Product data sheet XMLPM09BD11VQ Characteristics pressure transmitter - XMLP - -1+9bar - G1/4A male - 0,5..4,5V - M12 - set of 40 Main Range of product OsiSense XM Product or component Electronic pressure sensors type Pressure sensor type Pressure transmitter Pressure sensor name XMLP Electrical circuit type Control circuit Pressure sensor size -1...9 bar Local display Without Controlled fluid Air -20...120 C Fresh water 0...120 C Hydraulic oil -20...120 C Gas -20...120 C Refrigeration fluid -20...120 C Fluid connection type G 1/4A (male) conforming to DIN 3852-E Electrical connection 1 male connector M12 4 pins Us rated supply volt- 5 V DC SELV, voltage limits: 4.5...5.5 V age Current consumption < 5 mA Type of output signal Analogue Analogue output func- 0.5...4.5 V, 3-wire tion Quantity per set Set of 40 Type of packing Group Complementary Pressure setting range -1...9 bar Maximum permissible accidental pressure 20 bar Destruction pressure 100 bar Materials in contact with fluid Stainless steel type 17-4PH Stainless steel type AISI 304 Fluorocarbon FKM (Viton) Operating position Any position Protection type Load short-circuit Reverse polarity Electromagnetic compatibility Susceptibility to electromagnetic fields conforming to EN/IEC 61000-4-3 - test lev- el 10 V/m (f = 80...1000 MHz) Electrical fast transient/burst immunity test conforming to EN/IEC 61000-4-4 - test level 2 kV 1.2/50 s shock waves immunity test conforming to EN/IEC 61000-4-5 - test level 500 V 12 Ohm, 1 kV 42 Ohm Radiated RF fields conforming to EN/IEC 61000-4-6 - test level 10 V (f = 0.15...80 MHz) Electrostatic discharge immunity test conforming to EN/IEC 61000-4-2 - test level 8 kV air, 4 kV contact Uimp rated impulse withstand voltage 0.5 kV Response time on output < 5 ms Measurement accuracy +/- 0.5 % of the measuring range Repeat accuracy +/- 0.1 % of the measuring range Mechanical durability >= 10000000 cycles Product weight 0.05 kg Diameter 30 mm Length 26 mm Nov 4, 2016 1 The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein. This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications. It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof. Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein.Environment Standards CE EN/IEC 61326-1 Product certifications CULus RCM EAC Protective treatment TC Ambient air temperature for operation -30...100 C Ambient air temperature for storage -30...100 C Vibration resistance 20 gn (f = 10...2000 Hz) conforming to EN/IEC 60068-2-64 Shock resistance 25 gn for 11 ms conforming to EN/IEC 60068-2-27 IP degree of protection IP65 conforming to EN/IEC 60529 IP67 conforming to EN/IEC 60529 IP69K conforming to DIN 40050 2