz; 250 VDC
surge pulse protection (Z type).
Operating frequency dc to 400 Hz
Various terminal options allow you to select the
Rated currents 1 to 30 A @ 40C max.
desired connection style
P > PE 2000 VAC for 2 sec (equiv. cap <88 nF)
High potential test voltage
P > PE 2550 VDC for 2 sec (equiv. cap >88 nF)
P > PE 2500 VAC for 2 sec (B types)
Typical application
P > N 1100 VDC for 2 sec
Temperature range (operation and storage) -25C to +100C (25/100/21)
Electrical and electronic equipment
Certified to UL 1283, CSA 22.2 No. 8 1986, IEC/EN 60939 (applies to
Consumer goods
AC and DC applications)
Household equipment
Flammability corresponding to UL 94 V-2 or better
Medical equipment
Surge pulse protection (Z type) 2 kV (P-N), IEC 61000-4-5
Electronic data processing equipment
MTBF @ 40C/230 V (Mil-HB-217F) 2,200,000 hours (1 to 10 A types)
1,200,000 hours (12 to 30 A types)
Office automation and datacom equipment
Various noisy applications requiring high filter
*maximum RMS operating voltage at rated frequency or the maximum DC operating voltage
performance
Typical electrical schematic2 EMC/EMI Products Schaffner Group Datasheets 2017
Filter selection table
Filter* Rated current Leakage current** Inductance Capacitance Resistance Input/Output Weight
@ 40C (25C) @ 250 VAC/50 Hz L Cx Cy R connections
(@ 120 VAC/60 Hz)
[A] [mA] [mH] [F] [nF] [k] [g]
FN 2030-1-.. 1 (1.1) 0.31 (0.18) 20 0.22 2.2 1000 -06 -07 58
FN 2030-3-.. 3 (3.4) 0.47 (0.27) 14 0.33 3.3 1000 -06 -07 87
FN 2030-4-.. 4 (4.5) 0.47 (0.27) 14 0.33 3.3 1000 -06 -07 92
FN 2030-6-.. 6 (6.7) 0.66 (0.38) 8 0.47 4.7 680 -06 -07 100
FN 2030-8-.. 8 (8.9) 0.66 (0.38) 8 0.47 4.7 680 -06 -07 170
FN 2030-10-.. 10 (11.2) 0.66 (0.38) 8 0.47 4.7 680 -06 -07 196
FN 2030-12-.. 12 (13.4) 0.79 (0.45) 4 1.0 10 330 -06 -07 185
FN 2030-16-.. 16 (17.9) 0.79 (0.45) 4 1.0 10 330 -06 -07 225
FN 2030-20-.. 20 (22.4) 0.79 (0.45) 4 1.0 10 330 -06 -08 285
FN 2030-30-08 30 (33.5) 0.79 (0.45) 2 1.0 10 330 -08 326
FN 2030 A-1-.. 1 (1.1) 0.07 (0.04) 20 0.22 0.47 1000 -06 -07 58
FN 2030 A-3-.. 3 (3.4) 0.07 (0.04) 14 0.33 0.47 1000 -06 -07 87
FN 2030 A-4-.. 4 (4.5) 0.07 (0.04) 14 0.33 0.47 1000 -06 -07 92
FN 2030 A-6-.. 6 (6.7) 0.07 (0.04) 8 0.47 0.47 680 -06 -07 100
FN 2030 A-8-.. 8 (8.9) 0.07 (0.04) 8 0.47 0.47 680 -06 -07 170
FN 2030 A-10-.. 10 (11.2) 0.07 (0.04) 8 0.47 0.47 680 -06 -07 196
FN 2030 A-12-.. 12 (13.4) 0.07 (0.04) 4 1.0 0.47 330 -06 -07 185
FN 2030 A-16-.. 16 (17.9) 0.07 (0.04) 4 1.0 0.47 330 -06 -07 225
FN 2030 A-20-.. 20 (22.4) 0.07 (0.04) 4 1.0 0.47 330 -06 -08 285
FN 2030 A-30-08 30 (33.5) 0.07 (0.04) 2 1.0 0.47 330 -08 326
FN 2030 B-1-.. 1 (1.1) 0.00 20 0.22 1000 -06 -07 58
FN 2030 B-3-.. 3 (3.4) 0.00 14 0.33 1000 -06 -07 87
FN 2030 B-4-.. 4 (4.5) 0.00 14 0.33 1000 -06 -07 92
FN 2030 B-6-.. 6 (6.7) 0.00 8 0.47 680 -06 -07 100
FN 2030 B-8-.. 8 (8.9) 0.00 8 0.47 680 -06 -07 170
FN 2030 B-10-.. 10 (11.2) 0.00 8.45 0.47 680 -06 -07 196
FN 2030 B-12-.. 12 (13.4) 0.00 4 1.0 330 -06 -07 185
FN 2030 B-16-.. 16 (17.9) 0.00 4 1.0 330 -06 -07 225
FN 2030 B-20-.. 20 (22.4) 0.00 4 1.0 330 -06 -08 285
FN 2030 B-30-08 30 (33.5) 0.00 2 1.0 330 -08 326
Enhanced performance
FN 2030 N1-1-06 1 (1.1) 5.34 (3.08) 20 0.22 68 1000 -06 65
FN 2030 M-3-06 3 (3.4) 3.69 (2.28) 14 0.33 47 1000 -06 110
FN 2030 M-4-06 4 (4.5) 3.69 (2.28) 14 0.33 47 1000 -06 110
FN 2030 M-6-06 6 (6.7) 3.69 (2.28) 8 0.47 47 680 -06 120
FN 2030 N1-8-06 8 (8.9) 5.34 (3.08) 8 0.47 68 3680 -06 200
FN 2030 N1-10-06 10 (11.2) 5.34 (3.08) 8 0.47 68 680 -06 200
FN 2030 N1-12-06 12 (13.4) 5.34 (3.08) 4 1.0 68 330 -06 210
FN 2030 M-16-06 16 (17.9) 3.69 (2.28) 4 1.0 47 330 -06 265
FN 2030 M-20-.. 20 (22.4) 3.69 (2.28) 4 1.0 47 330 -06 -08 326
FN 2030 M-30-08 30 (33.5) 3.69 (2.28) 2 1.0 47 330 -08 346
* To compile a complete part number, please replace the -.. with the required I/O connection style. For surge pulse protection, please add Z (e.g. FN 2030Z-10-06, FN 2030BZ-20-08).
The different letters code the used Cy values in the filter type (A = 0.47nF; M = 47nF; N1 = 47nF)
** Maximum leakage under usual AC operating conditions (acc. IEC60939-3). Note: if the neutral line is interrupted, worst case leakage could reach twice this level. Leakage current
for DC application is 0 mA