DATA SHEET SKY66423-11: 860 to 930 MHz RF Front-End Module Applications LP-WAN devices Internet of Things Smart meters Logic Industrial applications Control Range extender PA Features TX ANT Integrated PA with +27 dBm output power Integrated LNA with noise figure of 1.5 dB, typical RX LNA Alternate TX input pin simplifies connection to any SoC 204566-001 Transmit bypass path with low loss: < 1.5 dB RX FLT LNA IN Single-ended 50 transmit/receive RF interface Figure 1. SKY66423-11 Block Diagram Fast turn-on/turn-off time: <4 s Rx mode and <2 s Tx mode Supply voltage: 2.0 to 4.8 V Description Sleep mode current: < 1 A The SKY66423-11 is a high-performance, highly integrated RF front-end module designed for high-power Industrial, Scientific, MCM (16-pin, 3.0 x 3.0 x 0.75 mm) NiPdAu plated package Medical (ISM) band applications operating in the 860 to 930 MHz (MSL3, 260 C per JEDEC J-STD-020) frequency range. TM Skyworks Green products are compliant with The SKY66423-11 is designed for ease of use and maximum all applicable legislation and are halogen-free. flexibility with fully matched 50 TX and RX inputs and antenna For additional information, refer to Skyworks outputs, and digital controls compatible with 1.6 to 3.6 V CMOS TM Denition of Green , document number levels. SQ040074. The RF blocks operate over a wide supply voltage range from 2.0 to 4.8 V allowing the SKY66423-11 to be used in battery powered applications over a wide spectrum of the battery discharge curve. 16 15 14 13 The SKY66423-11 is packaged in a 16-pin, 3.0 x 3.0 x 0.75 mm Multi-Chip Module (MCM) package. 1 12 TX GND A functional block diagram of the SKY66423-11 is provided in Figure 1. Figure 2 shows the pinout for the SKY66423-11. Table 1 2 11 RX TX IN lists the pin assignments and signal descriptions. GND TX ALT 3 10 GND 4 9 CSD ANT 5 6 78 204566-002 Figure 2. SKY66423-11 Pinout (Top View) Skyworks Solutions, Inc. Phone 781 376-3000 Fax 781 376-3100 sales skyworksinc.com www.skyworksinc.com 204566H Skyworks Proprietary Information Products and Product Information are Subject to Change Without Notice May 17, 2018 1 VCC1 CPS VCC0 CTX N/C LNA IN PA OUT RX FLT PA OUT TX IN CPS CTX CSDDATA SHEET SKY66423-11: 860 TO 930 MHz RF FRONT-END MODULE Table 1. SKY66423-11 Signal Descriptions Pin Name Description Pin Name Description 1 TX Transmit mode RF input 10 GND Connect to PCB ground 2 RX Receive mode RF output 11 TX IN TX input signal to antenna (from OMN) 3 TX ALT Transmit mode RF input (alternate pin) 12 GND Connect to PCB ground 4 CSD Shutdown control input 13 PA OUT PA output and positive power supply 5 CPS Bypass mode select input 14 N/C Not connected internally to the device 6 CTX Transmit mode select input 15 VCC0 Positive power supply 7 LNA IN LNA input (from RX filter) 16 VCC1 Positive power supply Exposed die paddle electrical and thermal 8 RX FLT RX signal from antenna (to RX filter) Paddle GND ground. Connect to PCB ground 9 ANT Connect to 50 antenna Electrical and Mechanical Specifications Table 2 provides the absolute maximum ratings, and Table 3 The state of the SKY66423-11 is determined by the control logic shows the recommended operating conditions. Electrical shown in Tables 7 and 8. specifications are provided in Tables 4 through 6. 1 Table 2. SKY66423-11 Absolute Maximum Ratings Parameter Symbol Minimum Maximum Units Supply voltage on VCC0 (no RF) VCC0 -0.3 5.5 V Supply voltage on VCC1 and PA OUT (no RF) VCC -0.3 5.5 V Operating temperature TA -40 85 C Storage temperature TSTG -40 125 C Tx input power at TX port PIN TX MAX +10 dBm TX input power at TX port (bypass mode) PIN TX BYP MAX +20 dBm Rx input power at ANT port PIN RX MAX +10 dBm Electrostatic discharge: ESD Human Body Model (HBM), Class 1C 1000 V 1 Exposure to maximum rating conditions for extended periods may reduce device reliability. There is no damage to device with only one parameter set at the limit and all other parameters set at or below their nominal value. Exceeding any of the limits listed here may result in permanent damage to the device. ESD HANDLING: Although this device is designed to be as robust as possible, electrostatic discharge (ESD) can damage this device. This device must be protected at all times from ESD when handling or transporting. Static charges may easily produce potentials of several kilovolts on the human body or equipment, which can discharge without detection. Industry-standard ESD handling precautions should be used at all times. Skyworks Solutions, Inc. Phone 781 376-3000 Fax 781 376-3100 sales skyworksinc.com www.skyworksinc.com 2 May 17, 2018 Skyworks Proprietary Information Products and Product Information are Subject to Change Without Notice 204566H