GP1UX31QS Series
Holder-less Type IR Detecting Unit
GP1UX31QS Series
for Remote Control
Features
Outline Dimens ions
(Unit : mm)
1. Holder-less shield case type.
2. Compact type.
Conductive resin(GND)
Strengthened resistance to electromagnetic
3.
2.1 3.2
induction noise by double mold method. 5.5
Operarting voltage 3V type.
4.
Applications
1. AV equipments
1.6
2. Home appliances
3. Toys using IR sensor 1.2
0.4
Absolute Maximum Ratings
V cc
0.5
(Ta=25
*1 G ND
2.54
Parameter Symbol Rating Unit V out
*1
2.54
Supply voltage V V
0 to +6.0
CC
*1
Operating temperature T -10 to +70
opr
Storage temperature T -20 to +70 Example of mounting drawing
stg
from solder side (Reference)
*2
Soldering temperature T 265
sol
*1 No dew condensation is allowed
Top of lenz
*2 For 6s (At mounting on PCB with thickness of 1.6mm)
1. *1 : Indicates root dimensions of connector.
2. Unspecified tolerance:0 .3
Recommended Operating Conditions
Parameter Symbol Operating conditions Unit
Supply voltage V 2.7 to 5.5 V
CC
Notice The content of data sheet is subject to change without prior notice.
In the absence of confirmation by device specification sheets, SHARP takes no responsibility for any defects that may occur in equipment using any SHARP
devices shown in catalogs, data books, etc. Contact SHARP in order to obtain the latest device specification sheets before using any SHARP device.
Sheet No.: OP06013
1
28
7.5
6.9
6.0
8.8
4.1
2.8GP1UX31QS Series
Model Line-up
Diversified models with a different B.P.F. frequency are also available.
Model No.
B.P.F. center frequency Unit
40 GP1UX31QS
36 GP1UX310QS
kHz
38 GP1UX311QS
36.7 GP1UX312QS
Internal Block Diagram
R
L
V
OUT
Limiter B.P.F. Demodulator Integrator Comparator
V
CC
GND
Electro-optical Characteristics
(Ta=25, V CC=3V)
Parameter Symbol Conditions MIN. TYP. MAX. Unit
Dissipation current I No input light 0.27 0.4 mA
CC
*3
High level output voltage V VCC -0.5 V
OH
*3
Low level output voltage V IOL=1.6mA V
OL 0.45
*3
s
High level pulse width T 600 1200
1
*3
Low level pulse width T 400 1000 s
2
*4
B.P.F. center frequency f kHz
0
RL
Output pull-up resistance 70 100 130 k
*3
The burst wave as shown in the following figure shall be transmitted by the transmitter shown in Fig. 1
The carrier frequency of the transmitter, however, shall be same as *4, and measurement shall be from just after starting the transmission until 50 pulse
The B.P.F. center frequency f0 varies with model, as shown in Model Line-up
*4
B urst wave
s 1000s
f =(*4)
0
Duty 50%
Output signal
Sheet No.: OP06013
2