Product data sheet Specifications Safety module, Harmony Safety Automation, Zero speed monitoring with time delay, 24V AC/DC, screw XPSUVN11AP Product availability : Stock - Normally stocked in distribution facility Main Harmony Safety Automation Range of Product Product or Component Type Safety module Safety module name XPSUVN Safety module application For zero speed detection Function of module Monitoring 3-phase motor Monitoring 3-phase motor with star-delta starting Monitoring 3-phase motor with variable number of poles Monitoring 3-phase motor with variable number of poles and star-delta starting Monitoring dc motor Monitoring servo motor Monitoring 3-phase motor supplied by variable speed drive Monitoring 3-phase motor supplied by servo drive Controlling enegization to open of guard switch type XCSE, XCSLE, XCSLF, XCST Can reach PL e/category 3 for normally open relay contact ISO 13849-1 Safety level Can reach SILCL 3 for normally open relay contact IEC 62061 Can reach SIL 3 for normally open relay contact IEC 61508 MTTFd > 30 years ISO 13849-1 Safety reliability data Dcavg = 98.9 % ISO 13849-1 PFHd = 2.39E-9 1/h ISO 13849-1 HFT = 1 IEC 62061 PFHd = 2.39E-9 1/h IEC 62061 SFF > 99% IEC 62061 HFT = 1 IEC 61508-1 PFHd = 2.39E-9 1/h IEC 61508-1 SFF > 99% IEC 61508-1 Type = B IEC 61508-1 Product certications TV cULus 24 V AC - 15...10 % Us Rated Supply Voltage 24 V DC - 20...20 % Output type Relay, 1 NO, volt-free Number of additional circuits 2 solid state outputs Complementary 2.0W Power Consumption in W 5.5VA Power Consumption in VA 690 V Input voltage 50 mV Input detection threshold 65 mV 85 mV 110 mV 140 mV 180 mV 230 mV 300 mV Mar 8, 2022 1 Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications400 mV 500 mV Time delay 0.5 s 1 s 2 s 3 s 5 s 8 s 12 s 20 s 35 s 60 s 5A AC-1 Ie rated operational current 3A AC-15 5A DC-1 3A DC-13 Ith conventional free air 6A NO relay output circuit thermal current Associated fuse rating 6A gG relay output IEC 60947-1 Standards IEC 60947-5-1 IEC 61508-1 functional safety standard IEC 61508-2 functional safety standard IEC 61508-3 functional safety standard IEC 61508-4 functional safety standard IEC 61508-5 functional safety standard IEC 61508-6 functional safety standard IEC 61508-7 functional safety standard ISO 13849-1 functional safety standard IEC 62061 functional safety standard 10mA relay output Minimum output current 5V relay output Minimum output voltage 690V phase to phase 2)EN/IEC 60947-1 Ui rated insulation voltage 400V phase to earth 2)EN/IEC 60947-1 4kV II EN/IEC 60947-1 Uimp rated impulse withstand voltage LED green power power ON Local signalling LED red error error LED yellow state status LED yellow L12 input line comparison LED yellow L32 input line comparison Connections - terminals Removable screw terminal block solid or flexible 0.2...2.5 mm Removable screw terminal block flexible with ferrule 0.25...2.5 mm single conductor Removable screw terminal block solid or flexible 0.2...1.5 mm twin conductor Removable screw terminal block flexible with ferrule 2 x 0.25...1 mm without cable end, with bezel Removable screw terminal block flexible with ferrule 2 x 0.5...1.5 mm with cable end, with bezel Mounting Support 35 mm symmetrical DIN rail Depth 4.72in (120mm) 3.94in (100mm) Height 0.89in (22.5mm) Width 0.44lb(US) (0.2kg) Net weight Environment IP degree of protection IP20 terminals)EN/IEC 60529 IP40 housing)EN/IEC 60529 IP54 mounting area)EN/IEC 60529 Ambient Air Temperature for -13131F (-2555C) Operation -40158F (-4070C) Ambient Air Temperature for Storage 595% non-condensing Relative Humidity Ordering and shipping details 22477-SAFETY MODULES (PREVENTA) Category SAF2 Discount Schedule 2 Mar 8, 2022