DATA SHEET DC Filter FN2211HV and FN2210HV Compact high current DC EMC/EMI filter Reduces conducted emissions towards the Approvals & Compliances solar panel Reduces the probability of EMI radiation off the solar panel Helps to prevent premature panel aging Helps to meet international EMC regulations The FN 2211 HV/FN 2210 HV series are the most Most compact standard solution in the compact dedicated high current DC filters for PV industry inverters in the industry and therefore are an optimum fit with most modern PV inverter FN2210 HV without Cy capacitors to ground generation. In addition the filters can be configured in a very flexible way to fulfil customized application requirements. All FN 2211 HV/FN 2210 HV come in unsymmetrical housings, which help to prevent inverse installation and wrong electrical connection. Along with grid- side installed Schaffner AC EMC/EMI filters FN 3311 HV/FN 3310 HV, the DC filters FN 2211 HV/FN 2210 Performance indicators HV are key to meet the stringent international standards for electromagnetic compatibility and help to ensure a reliable and fault-free operation of the entire PV system. Features and Benefits Installed between the PV inverter and the solar panel, the FN 2211 HV and FN 2210 HV DC filters are used to influence positively the conducted emissions on the panel side of the system. Therefore the DC filters significantly reduce the potential for highfrequency (HF) interference radiation of the panel. The filter also helps to Technical Specifications prevent premature panel aging because of HF stray and leakage currents. 1 500 VDC Maximum continuous operating voltage Typical Applications DC Operating frequency 250 to 2300 A 50C Rated currents The FN 2211 HV/FN 2210 HV series are primarily P -> E 6 800 VDC for 2 sec High potential test voltage designed for PV inverter applications between 250 P -> P 3 850 VDC for 2 sec and 2 300 A. However, they can potentially also be IP 00 Protection category applied in other DC applications within published 4x rated current at switch on, max. 8 sec 1.5x rated specifications, like UPS, DC motor drives, energy/ Overload capability current for 1 minute, once per hour -40C battery storage systems, or DC charger to +100C installations. Temperature range (operation and storage) 40/100/21 acc. to IEC 60068-1 Climatic category Ni plated cu bars/Metal Typical electrical schematic Terminals/Housing UL 94V-0 Flammability corresponding to UL 1283, CSA 22.2 No. 8 1986, IEC/EN 60939, Design corresponding to EN 60721-3, EN 62109 > 200,000 hours MTBF Rated amb. Temp./Voltage (Mil- HB-217F)2 DC Filter Schaffner Group DATA SHEET 04. Jul 2022 Filter Selection Table Filters * Rated current Power losss Weight 50C 25C/DC A W kg FN 2211 HV with Cy caps FN 2211HV-250-99-C27-R99 250 9 3.3 400 14 4.2 FN 2211 HV-400-99-C27-R99 FN 2211 HV-600-99-C27-R99 600 15 4.8 1000 31 7.1 FN 2211 HV-1000-99-C27-R99 FN 2211 HV-1500-99-C27-R99 1500 41 12.4 2300 64 18.3 FN 2211 HV-2300-99-C27-R99 FN 2210 HVwithout Cy caps FN 2210 HV-250-99-R9 250 9 2. 400 14 3.3 FN 2210 HV-400-99-R9 FN 2210 HV-600-99-R9 600 15 4.0 1000 31 6.4 FN 2210 HV-1000-99-R9 FN 2210 HV-1500-99-R9 1500 41 11.2 2300 64 17.6 FN 2210 HV-2300-99-R9 * Filters with reduced Cy capacitance to ground for high asymmetrical currents and higher voltages available upon request. Typical Filter Attenuation FN 221x HV-xxx-99-C27-R99 Per CISPR 17 50 / 50 asym 50 / 50 sym