Digital Access Keypad Manual User Operation for the SK-1011-SQ n n n n Note: indicates 1. Using the User Codes: the inhibit code. A. User codes operate the door (4-8 digits long). u u u u Note: indicates ENFORCER u u u u Press the user code. B. The key must also be pressed if he keypad is in manual-entry mode. Note: indicatesX X X X u u u u Press the master code. SK-1011-SQ 2. Using the Master Code: The Master Code can be used to operate the door or program the keypad (4-8 digits long, see pt. 4 below). Digital Access Keypad A. To operate the relay output: X X X X 1 Press with 5A Relay Output B. Inhibit/lockout code: X X X X 2 Press 3. Using the Inhibit/Lockout Code: MANUAL A. Inhibit/lockout codes temporarily lock the keypad. (4-8 digits long, see pg. 5 for more information) n n n n Press B. The key must be pressed also if he keypad is in manual-entry mode. n n n n Press 4. User Code and Master Code Programming: A. Enter the Master Code first, followed by the key * (If you forgot the master code, see page 7 for more information.) X X X X Press * B. Change/Add/Delete User or Master Codes: u u u u 1 Press 00-99 (user ID) (user code, 4-8 digits) C. Deleting Individual Users: Press 00-99 (user ID) 1 D. Changing the Master Code: X X X X Press 0 E. To exit programming mode, press the key . * LIFETIME LIMITED WARRANTY This SECO-LARM product is warranted against defects in material and workmanship while used in normal service for the lifetime of the product. SECO-LARMs obligation is limited to the repair or replacement of any defective part if the unit is returned, transportation prepaid, to SECO-LARM. Under no circumstances will SECO-LARM be responsible for any costs or charges for removal, installation, or reinstallation. This Warranty is void if damage is caused by or attributed to acts of God, physical or electrical misuse or abuse, neglect, repair, or alteration, improper or abnormal usage, or faulty installation, or if for any other reason SECO-LARM determines that such equipment is not operating properly as a result of causes other than defects in material and Also available from SECO-LARM: workmanship. The sole obligation of SECO-LARM, and the purchasers exclusive remedy, shall be limited to repair or replacement only, at SECO-LARMs option. In no event shall SECO-LARM be liable for any special, collateral, incidental, or consequential personal or property Outdoor Keypads Indoor Keypad damages of any kind to the purchaser or anyone else. This lifetime limited warranty is for products sold and installed in the United States and Canada. For all other countries the warranty is 1 (one) year. NOTICE: The information and specifications printed in this manual are current at the time of publication. However, the SECO-LARM policy is one of continual development and improvement. For this reason, SECO-LARM reserves the right to change specifications without notice. SECO-LARM is also not responsible for misprints or typographical errors. Copyright 2010 SECO-LARM U.S.A., Inc. All rights reserved. This material may not be reproduced or copied, in whole or in part, without the written permission of SECO-LARM. SECO-LARM U.S.A., Inc. 16842 Millikan Avenue, Irvine, CA 92606 SK-1131-SQ SK-1123-SQ SK-1123-FQ SK-2323-SDQ SK-1323-SDQ Website: www.seco-larm.com PIHAK1 Tel: 800-662-0800 / 949-261-2999 Fax: 949-261-7326 E-mail: sales seco-larm.com MiSK-1011-SQ 092810.pmd SECO-LARM SECO-LARM U.S.A., Inc. Note: Model numbers that end with or that have a round green sticker signify RoHS-compliant products. Page 8Digital Access Keypad Manual Digital Access Keypad Manual TABLE OF CONTENTS REPROGRAM THE KEYPAD (CERTAIN DATA) To change certain data in the keypad (such as to delete or change user codes), do the following: Introduction ................................................................................................................ 2 1. Enter program mode by keying in the master code and the key: * Unique features ......................................................................................................... 2 X X X X The keypad is now in the programming mode. * Specifications ............................................................................................................ 3 2. Make any changes to the keypad s data as noted in the various programming instructions. Wiring -- sample installation ..................................................................................... 3 3. Exit the programming mode by pressing the key. * Preparing to program the keypad ............................................................................. 4 REPROGRAM THE KEYPAD (COMPLETE DATA REFRESH) Getting started ........................................................................................................... 