Product data sheet ATS48D47Y Characteristics soft starter for asynchronous motor - ATS48 - 40 A - 208..690 V - 11..37 KW Product availability: Stock - Normally stocked in distribution facility Main Range of product Altistart 48 Product or component Soft starter type Product destination Asynchronous motors Product specific applica- Heavy duty industry and pumps tion Device short name ATS48 Power supply voltage 208...690 V (- 15...10 %) Motor power kW 11 kW at 230 V for standard applications 22 kW at 400 V for standard applications 22 kW at 440 V for standard applications 22 kW at 500 V for severe applications 22 kW at 525 V for severe applications 30 kW at 500 V for standard applications 30 kW at 525 V for standard applications 30 kW at 660 V for severe applications 30 kW at 690 V for severe applications 37 kW at 660 V for standard applications 37 kW at 690 V for standard applications 9 kW at 230 V for severe applications 18.5 kW at 400 V for severe applications 18.5 kW at 440 V for severe applications Motor power hp 10 hp at 208 V for severe applications 15 hp at 230 V for standard applications 25 hp at 460 V for severe applications 30 hp at 460 V for standard applications 30 hp at 575 V for severe applications 40 hp at 575 V for standard applications Power dissipation in W For standard applications 116 W For standard applications 142 W Utilisation category AC-53A Type of start Start with torque control (current limited to 5 In) Icl nominal current 47 A (connection in the motor supply line) for severe applications 47 A (connection in the motor supply line) for stan- dard applications IP degree of protection IP20 Complementary Assembly style With heat sink Function available External bypass (optional) Power supply voltage limits 177...759 V Power supply frequency 50...60 Hz (- 5...5 %) Power supply frequency limits 47.5...63 Hz Device connection In the motor supply line Factory setting current 40 A Uc control circuit voltage 110 - 15 % to 230 + 10 %, 50/60 Hz Control circuit consumption 30 W Discrete output number 2 Discrete output type (LO1) logic output 0 V common configurable (LO2) logic output 0 V common configurable (R1) relay outputs fault relay NO (R2) relay outputs end of starting relay NO (R3) relay outputs motor powered NO Output absolute accuracy precision +/- 5 % Aug 9, 2019 1 The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein. This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications. It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof. Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein.Minimum switching current Relay outputs 10 mA at 6 V DC Maximum switching current Logic output 0.2 A at 30 V DC Relay outputs 1.8 A at 230 V AC inductive load, cos phi = 0.5, L/R = 20 ms Relay outputs 1.8 A at 30 V DC inductive load, cos phi = 0.5, L/R = 20 ms Discrete input number 5 Discrete input type PTC, 750 Ohm at 77 F (25 C) (Stop, Run, LI3, LI4) logic, <= 8 mA 4300 Ohm Discrete input voltage 24 V (<= 30 V) Discrete input logic Positive logic (Stop, Run, LI3, LI4) state 0 < 5 V and <= 2 mA, state 1 > 11 V and >= 5 mA Starting current Adjustable 0.4...1.3 Icl Analogue output type (AO) current output 0-20 mA or 4-20 mA <= 500 Ohm Communication port protocol Modbus Connector type 1 RJ45 Communication data link Serial Physical interface RS485 multidrop Transmission rate 4800, 9600 or 19200 bps Max nodes number 31 Protection type Phase failure (line) Thermal protection (motor) Thermal protection (starter) Marking CE Type of cooling Forced convection Operating position Vertical +/- 10 degree Height 10.83 in (275 mm) Width 6.3 in (160 mm) Depth 7.48 in (190 mm) Product weight 10.8 lb(US) (4.9 kg) Motor power range AC-3 7...11 kW at 200...240 V 3 phases 15...25 kW at 380...440 V 3 phases 15...25 kW at 480...500 V 3 phases 30...50 kW at 480...500 V 3 phases Motor starter type Soft starter Environment Electromagnetic compatibility Conducted and radiated emissions conforming to IEC 60947-4-2 level A Conducted and radiated emissions conforming to IEC 60947-4-2 level B Damped oscillating waves conforming to IEC 61000-4-12 level 3 Electrostatic discharge conforming to IEC 61000-4-2 level 3 Immunity to electrical transients conforming to IEC 61000-4-4 level 4 Immunity to radiated radio-electrical interference conforming to IEC 61000-4-3 level 3 Voltage/current impulse conforming to IEC 61000-4-5 level 3 Standards EN/IEC 60947-4-2 Product certifications CCC DNV TCF C-Tick NOM 117 UL CSA GOST SEPRO Vibration resistance 1 gn (f = 13...200 Hz) conforming to EN/IEC 60068-2-6 1.5 mm (f = 2...13 Hz) conforming to EN/IEC 60068-2-6 Shock resistance 15 gn 11 ms conforming to EN/IEC 60068-2-27 Noise level 52 dB Pollution degree Level 3 conforming to IEC 60664-1 Relative humidity 0...95 % without condensation or dripping water conforming to EN/IEC 60068-2-3 Ambient air temperature for operation 40...60 C with current derating of 2 % per C 14...104 F (-10...40 C) without derating 2