DATASHEET Two-Stage Filters FN2080 Multi-stage High Performance AC/DC EMI Filter Rated currents from 1 to 16 A Approvals & Compliances High differential and common-mode attenuation Good low frequency attenuation Optional medical versions (B type) Optional safety versions (A type) Features and benefits FN 2080 two-stage filters are designed for easy and Performance indicators fast chassis mounting FN 2080 B versions without capacitors to earth comply to 1MOP for ME (medical equipment) acc. IEC 60601-1 FN 2808 A version with low capacitance to earth for safety critical applications with necessity for low leakage currents All filters provide a high conducted attenuation performance, based on chokes with high saturation resistance and excellent thermal behavior FN 2080 two-stage filters are designed with good low frequency attenuation FN 2080 filters are also available as single- stage Technical specifications filters FN 2080 filters are also available with two common Rated voltage* 250 VAC, 50/60 Hz 250 VDC mode choke configuration (FN 2070 series) Operating frequency DC to 400 Hz Various terminal options allow you to select the 1 to 16 A 40C max. Rated currents desired connection style High potential test voltage P > PE 2000 VAC for 2 sec P > PE 2500 VAC for 2 sec (B types) P > N 1100 VDC for 2 sec Temperature range (operation and storage) -25C to +100C (25/100/21)** Typical applications Certified to UL 1283, CSA 22.2 No. 8 1986, IEC/EN 60939 (applies to Electrical and electronic equipment AC and DC applications) Flammability corresponding to Terminal plastic for -06/-08 version: UL 94 V-0 Lighting applications (due to high differential mode Laces for -07 version: UL 94 VW-1 inductance) Grommet for -07 version: UL 94 V-0 Consumer goods Design corresponding to UL 1283, CSA 22.2 No. 8 1986, IEC/EN 60939 Household equipment Overvoltage category II acc. IEC 60664-1 Building automation Pollution degree 2 acc. IEC 60664-1 Industrial applications Altitude 2000m (above derating applies)** MTBF 40C/230 V (Mil-HB-217F) 1,650,000 hours Machinery 1,700,000 hours (B types) Medical equipment Electronic data processing equipment * maximum RMS operating voltage at rated frequency or the maximum DC operating voltage Office automation and datacom equipment ** for dedicated requests exceeding this specification (e.g. -40 C or higher altitude) please contact your local Schaffner Sales office Various noisy applications requiering good filter performance Typical electrical schematic2 EMC/EMI Products Schaffner Group Datasheets 09 Dec 2021 Filter selection table Filter* Buy Rated current Leakage current** Power Loss Inductance*** Capacitance*** Resistance*** Input/Output Weight 40C (25C) 250 VAC/50 Hz 25C/DC L L1 Cx Cy R connections ( 120 VAC/60 Hz) A mA W mH H F nF k g FN2080-1-.. 1 (1.2) 0.66 (0.38) 2.6 22 490 0.33 4.7 1000 -06 -07 200 FN2080-3-.. 3 (3.5) 0.66 (0.38) 3.7 9.8 160 0.47 4.7 470 -06 -07 270 FN2080-6-.. 6 (6.9) 0.66 (0.38) 5.7 7.8 110 1 4.7 220 -06 -07 470 FN2080-10-.. 10 (11.5) 0.66 (0.38) 8.6 4.5 60 1 4.7 220 -06 -07 -08 750 FN2080-12-.. 12 (13.8) 0.66 (0.38) 12.3 3.25 50 1 4.7 220 -06 -07 -08 750 FN2080-16-.. 16 (18.4) 0.66 (0.38) 9.0 2.8 43 1 4.7 220 -06 -07 -08 1020 FN2080A-1-.. 1 (1.2) 0.07 (0.04) 2.6 22 490 0.33 0.47 1000 -06 -07 200 FN2080A-3-.. 3 (3.5) 0.07 (0.04) 3.7 9.8 160 0.47 0.47 470 -06 -07 270 FN2080A-6-.. 6 (6.9) 0.07 (0.04) 5.7 7.8 110 1 0.47 220 -06 -07 470 FN2080A-10-.. 10 (11.5) 0.07 (0.04) 8.6 4.5 60 1 0.47 220 -06 -07 -08 750 FN2080A-12-.. 12 (13.8) 0.07 (0.04) 12.3 3.25 50 1 0.47 220 -06 -07 -08 750 FN2080A-16-.. 16 (18.4) 0.07 (0.04) 9.0 2.8 43 1 0.47 220 -06 -07 -08 1020 FN2080B-1-.. 1 (1.2) 0.00 2.6 22 490 0.33 1000 -06 -07 200 FN2080B-3-.. 3 (3.5) 0.00 3.7 9.8 160 0.47 470 -06 -07 270 FN2080B-6-.. 6 (6.9) 0.00 5.7 7.8 110 1 220 -06 -07 470 FN2080B-10-.. 10 (11.5) 0.00 8.6 4.5 60 1 220 -06 -07 -08 750 FN2080B-12-.. 12 (13.8) 0.00 12.3 3.25 50 1 220 -06 -07 -08 750 FN2080B-16-.. 16 (18.4) 0.00 9.0 2.8 43 1 220 -06 -07 -08 1020 * To compile a complete part number, please replace the -.. with the required I/O connection style (e.g. FN 2080-16-08, FN 2080B-10-06). ** Maximum leakage under usual AC operating conditions (acc. IEC60939-3). Note: if the neutral line is interrupted, worst case leakage could reach twice this level. *** Tolerances apply: Inductance: -30/+50%, Capacitance: 20%, Resistance: 10% Product selector Example: FN2080A-10-06 - A: Safety version (A) - 10 Ampre current - 06: fast-on terminals Distribution inventory Up-to-date inventory levels for global distributors is available at