130W Quad Output GB130Q Medical/Test & Measurement/Industrial Grade FEATURES AND BENEFITS Medical 3 x 5 x 1.5 Package Meets Class B Radiated & Conducted EMI 130W w/air, 100W Convection Cooled 5V 1A Standby Output Test & Measurement Universal Input 90-264VAC Remote Inhibit Efficiency 87% Typical >7 Year E-cap Life Industrial Approved to CSA/EN/IEC/UL62368, IEC61326-1 3 Year Warranty Approved to CSA/EN/IEC/UL60601-1, 3rd Edition RoHS Compliant MODEL SELECTION Output Current Maximum Output Power Model Ripple & Total 1 Volts 200LFM air Convection OVP Threshold 2,3 2 3 Number Noise Regulation 200LFM air Convection Min Max Min Max Peak V1 5V 1A 16A 1A 12A 16A 1.0% pk-pk 3% 7.5V max. V2 12V 0A 4A 0A 3A 5A 1.0% pk-pk 3% 120%-140% GB130QA 130W 100W V3 -12V 0A 1.2A 0A 1A 1.2A 1.0% pk-pk 3% 120%-140% V4 12V 0A 1.2A 0A 1A 1.2A 1.0% pk-pk 3% 120%-140% V1 5V 1A 16A 1A 12A 16A 1.0% pk-pk 3% 7.5V max. V2 12V 0A 4A 0A 3A 5A 1.0% pk-pk 3% 120%-140% 4 GB130QC 130W 100W V3 -15V 0A 1.2A 0A 1A 1.2A 1.0% pk-pk 3% 120%-140% V4 15V 0A 1.2A 0A 1A 1.2A 1.0% pk-pk 3% 120%-140% V1 5V 1A 16A 1A 12A 16A 1.0% pk-pk 3% 7.5V max. V2 24V 0A 3A 0A 2A 5A 1.0% pk-pk 3% 120%-140% 4 GB130QD 130W 100W V3 -12V 0A 1A 0A 1.2A 1.2A 1.0% pk-pk 3% 120%-140% V4 12V 0A 1A 0A 1.2A 1.2A 1.0% pk-pk 3% 120%-140% V1 5V 1A 16A 1A 12A 16A 1.0% pk-pk 3% 7.5V max. V2 24V 0A 3A 0A 2A 5A 1.0% pk-pk 3% 120%-140% 4 GB130QE 130W 100W V3 -15V 0A 1.2A 0A 1A 1.2A 1.0% pk-pk 3% 120%-140% V4 15V 0A 1.2A 0A 1A 16A 1.0% pk-pk 3% 120%-140% V1 5V 1A 16A 1A 10A 16A 1.0% pk-pk 3% 7.5V max. V2 24V 0.5A 5A 0.5A 4A 5A 1.7% pk-pk +10%/-5% 120%-140% GB130QP 130W 100W V3 -12V 0A 1.2A 0A 1A 1.2A 1.0% pk-pk 3% 120%-140% V4 12V 0A 2A 0A 2A 1.2A 1.0% pk-pk 3% 120%-140% Notes: 1. 5V output is adjustable with +/-10% rangeOther output voltages available, consult factory. 2. Measured with noise probe directly across output terminals, and load terminated with 0.1F ceramic and 47F low ESR capacitors. Ripple & Noise of V2 at no load is 2% maximum. All specifications are typical at 230Vac, full load, at 25C ambient unless noted. 3. Total Regulation is defined as the maximum deviation from the nominal voltage for all steady state conditions of initial voltage setting, input line voltage, and output load. 4. Contact factory for availability of specific models. GB130Q Datasheet v0319 Copyright 2019 SL Power Electronics Corp. - All rights Page 1130W Quad Output GB130Q Medical/Test & Measurement/Industrial Grade INPUT OUTPUT 130W continuous with 200 lfm airflow, 100W 100-240Vac, -20, +10%, 47-63Hz, 1 AC Input convection cooled See chart for specific voltage Output Power 115Vac: TBDA, 230Vac: TBDA Input Current model ratings. 264Vac, cold start: will not exceed 75A See models chart Inrush Current Ripple and Noise F1, F2: TBDA, 250Vac fuses provided on all models Input Fuses See models chart Output Voltage +/-10% from nominal on 5V output Leakage Current Voltage Adjustability <290A 264Vac, 60Hz, NC Earth: <100A 264Vac, 60Hz, NC, <500uA, SFC Less than 2 sec. 115Vac (inversely proportional to Patient: Turn On Time input voltage and thermistor temperature) 87% typical at 230Vac Efficiency 16mS typical at 110W, 120Vac input Hold-up Time Switching Frequency PFC: 0.9 typical ENVIRONMENT 500S typ. for return to within 0.5% of nominal, 50% Operating: 0.003g/Hz, 1.5grms overall, 3 axes, 10 Transient Response load step. i/t <0.2A/S. min/axis Max Volt Deviation = 3% Vibration Non-Operating: 0.026g/Hz, 5.0grms overall, 3 axes, 1 hr/axis SAFETY W: 4.0 x L: 6.0 x H: 1.5 Dimensions TBDg Weight IEC/UL61326-1 IEC/UL/CSA62368 Less than 2 sec. 115Vac (inversely proportional to Safety Standards Turn On Time DEMKO EN62368 input voltage and thermistor temperature) 16mS typical at 110W, 120Vac input Hold-up Time RELIABILITY -20C to +70C Operating Temperature 250,000 hours, 25C Ambient, 110Vac input MTBF Derate output power linearly above 50C to 50% at Temperature Derating >7 Years in use condition of 40C ambient, at 12h/ 70C day, 261 days/year. Additional information on other E-Cap Life -40C to +85C Storage Temperature use profiles available on request. Minimum Load See models chart Operating: -500 to 15,000 ft. Altitude Non-operating: -500 to 40,000 ft. Total Regulation See models chart Relative Humidity 5% to 95%, non-condensing PROTECTION Notes: 1. Specifications are for convection rating at factory settings at 115 Vac input, 25C ambient Parameter Conditions/Description Min Nom Max Units unless otherwise stated. TBD A/250V internal fuse Not user acces- 2. For DC input an external DC safety rated fuse must be used. Input Fuse in both line & neutral sible 4KV(CM) and 2KV(DM) KV Input Transient AUXILIARY SIGNALS 4 surge (CM) Protection Provided - no damage During normal operation, stays HIGH. Signal goes Short Circuit will occur if the output is Hiccup Mode LOW with at least 6mS warning before loss of DC AC Power Fail Protection shorted. output from AC failure. 150%-300% above rating Via switch closure Remote Inhibit for V2, V3, & V4 110%- Hiccup Mode Overload Protection 200% for V1. During normal operation, this signal is logic HIGH. Signal will go LOW for output less than 90% (typical) Latching Type, recycle AC See models chart for trip Overvoltage DC OK of nominal. Green LED will light on PCB top side input to reset ranges Protection during normal operation. Operating: Half-sine, 5V 1.0A output, always present when AC input is 20gpk, 10ms, 3 axes, 6 5V Standby Output applied to the unit. shocks total Shock Non-Operating: Half-sine, 40 gpk, 10 ms, 3 axes, 6 shocks total GB130Q Datasheet v0319 Copyright 2019 SL Power Electronics Corp. - All rights Page 2