Product data sheet Specifications Safety module, Harmony Safety Automation, Zero speed monitoring with time delay, 48-240 V AC/DC, screw XPSUVN31AP Product availability : Stock - Normally stocked in distribution facility Main Harmony Safety Automation Range of Product Safety module Product or Component Type XPSUVN Safety module name For zero speed detection Safety module application Monitoring 3-phase motor Function of module Monitoring 3-phase motor with star-delta starting Monitoring 3-phase motor with variable number of poles Monitoring 3-phase motor with variable number of poles and star-delta starting Monitoring dc motor Monitoring servo motor Monitoring 3-phase motor supplied by variable speed drive Monitoring 3-phase motor supplied by servo drive Controlling enegization to open of guard switch type XCSE, XCSLE, XCSLF, XCST Can reach PL e/category 3 for normally open relay contact ISO 13849-1 Safety level Can reach SILCL 3 for normally open relay contact IEC 62061 Can reach SIL 3 for normally open relay contact IEC 61508 MTTFd > 30 years ISO 13849-1 Safety reliability data Dcavg = 98.9 % ISO 13849-1 PFHd = 2.44E-9 1/h ISO 13849-1 HFT = 1 IEC 62061 PFHd = 2.44E-9 1/h IEC 62061 SFF > 99% IEC 62061 HFT = 1 IEC 61508-1 PFHd = 2.44E-9 1/h IEC 61508-1 SFF > 99% IEC 61508-1 Type = B IEC 61508-1 TV Product certications cULus Us Rated Supply Voltage 48...240 V AC/DC - 10...10 % Relay, 1 NO, volt-free Output type 2 solid state outputs Number of additional circuits Complementary Power Consumption in W 2.5W Power Consumption in VA 5.5VA Input voltage 690 V Input detection threshold 50 mV 65 mV 85 mV 110 mV 140 mV 180 mV Mar 8, 2022 1 Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications230 mV 300 mV 400 mV 500 mV 0.5 s Time delay 1 s 2 s 3 s 5 s 8 s 12 s 20 s 35 s 60 s 5A AC-1 Ie rated operational current 3A AC-15 5A DC-1 3A DC-13 6A NO relay output circuit Ith conventional free air thermal current Associated fuse rating 6A gG relay output IEC 60947-1 Standards IEC 60947-5-1 IEC 61508-1 functional safety standard IEC 61508-2 functional safety standard IEC 61508-3 functional safety standard IEC 61508-4 functional safety standard IEC 61508-5 functional safety standard IEC 61508-6 functional safety standard IEC 61508-7 functional safety standard ISO 13849-1 functional safety standard IEC 62061 functional safety standard 10mA relay output Minimum output current 5V relay output Minimum output voltage 690V phase to phase 2)EN/IEC 60947-1 Ui rated insulation voltage 400V phase to earth 2)EN/IEC 60947-1 Uimp rated impulse withstand 4kV II EN/IEC 60947-1 voltage LED green power power ON Local signalling LED red error error LED yellow state status LED yellow L12 input line comparison LED yellow L32 input line comparison Connections - terminals Removable screw terminal block solid or flexible 0.2...2.5 mm Removable screw terminal block flexible with ferrule 0.25...2.5 mm single conductor Removable screw terminal block solid or flexible 0.2...1.5 mm twin conductor Removable screw terminal block flexible with ferrule 2 x 0.25...1 mm without cable end, with bezel Removable screw terminal block flexible with ferrule 2 x 0.5...1.5 mm with cable end, with bezel 35 mm symmetrical DIN rail Mounting Support 4.72in (120mm) Depth 3.94in (100mm) Height 0.89in (22.5mm) Width 0.44lb(US) (0.2kg) Net weight Environment IP degree of protection IP20 terminals)EN/IEC 60529 IP40 housing)EN/IEC 60529 IP54 mounting area)EN/IEC 60529 Ambient Air Temperature for -13131F (-2555C) Operation Ambient Air Temperature for -40158F (-4070C) Storage Relative Humidity 595% non-condensing Ordering and shipping details 22477-SAFETY MODULES (PREVENTA) Category 2 Mar 8, 2022