Product data sheet XCKS159H29 Characteristics limit switch XCKS - thermoplastic round rod lever 6 mm - 1NO+1NC - snap - M20 Main Range of product OsiSense XC Series name Standard format Product or component Limit switch type Device short name XCKS Sensor design Form D conforming to CENELEC EN 50041 Body type Fixed Head type Rotary head Material Plastic Fixing mode By the body Movement of operating Rotary head Type of operator Thermoplastic spring return round rod lever (round rod 6 mm, L = 200 mm) Type of approach 1 or 2 programmable direction lateral approach Electrical connection Screw-clamp terminals , clamping capacity: 1 x 0.34...2 x 1.5 mm Cable entry 1 entry tapped for M20 x 1.5 cable gland , cable out- er diameter: 7...13 mm Number of poles 2 Contacts type and com- 1 NO + 1 NC position Contacts operation Snap action Positive opening Without Complementary Body material Plastic Head material Plastic Switch actuation By any moving part Contacts insulation form Zb Number of steps 1 Minimum torque for tripping 0.15 N.m Minimum actuation speed 0.01 m/min Maximum actuation speed 1 m/s Contact code designation A300 , AC-15 (Ue = 240 V , Ie = 3 A) conforming to EN/IEC 60947-5-1 appendix A Q300 , DC-13 (Ue = 250 V , Ie = 0.27 A) conforming to EN/IEC 60947-5-1 ap- pendix A Ithe conventional enclosed thermal current 10 A AC Ui rated insulation voltage 300 V conforming to UL 508 300 V conforming to CSA C22-2 No 14 500 V degree of pollution 3 conforming to IEC 60947-1 Resistance across terminals 25 mOhm conforming to IEC 60255-7 category 3 Uimp rated impulse withstand voltage 6 kV conforming to IEC 60947-1 6 kV conforming to IEC 60664 Short circuit protection 10 A by gG cartridge fuse Electrical durability 5000000 cycles , DC-13 inductive load type, 48 V , 7 W , load factor: 0.5 , operat- ing rate: 60 cyc/mn 5000000 cycles , DC-13 inductive load type, 120 V , 4 W , load factor: 0.5 , oper- ating rate: 60 cyc/mn 5000000 cycles , DC-13 inductive load type, 24 V , 10 W , load factor: 0.5 , oper- ating rate: 60 cyc/mn Jan 10, 2017 1 The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein. This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications. It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof. Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein.Mechanical durability 20000000 cycles Width 40 mm Height 72.5 mm Depth 36 mm Product weight 0.15 kg Environment Shock resistance 50 gn (duration = 11 ms) conforming to IEC 60068-2-27 Vibration resistance 25 gn (f = 10...500 Hz) conforming to IEC 60068-2-6 IP degree of protection IP65 conforming to IEC 60529 IK degree of protection IK03 conforming to EN 50102 Class of protection against electric shock Class II conforming to IEC 61140 Class II conforming to NF C 20-030 Ambient air temperature for operation -25...70 C Ambient air temperature for storage -40...70 C Protective treatment TC Product certifications CCC CSA UL Standards CENELEC EN 50041 CSA C22-2 No 14 EN 60204-1 EN 60947-5-1 IEC 60204-1 IEC 60947-5-1 UL 508 RoHS EUR conformity date 4Q2009 RoHS EUR status Will be compliant 2