Product data sheet XB5AK134B5 Characteristics red complete illuminated selector switch 22 3- position stay put 1NO+1NC 24V Main Range of product Harmony XB5 Product or component type Complete illuminated selector switch Device short name XB5 Bezel material Plastic Mounting diameter 0.87 in (22 mm) Sale per indivisible quantity 1 Shape of signaling unit head Round Type of operator Stay put Operator profile Red standard handle Operator position information 3 positions +/- 45 Contacts type and composition 1 NO + 1 NC Contact operation Slow-break Connections - terminals Screw clamp terminals: <= 2 x 1.5 mm with cable end conforming to EN/IEC 60947-1 Screw clamp terminals: >= 1 x 0.22 mm without cable end conforming to EN/IEC 60947-1 Bulb base Integral LED Us rated supply voltage 24 V AC/DC, 50/60 Hz Complementary Height 1.65 in (42 mm) Width 1.18 in (30 mm) Depth 2.76 in (70 mm) Terminals description ISO n1 (13-14)NO (11-12)NC Product weight 1.14 lb(US) (0.516 kg) Resistance to high pressure washer 1015.26 psi (7000000 Pa) at 131 F (55 C),distance: 0.1 m Contacts usage Standard contacts Positive opening With positive opening conforming to EN/IEC 60947-5-1 appendix K Operating torque 1.24 lbf.in (0.14 N.m) (NO changing electrical state) Mechanical durability 1000000 cycles Tightening torque 7.08...10.62 lbf.in (0.8...1.2 N.m) conforming to EN 60947-1 Shape of screw head Cross head compatible with Philips no 1 screwdriver Cross head compatible with pozidriv No 1 screwdriver Nov 07, 2017 1 Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applicationsSlotted head compatible with flat 4 mm screwdriver Slotted head compatible with flat 5.5 mm screwdriver Contacts material Silver alloy (Ag/Ni) Short-circuit protection 10 A cartridge fuse type gG conforming to EN/IEC 60947-5-1 Ith conventional free air thermal 10 A conforming to EN/IEC 60947-5-1 current Ui rated insulation voltage 600 V (degree of pollution: 3) conforming to EN 60947-1 Uimp rated impulse withstand voltage 6 kV conforming to EN 60947-1 Ie rated operational current 3 A at 240 V, AC-15, A600 conforming to EN/IEC 60947-5-1 6 A at 120 V, AC-15, A600 conforming to EN/IEC 60947-5-1 0.1 A at 600 V, DC-13, Q600 conforming to EN/IEC 60947-5-1 0.27 A at 250 V, DC-13, Q600 conforming to EN/IEC 60947-5-1 0.55 A at 125 V, DC-13, Q600 conforming to EN/IEC 60947-5-1 1.2 A at 600 V, AC-15, A600 conforming to EN/IEC 60947-5-1 Electrical durability 1000000 cycles, AC-15, 2 A at 230 V, operating rate: 3600 cyc/h, load factor: 0.5 conforming to EN/ IEC 60947-5-1 appendix C 1000000 cycles, AC-15, 3 A at 120 V, operating rate: 3600 cyc/h, load factor: 0.5 conforming to EN/ IEC 60947-5-1 appendix C 1000000 cycles, AC-15, 4 A at 24 V, operating rate: 3600 cyc/h, load factor: 0.5 conforming to EN/ IEC 60947-5-1 appendix C 1000000 cycles, DC-13, 0.2 A at 110 V, operating rate: 3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C 1000000 cycles, DC-13, 0.5 A at 24 V, operating rate: 3600 cyc/h, load factor: 0.5 conforming to EN/ IEC 60947-5-1 appendix C Electrical reliability < 10exp(-6) at 5 V, 1 mA in clean environment conforming to EN/IEC 60947-5-4 < 10exp(-8) at 17 V, 5 mA in clean environment conforming to EN/IEC 60947-5-4 Signalling type Steady Light source Protected LED Supply voltage limits 19.2...30 V DC 21.6...26.4 V AC Current consumption 18 mA Service life 100000 h at rated voltage and 25 C Surge withstand 1 kV conforming to IEC 61000-4-5 Environment Protective treatment TH Ambient air temperature for storage -40...158 F (-40...70 C) Ambient air temperature for operation -40...158 F (-40...70 C) Electrical shock protection class Class II conforming to IEC 60536 IP degree of protection IP69 IP66 conforming to IEC 60529 IP67 conforming to IEC 60529 IP69K NEMA degree of protection NEMA 13 NEMA 4X IK degree of protection IK05 conforming to IEC 50102 Standards UL 508 JIS C 4520 EN/IEC 60947-5-1 EN/IEC 60947-5-4 CSA C22.2 No 14 EN/IEC 60947-1 Product certifications UL GL BV RINA LROS (Lloyds register of shipping) DNV CSA Vibration resistance 5 gn (f = 2...500 Hz) conforming to IEC 60068-2-6 Shock resistance 30 gn (duration = 18 ms) half sine wave acceleration conforming to IEC 60068-2-27 50 gn (duration = 11 ms) half sine wave acceleration conforming to IEC 60068-2-27 Resistance to fast transients 2 kV conforming to IEC 61000-4-4 2