Feedthrough Components FN 761X AC Feedthrough Filter n IEC/EN 60939 approval Approvals n Rated currents from 10 to 250A n 5kV pulse test capability n Class Y2 capacitor Technical specifications Typical electrical schematic C L C Maximum continuous operating voltage: 300VAC, 50/60Hz (ENEC) 250VAC, 50/60Hz (UL) 1000VDC max. Rated currents: 10 to 250A 60C max. Capacitor class: Y2 High potential test voltage: 3000VDC for 2 sec Insulation resistance (100VDC after 60 sec): < 0.33F, R > 15,000M > 0.33F, > 5000s Temperature range (operation and storage): -40C to +100C (40/100/21) Flammability corresponding to: UL 94V-2 or better MTBF 60C/300V (Mil-HB-217F): < 200A: > 675,000 hours 200A: > 494,000 hours Features and benefits Typical applications Feedthrough filters offer a high insertion n Very low internal series inductance. n Power line filter for 110/240VAC power loss across a broad band of frequencies from n Very high self-resonant frequency. lines a few tens of kHz up to the GHz region. In n Self-healing dielectric. n Increasing system and information security general, feedthrough filters offer a higher n High quality and reliability. n Power supplies level of EMI suppression than feedthrough n Through-bulkhead mounting. n Switching and cellular equipment capacitors of the same current rating. This n Anti-twist protection. n Computer servers is particularly relevant to applications where n Custom-specific or dual-versions on n UPS power supplies source impedance is smaller than 50. request. n Medical equipment Different versions are available offering a n Shielded rooms wide selection on operating currents and per- formance levels. AC feedthrough filters are designed and approved for up to 300VAC 50/60Hz operation.> Components > FN 761X Feedthrough selector table Feedthrough Rated current Leakage current* Capacitance** Inductance DC resistance*** Weight 60C 250VAC/50Hz C L 10kHz R 25C A mA nF nH m g FN 7611-10-M3 10 1.89 10 70 1.2 55 FN 7612-10-M3 10 8.86 47 70 1.52 70 FN 7611-16-M4 16 4.15 22 70 0.65 80 FN 7612-16-M4 16 18.85 100 70 0.92 90 FN 7611-32-M4 32 4.15 22 70 0.65 80 FN 7612-32-M4 32 18.85 100 70 0.92 90 FN 7611-63-M6 63 28.3 150 186 0.47 250 FN 7612-63-M6 63 88.6 470 124 0.53 500 FN 7612-100-M8 100 188 1000 124 0.23 750 FN 7611-250-M12 250 88.6 470 169 0.23 1086 * Tolerance +20% ** Tolerance 20% *** Tolerance +15% Typical filter attenuation Full load, 50 system 10A types 16A types 32A types 63A types A = FN 7612-10-M3 B = FN 7611-10-M3 100A types 250A types