DATASHEET Two-Stage Filters FN 2060 Multi-stage General Purpose EMI Filter Rated currents from 1 to 30 A Approvals High differential and common-mode attenuation Optional medical versions (B type) Optional safety versions (A type) Features and benefits FN 2060 two-stage filters are designed for easy and fast chassis mounting FN 2060 filters are also available as B versions Technical specifications without Y-capacitors for medical applications as well as A version with low capacitance for safety Operating voltage 110/250 VAC, 50/60 Hz critical applications with necessity for low leakage currents Operating frequency dc to 400 Hz Rated currents 1 to 30 A 40 C max. All filters provide a high conducted attenuation performance, based on chokes with high saturation High potential test voltage P > PE 2000 VAC for 2 sec resistance and excellent thermal behavior P > N 1100 VDC for 2 sec FN 2060 two-stage filters are designed for noisy P > PE 2500 VAC for 2 sec (B types) applications requiering good differential and Temperature range (operation and storage) -25 C to +100 C (25/100/21) common-mode attenuation Flammability corresponding to UL 94 V-2 or better FN 2060 filters are also available as single-stage Design corresponding to UL 1283, CSA 22.2 No. 8 1986, IEC/EN 60939 filters (FN 2010 series) MTBF 40C/230V (Mil-HB-217F) 950,000 hours Various terminal options allow you to select the 1,650,000 hours (B types) desired connection style Typical applications Electrical and electronic equipment Consumer goods Household equipment Building automation Industrial applications Machinery Medical equipment Electronic data processing equipment Office automation and datacom equipment Various noisy applications requiering good filter performance Typical electrical schematic 2 EMC/EMI Products Schaffner Group Datasheets 2015 Filter selection table Filter* Rated current Leakage current** Inductance Capacitance Resistance Input/Output Weight 40 C (25 C) 230 VAC/50 Hz L Cx Cy R connections A mA mH F nF k g FN 2060-1-.. 1 (1.2) 0.734 12 0.22 4.7 1000 -06 -07 120 FN 2060-3-.. 3 (3.5) 0.734 2.5 0.22 4.7 1000 -06 -07 120 FN 2060-6-.. 6 (6.9) 0.734 0.97 0.22 4.7 1000 -06 -07 120 FN 2060-10-.. 10 (11.5) 0.734 0.8 0.47 4.7 470 -06 -07 190 FN 2060-12-.. 12 (13.8) 0.734 0.58 0.47 4.7 470 -06 -07 190 FN 2060-16-.. 16 (18.4) 0.734 0.65 0.33 4.7 1000 -06 -07 -08 260 FN 2060-20-.. 20 (23) 0.734 0.6 1 4.7 220 -06 -08 480 FN 2060-30-08 30 (34.5) 0.867 0.6 1 10 220 -08 950 FN 2060A-1-.. 1 (1.2) 0.074 12 0.22 0.47 1000 -06 -07 120 FN 2060A-3-.. 3 (3.5) 0.074 2.5 0.22 0.47 1000 -06 -07 120 FN 2060A-6-.. 6 (6.9) 0.074 0.97 0.22 0.47 1000 -06 -07 120 FN 2060A-10-.. 10 (11.5) 0.074 0.8 0.47 0.47 470 -06 -07 190 FN 2060A-12-.. 12 (13.8) 0.074 0.58 0.47 0.47 470 -06 -07 190 FN 2060A-16-.. 16 (18.4) 0.074 0.65 0.33 0.47 1000 -06 -07 -08 260 FN 2060A-20-.. 20 (23) 0.074 0.6 1 0.47 220 -06 -08 480 FN 2060A-30-08 30 (34.5) 0.074 0.6 1 0.47 220 -08 950 FN 2060B-1-.. 1 (1.2) 0.002 12 0.22 1000 -06 -07 120 FN 2060B-3-.. 3 (3.5) 0.002 2.5 0.22 1000 -06 -07 120 FN 2060B-6-.. 6 (6.9) 0.002 0.97 0.22 1000 -06 -07 120 FN 2060B-10-.. 10 (11.5) 0.002 0.8 0.47 470 -06 -07 190 FN 2060B-12-.. 12 (13.8) 0.002 0.58 0.47 470 -06 -07 190 FN 2060B-16-.. 16 (18.4) 0.002 0.65 0.33 1000 -06 -07 -08 260 FN 2060B-20-.. 20 (23) 0.002 0.6 1 220 -06 -08 480 FN 2060B-30-08 30 (34.5) 0.002 0.6 1 220 -08 950 ** To compile a complete part number, please replace the -.. with the required I/O connection style (e.g. FN 2060-30-08, FN 2060B-10-06). ** Maximum leakage under normal operating conditions. Note: if the neutral line is interrupted, worst case leakage could reach twice this level. Typical filter attenuation dPer CISPR 17 A = 50 /50 sym B = 50 /50 asym C = 0.1 /100 sym D = 100 /0.1 sym 1 A types 3 to 12 A types 16 A types 20 and 30 A types