110W Triple Output CINT3110 Family Industrial Grade FEATURES AND BENEFITS Industrial 2 X 4 X 1.3 Package Approved to EN/CSA/IEC/UL62368-1 Suitable For 1U Applications Power Fail Signal 110W W/air, 80W Convection Cooled Remote Sense 3 Year Warranty Universal Input 90VAC264VAC Efficiency 87% Typical RoHs Compliant MODEL SELECTION Output Current** Ripple & Total OVP Model Number Volts* w/200LFM air Convection Noise*** Regulation Threshold V1 5V 14.0A 10.0A 1.0% pk-pk 2% 7.5V max 115%135% CINT3110A0508K01 V2 12V 6.0A 4.5A 1.0% pk-pk 3% 115%135% V3 -12V 1.0A 1.0A 2.0% pk-pk 10% V1 5V 14.0A 10.0A 1.0% pk-pk 2% 7.5V max 115%135% CINT3110A1708K01 V2 15V 4.5A 3.5A 1.0% pk-pk 3% 115%135% V3 -15V 1.0A 1.0A 2.0% pk-pk 10% V1 5V 12.0A 8.0A 1.0% pk-pk 2% 7.5V max 115%135% CINT3110A1908K01 V2 24V 4.0A 3.0A 1.0% pk-pk 3% 115%135% V3 -24V 1.0A 1.0A 2.0% pk-pk 10% Notes: 1. * 5V output is adjustable with +/-5% range 2. ** Total convection power is 80 watts. 3. *** Measured with noise probe directly across output terminals, and load terminated with 0.1F ceramic and 10F low ESR capacitors. Ripple & Noise of V2 at no load is 2% maximum. CINT3110 Datasheet v1220 Copyright 20 20 SL Power Electronics Corp. All rights reserved. Page 1110W Triple Output CINT3110 Family Industrial Grade INPUT OUTPUT Input Voltage and 100VAC240VAC, 10%, 47Hz63Hz, 1 Output Voltage See models chart Frequency 120VDC370VDC 110W continuous with 200 lfm airflow, 80W Input Current 115VAC: 1.5A, 230VAC: 0.75A Output Power convection cooled See chart for specific voltage model ratings Inrush Current 264VAC, cold start: will not exceed 45A Less than 2 sec. 115VAC (inversely proportional Turn On Time Input Fuses F1, F2: 2.5A, 250VAC fuses provided on all models to input voltage and thermistor temperature) Earth Leakage Current <290A 264VAC, 60Hz, NC Hold-up Time 16mS typical at 110W, 120VAC input Efficiency 87% typical at 230VAC Adjustment 5% from nominal on 5V output Output Voltage Ripple and Noise See models chart SAFETY See models chart Total Regulation Safety Standards EN/CSA/IEC/UL62368-1 Switching Frequency PFC: 75kHz typical 500S typ. for return to within 0.5% of nominal, 50% Transient Response load step. i/t <0.2A/S, Max Volt Deviation = 3% ISOLATION Not required Minimum Load Input-Output: 4000VAC Isolation Safety Rating Input-Ground: 1800VAC Output-Ground: 500VAC PROTECTION Overvoltage Protection See models chart for trip range RELIABILITY Provided - no damage will occur if the output is Short Circuit Protection shorted MTBF 2,45,000 hours, 25C Ambient, 110VAC input 150%300% above rating for V2 & V3, Overload Protection 110%200% for V1. Hiccup Mode ENVIRONMENT EMI/EMC COMPLIANCE Operating Temperature -10C to +70C Relative Humidity 5% to 95%, non-condensing EN55011/22 Class B, FCC Part 15, Subpart B, Conducted Emissions Class B Weight 200 grams EN55011/22 Class A FCC Part 15, Subpart A, Dimensions 2.0 x 4.0 x 1.3 Radiated Emissions Class A Derate output power linearly above 50C to 50% Temperature Derating EN61000-4-2, Criteria A, 6kV Contact at 70C Static Discharge Immunity Discharge, 8kV air discharge Operating: -500 feet to 10,000 feet Altitude Radiated RF Immunity EN61000-4-3, 3V/m. Criteria A Non-operating: -500 feet to 40,000 feet EFT/Burst Immunity EN61000-4-4, 2kV/5kHz, Criteria A Storage Temperature -40C to +85C Operating: 0.003g/Hz, 1.5 grams overall, 3 axes, EN61000-4-5, 1kV differential, 2kV Line Surge Immunity common-mode, Criteria A 10 min/axis Vibration Non-Operating: 0.026g/Hz, 5.0 grams overall, Conducted RF Immunity EN61000-4-6, 3Vrms, Criteria A 3 axes, 1 hour/axis Power Frequency Magnetic Operating: Half-sine, 20gpk, 10mS, 3 axes, EN61000-4-8, 3A/m, Criteria A Field Immunity 6 shocks total Shock EN61000-4-11, 0% Vin, 0.5 cycle 40% Vin, 5 Non-Operating: Half-sine, 40 gpk, 10mS, 3 axes, Voltage Dip Immunity cycles 70% Vin, 25 cycles Criteria A 6 shocks total Line Harmonic Emissions EN61000-3-2, Class A, B, C, & D Flicker Test EN61000-3-3, Complies (dmax<6%) CINT3110 Datasheet v1220 Copyright 20 20 SL Power Electronics Corp. All rights reserved. Page 2