DCx40 DC/DC Converters FEATURES 40 W dc/dc converter Same size as ac input version Drop-in replacement for GLC40 series Two input ranges: 24 V and 48 V Two-year warrranty Full off-line isolation Single and multiple output versions available marked to LVD SPECIFICATIONS: Input DCD models: 24 Vdc, 18-32 Vdc DCG models: 48 Vdc, 36-72 Vdc. power dissipation in some outputs. Consult factory for application Hold-up Time assistance. 6mSec minimum from loss of dc input at full load, nominal line. Efficiency Output Power 68% minimum at full rated load, nominal input voltage, depending Normal continuous output power is 40 W (45 W Pk) for 60 sec. upon model and load distribution. Single-output models = 72% to 80% depending upon model. Output Regulation Regulation for multiple-output models measured by 40% load Overshoot Less than 3% at turn-on under nominal conditions, inversely changeFrom 60% rated load with all other outputs at 60% full rated load and a line voltage change from low line to high line. proportional to input voltage and temperature. Less than 2% Initial set tolerance is measured with all outputs at 60% of full overshoot at turn-off under all conditions. rated load. Output voltage V1 requires 20% load for proper Turn-on Time regulation of multiple-output models. Regulation for single-output Less than 1 sec. At nominal line, 25C (inversely proportional to models measured by changing load from 5% load to 50% load or input voltage and thermistor temperature). 50% load to full load in either direction. Input Protection Internal fuse provided on all units. Inadvertent reverse voltage Remote Sense application will blow fuse without risk of fire or shock hazard. Standard on single-output versions. Capable of compensating for Otherwise, internal fuse is designed to protect against cata- 0.25 V total of cabling losses in the output voltage. strophic circuit failures. Fuse does not blow on overload or short Overload Protection circuit. Fully protected against short circuit and output overload. Short Inrush Current circuit protection is cycling type power limit on outputs 1 and 2 Inrush is limited by internal thermistors to 22 A pk 24 Vdc and foldback type on output 3. Factory set to begin power limiting at 44 A pk 48 Vdc. approximately 55 W. Temperature Coefficient No Load Turn-on/Standby 0.03%/C typical on all outputs. No degradation of reliability will occur however, regulation may be Environmental affected. Designed for 0 to 50C operation at full rated output power derate Output Noise and Ripple output current and total output power by 2.5% per C above 50C. 0.5% RMS, 1.5% Pk-Pk, 20 MHz bandwidth, differential mode. See Environmental and Packing Specification on next page. Measured with scope probe directly across output terminals of Storage the power supply with load terminated with 0.1 f capacitor. Transient Response -40 to +85 C. Main output 500 sec typical response time for return to within EMI Compliance 0.5% of final value for a 50% load step within the regulation limits All models include built-in EMI filtering to meet or exceed the of minimum and maximum load, i/ t<0.2/sec. Maximum emissions requirements of FCC Class B. CISPR 22-Class B. voltage deviation is 3.5%. Typical margins >3dB at all frequencies and line/load conditions. Overvoltage Protection Safety Built in on V1 with firing point set per output ratings table. OVP All DCx models are approved to UL 1950 (with no D4 deviations), firing reduces outputs 1 and 2 to less than 50% of nominal CSA22.2 No. 234 Level 3, IEC950, EN60950. voltage in 50 msec. Voltage Adjustment Factory set on standard units. However, optional potentiometer adjusts voltage from 4.7 V to OVP point (6.2 V nominal) on the +5 V output. Note: output 1 must not be more than 1% below nominal to achieve full output voltage range on output 2. Output regulation limits in some models may be exceeded when the main output is adjusted beyond +/- 1% of nominal voltage. See output ratings chart for additional notes and conditions. High voltage settings may degrade the reliability of the unit due to excessive Condor D.C. Power Supplies, Inc., 2311 Statham Parkway, Oxnard, CA 93033 800-235-5929 805-486-4565 FAX 805-487-8911 www.condorpower.com 104DCx40 DC/DC Converters Model (B) Output No. Output Minimum Load Current Total Regulation OVP Ripple and Noise Notes D1Cx40A +A5.1V0A.4 4%2V6%.2 0.6 1 2V+A12 0A.2 2%6%1A 3V-A12 0A0%.45%1 D1Cx40B +A5.1V0A.4 4%2V6%.2 0.6 1 2V+A15 0A.2 2%6%1A 3V-A15 0A0%.45%1 D1Cx40D +A5.1V0A.4 4%2V6%.2 0.6 1 2V+A24 0A.1 1%6%1A 3V-A12 0A0%.45%1 D1Cx40-5 7%.8A2V6%.2 0.6 1 D1Cx40-12 3%.3A2V1%4 1.1 1 D1Cx40-15 2%.7A2V1%8.5 1.5 1 D1Cx40-24 1%.7A2V2%8 2.5 1 D1Cx40-28 1%.4A2V3%4 2.8 1 A. To maintain these regulation conditions, the 5.1 V current must be at least 20% of V2 and not greater than five times the V2 current, and requires +5.1 V to be adjusted within 1%, with at least a 0.4 A load. B. Replace x with D for 24 Vdc input or G for 48 Vdc input. DCx40 MECHANICAL SPECIFICATIONS Dimensions: Inches Millimeters Environmental Operating Non-operating Specification o o T0emperature (A) 0 to 5C5-40 to +8 C A. Units should be allowed to warm up/operate under non-condensing conditions before application of HHumidity (A)0Hto 95% R 0 to 95% R power. Derated output current and toal output power by 2.5% per C above 50C. Sghock (B) 20 40 g pk pk B. Random vibration10 to 2000Hz, 6dB/octave roll-off from 350 to 2000Hz, 3 orthogonal axes. Tested for 10 min./axis operating and 1 hr./axis non-operating. Atltitude-t500 to 10,000 f -500 to 40,000 f 2 2 Vgibration (C) 1.5 , 0.003 g/gHz 5 , 0.026 g /Hz C. Shock testinghalf-sinusoidal, 10 3 ms duration, direction, 3 orthogonal axes, total 6 shocks. rms rms Condor D.C. Power Supplies, Inc., 2311 Statham Parkway, Oxnard, CA 93033 800-235-5929 805-486-4565 FAX 805-487-8911 www.condorpower.com 105