4 Sometimes it may be necessary to completely erase all current data (except the master code) and input new data. An Programming notes .................................................................................................. 4 example of when this may be necessary is the sale of a protected building to a new owner. In such a situation, do the User programming ..................................................................................................... 5 following: 1. Enter the programming mode by keying in the master code and the key, then enter the refresh code, 8 9 0 1 Buzzer and LED signals ............................................................................................ 5 * and the key: LED indicators ........................................................................................................... 5 X X X X The keypad is now in the programming mode. * Installer programming ............................................................................................... 6 8 9 0 1 All old data is cleared, and the keypad is ready for new data.* User code worksheet ................................................................................................. 6 NOTE: The master code does NOT change. Reprogram the keypad (certain data) ....................................................................... 7 2. Use the programming instructions on page 5 to enter the keypad s data. Reprogram the keypad (complete data refresh) ....................................................... 7 3. Exit the programming mode by pressing the key. * Delete user ................................................................................................................ 7 DELETE USER Master code bypass (DAP jumper) ........................................................................... 7 To delete a user who has left the company or who no longer has authority to enter the protected area: User operation ........................................................................................................... 8 1. Enter program mode by keying in the master code and the key: * X X X X The keypad is now in the programming mode. * 2. Enter the output and user ID number and the key: 1 0 5 To delete user ID 05, press INTRODUCTION 3. Exit the programming mode by pressing the key * The SK-1011-SQ is the ideal keypad for office, commercial, and home security installations. This self- contained security keypad has a built-in 5-Amp relay output for maximum flexibility when connecting to MASTER CODE BYPASS (DAP jumper) electronic door strikes, door alarms, door chimes, alarm control panels, or other security and access control If the master code is forgotten or does not work, use the DAP (direct access to program) jumper to override the forgotten applications. The output can be programmed for timed (1-999 seconds) or ON/OFF operation. code and permit direct entry into the programming mode as follows: The SK-1011-SQ output can be programmed for up to 100 4-digit to 8-digit user codes. All programming and 1. Disconnect the power supply. code information is stored in non-volatile EEPROM memory to protect the data in case of power loss. 2. Move the DAP jumper from OFF to ON. 3. Reconnect the power supply. The keypad will start beeping. 4. Move the DAP jumper back to the OFF position. The keypad will UNIQUE FEATURES stop beeping as soon as the jumper is removed. ON OFF 12-24V AC/DC universal power -- No programming or jumpers needed. 5. The keypad is now in the programming mode, ready to receive Relay output inhibit control / lockout mode -- The relay output is typically used for a door strike. If the new programming data. keypad is set to theinhibite mode, the relay output will not operate. This increases the security of the Relay 6. Re-program the keypad as shown starting on page 5. protected premises during the time it is not expected to be occupied, such as during evening or weekend hours. NOTE -- A new master code may be programmed to replace the one Tamp Auto or manual code entry checking: that was lost or forgotten. Note that the sequence for replacing the old o Auto code entry checking mode -- When all the user codes have the same number of digits, the master code is as follows: keypad will activate automatically when the code is entered. There is no need to press the key. This is convenient for the users. Option* Key in new code Confirm Exit o Manual code entry checking mode -- The user codes can vary in number of digits, and the user must press 0 X X X X * the key when finished entering the code. This increases security. *Zero0 is for new master code only see page 5 or 6 for other options. Easily delete user codes -- The administrator can delete individual codes without knowing them. SECO-LARM U.S.A., Inc. Page 2 Page 7 EG In - Egress DAP N.O. C. N.C. (-) AC/DC (+) AC/DC DAP