Product data sheet XCSE7311 Characteristics metal safety switch XCSE - 2NC+1NO - slow break - 2 entries tapped Pg 13- 24V Product availability: Stock - Normally stocked in distribution facility Main Range of product Preventa Safety detection Product or component Safety switch type Component name XCSE Design Rectangular Material Metal Head type Key operated turret head Contacts type and com- 2 NC + 1 NO position Contact operation Slow-break, break before make Solenoid contacts type 1 NC + 1 NO (slow-break, simultaneous) and composition Cable entry 2 entries tapped Pg 13.5 Electromagnet interlock- Locking on de-energisation and unlocking on energi- ing sation of solenoid Us solenoidratedsupply 24 V (- 20...10 %) voltage Cable outer diameter 0.35...0.47 in (9...12 mm) Electrical connection Terminal, 1 x 0.5...2 x 1.5 mm with or without cable end Number of poles 3 Locking options descrip- With interlocking, locking by solenoid tion Local signalling 2 LEDs green or orange (guard open/guard closed and locked) Signalling circuit voltage 24/48 V (voltage limits: 20...52 V) Complementary Positive opening With NC contact Supply voltage type AC/DC Supply frequency 50/60 Hz Load factor 1 Power consumption in VA 10 VA (inrush) 10 VA (sealed) Signalling circuit type AC/DC Signalling circuit consumption 7 mA Mechanical durability >= 1000000 cycles Minimum actuation speed 0.03 ft/s (0.01 m/s) Maximum actuation speed 1.64 ft/s (0.5 m/s) Ie rated operational current 0.55 A at 125 V utilisation category DC-13, Q300 conforming to EN/IEC 60947-5-1 0.27 A at 250 V utilisation category DC-13, Q300 conforming to EN/IEC 60947-5-1 3 A at 120 V utilisation category AC-15, B300 conforming to EN/IEC 60947-5-1 1.5 A at 240 V utilisation category AC-15, B300 conforming to EN/IEC 60947-5-1 Ithe conventional enclosed thermal current 6 A Ui rated insulation voltage 50 V for signalling circuit conforming to EN/IEC 60947-1 Uimp rated impulse withstand voltage 6 kV conforming to EN/IEC 60947-5-1 Protection type Overvoltage protection signalling circuit Short-circuit protection 10 A cartridge fuse type gG (gl) Actuator forcible withdrawal rtc 2000 N Aug 10, 2019 1 The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein. This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications. It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof. Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein.Actuator force for extraction >= 20 N Operating rate 10 cyc/mn for maximum durability Safety level Can reach category 4 with the appropriate monitoring system and correctly wired conforming to EN/ISO 13849-1 Can reach PL = e with the appropriate monitoring system and correctly wired conforming to EN/ISO 13849-1 Can reach SIL 3 with the appropriate monitoring system and correctly wired con- forming to EN/IEC 61508 Safety reliability data B10d = 5000000 (value given for a life time of 20 years limited by mechanical or contact wear) Body material Zamak Head material Zamak Depth 1.73 in (44 mm) Height 5.75 in (146 mm) Width 3.86 in (98 mm) Product weight 2.51 lb(US) (1.14 kg) Environment Standards EN 1088/ISO 14119 EN/IEC 60204-1 EN/IEC 60947-5-1 EN/ISO 12100 UL 508 CSA C22.2 No 14 Product certifications CSA UL Protective treatment TC Ambient air temperature for operation -13...104 F (-25...40 C) Ambient air temperature for storage -40...158 F (-40...70 C) Vibration resistance 5 gn (f = 10...500 Hz) conforming to IEC 60068-2-6 Shock resistance 10 gn 11 ms conforming to IEC 60068-2-27 Electrical shock protection class Class I conforming to EN/IEC 61140 IP degree of protection IP67 conforming to EN/IEC 60529 and EN/IEC 60947-5-1 Ordering and shipping details Category 22411 - LIMIT SWITCHES,IEC,XCKJ Discount Schedule T GTIN 00785901164791 Nbr. of units in pkg. 1 Package weight(Lbs) 2.8399999999999999 Returnability Y Country of origin ID Offer Sustainability RoHS (date code: YYWW) Compliant - since 1345 - Schneider Electric declaration of conformity Schnei- der Electric declaration of conformity REACh Reference not containing SVHC above the threshold Product end of life instructions Available California proposition 65 WARNING: This product can expose you to chemicals including: - - - - - - - Substance 1 Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and - - - - - - - Substance 2 Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. - - - - - - - More information For more information go to www.p65warnings.ca.gov Contractual warranty Warranty period 18 months 2