Product data sheet 9007TUB4M12 Characteristics LIMIT SWITCH 600VAC 12AMP T +OPTIONS Product availability: Stock - Normally stocked in distribution facility Main Range of product 9007 Series name Severe duty mill Product or component Limit switch type Device application Universal mill switch Device short name 9007T/FT Body type Fixed Head type Rotary head Sale per indivisible 1 quantity Complementary Base plate style Style B Body material Cast zinc Fixing mode By the body Movement of operating head Rotary Type of operator Spring return without operating lever Contact sequence number 4 Function available Neutral position Switch actuation CW and CCW From left or right Type of approach Lateral approach Electrical connection Screw-clamp terminals AWG 22...AWG 12 Cable entry 1 entry for Pg 13.5 DIN 40430 Number of poles 1 Switch function SPDT-DB Contact form Form Z Contact operation Snap action Contacts usage - Contacts material Silver flashed copper Positive opening Without Minimum torque for tripping 12 lbf.in Maximum actuation speed 90 ft/min with 45 cam angle, levers only 130 ft/min with 30 cam angle, levers only Tripping angle 6 Maximum displacement angle 89 Repeat accuracy +/- 0.004 in linear travel of cam on 1.5 in lever arm Contact code designation A600 480 V AC 6.25 A NEMA rating designation A600 240 V AC 12.5 A NEMA rating designation A600 120 V AC 20 A NEMA rating designation P600 600 V DC 0.2 A NEMA rating designation P600 250 V DC 1 A NEMA rating designation P600 120 V DC 5 A NEMA rating designation A600 600 V AC 5 A NEMA rating designation Ithe conventional enclosed thermal current 20 A Ui rated insulation voltage 600 V 3 IEC 609470-1 600 V 3 UL 508 600 V 3 CSA C22.2 No 14 Aug 11, 2019 1 The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein. This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications. It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof. Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein. Uimp rated impulse withstand voltage 2.5 kV AC for 1 minute CE 2.2 kV AC for 1 minute UL 2.64 kV AC for 1 minute CSA Short-circuit protection 20 A Bussmann class CC KTK-R-21 fuse non-time delay Width 2.25 in Height 4.66 in Depth 2.44 in Product weight 2.5 lb(US) Terminals description ISO n1 B (right side contact) A (left side contact) Environment Shock resistance 30 gn 9 ms IEC 60068-2-27 Vibration resistance 10 gn 10...55 Hz IEC 60068-2-6 NEMA degree of protection NEMA 1 Nema type 250 NEMA 2 Nema type 250 NEMA 4 Nema type 250 NEMA 12 Nema type 250 NEMA 13 Nema type 250 IP degree of protection IP67 IEC 60529 Electrical shock protection class Class 0 IEC 61140 Ambient air temperature for operation -10...185 F Ambient air temperature for storage -10...185 F Protective treatment Corrosion resistant gray paint Ordering and shipping details Category 21497 - 9007 FT,T OILTIGHT AND FOUNDRY Discount Schedule DS1 GTIN 00785901000235 Nbr. of units in pkg. 1 Package weight(Lbs) 2.3199999999999998 Returnability Y Country of origin MX Offer Sustainability Sustainable offer status Green Premium product RoHS (date code: YYWW) Compliant - since 1150 - Schneider Electric declaration of conformity Schnei- der Electric declaration of conformity REACh Reference not containing SVHC above the threshold Product environmental profile Available Product end of life instructions Need no specific recycling operations California proposition 65 WARNING: This product can expose you to chemicals including: - - - - - - - Substance 1 Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and - - - - - - - Substance 2 Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. - - - - - - - More information For more information go to www.p65warnings.ca.gov Contractual warranty Warranty period 18 months 2