5011 SERIES 1/2 DISC, HERMETICALLY SEALED THERMOSTAT Introduction Designed to meet demanding shock and vibration requirements, the 5011 series thermostat is a RoHS compliant, positive snap action, single pole / single throw, hermetically sealed unit. Normally supplied with a grounded case construction, an additional terminal can be provided on the case for a positive ground lead or as an isolated device when the unit is insulated from ground. The 5011 series can be used for temperature warning or protection. Calibration is factory set and is tamperproof. Features Hermetic glass seal Ideal for surface and immersion sensing Multiple mounting and terminations available Case isolated and case grounded versions Applications Printed circuit board protections Air or water cooled engines and transmissions Fluid sensing SPECIFICATIONS Cycles Voltage Amps Case Type 100,000 120 3 (resistive) Ground / Insolated case Contact Ratings 100,000 120 2 (inductive) Isolated case 100,000 32 3 (resistive) Grounded case Either close on rise (make) or open on rise (break), SPST (Single Pole, Single Throw) Contact Operations +140F to 480F (+60C to 249C) Operating Temperature Standard of 5F with nominal operating temperature settings in 5F increments Temperature Tolerance -65F to 625F (-53.8C to 329.4C) Long Term Exposure Limit Note: Please consult the factory if lead wire/terminal exposure temperatures are expected to exceed 220F. (Refer to inside notes B & C ) Dielectric Strength 1000 Vrms 60Hz (isolated case) terminals to case (contacts open) Insulated Resistance 50 meghoms at 500 Vdc Thermal Shock MIL-STD-202, Method 107 Test Condition B Cold-rolled steel, nickel plated enclosure with a glass seal. Applications up to 300F have a Mylar sleeve with an epoxy fill, those above 300F have a Nomex sleeve and a high temperature epoxy fill. Materials *Exposure limited should be kept to within 100F of the operating temperature. Consult factory if conditions require otherwise. Page 1 www.sensata.com Copyright 2018 Sensata Technologies, Inc. CONTACT OPERATION CODE DESCRIPTION O Letter O = Open on Rise C Letter C = Close on Rise TERMINAL SELECTION A D J K L M 2 Pan Head Screw Terminals, 8-32 Pan Head Screw Terminal, 8-32 Same as terminal selection L Quick Connect Terminal, Isolated Case Only 2 QC Terminals, Isolated Case Only 2 Leads, Isolated Case Only Grounded Case Only Grounded Case Only See note 1 for lead specifications (304.80 25.40) Except 2 Leads 12.00 1.00 See note 1 for lead specifications (18.16) (15.88) (15.88) (18.16) (18.16) 0.715 0.625 0.625 0.715 0.715 N Same as terminal selection L (609.60 25.40) Except 2 Leads 8-32 Pan Head Screw (x2) 24.00 1.00 8-32 Pan Head Screw 7 Lock Washer (x2) (6.35) 7 Lock Washer (6.35) Quick Connect (152.40 25.40) (Packaged in plastic bag) 2 Quick Connects See note 1 for lead specifications 2 Leads 0.250 (Packaged in plastic bag) 0.250 6.000 1.00 45 10 45 10 P (6.35) Strip Same as terminal selection L .250 Encapsulated (1219.20 25.40) Except 2 Leads 48.00 1.00 (26.97) (26.97) REF (23.80) (15.75) REF See note 1 for lead specifications 1.062 REF (13.84) (23.80) REF 1.062 (13.84) (15.75) (15.75) REF 0.620 0.937 REF REF REF REF 0.937 0.545 0.545 0.620 0.620 Z Special Mounting Mounting Mounting Mounting Mounting Requirements Encapsulated Customer Encapsulated Encapsulated Encapsulated Encapsulated to Specify TEMPERATURE CODES AND TOLERANCE Temperature Scale Fahrenheit Celsius Fahrenheit Celsius Fahrenheit Celsius Top Temperature Settings 140F to 250F 60C to 121.1C 251F to 400F 121.7C to 204.4C 401F to 480F 205C to 248.9C Standard Top Temperature 5F (A) 2.8C (A) 10F (C) 5.6C (C) 25F (N) 13.9C (N) Tolerance (code) Nominal Temperature 25F 13.9C 35F 19.4C 40F 22.2C Differential Note Select any temperature in the range of 140F to 480F. Standard choices fall on the 5F increments, for example 140F, 145F, 150F, 155 F... up to 475F or 480F Specify the F temperature in the part numbering scheme as a three digit code without the F in the part numbe r. For example, for 200F, put in code 200 Bottom Temperature in F equals the Top Temperature in F minus Nominal Differential in F. For example 310F - 30F = 280F A C N Y ( Bottom Temp Only) Tolerance Code F 5F 10F 25F Minimum C 2.8C 5.6C 13.9C Minimum Note The standard tolerance for the top temperature is based on the temperature range the top temperature falls in, please refer to the temperature setting chart, and select the appropriate code for a standard top temperature tolerance For bottom temperature tolerance a Y = minimum trip, which indicates the reset trip occurs at or above the lower temperature set point. Page 2 www.sensata.com Copyright 2018 Sensata Technologies, Inc.