130W Quad Output GB130Q Family Medical & Industrial Grade FEATURES AND BENEFITS Medical 3 x 5 x 1.35 Package Meets Class B Radiated & Conducted EMI 130W w/air, 100W Convection Cooled 5V 1A Standby Output, Remote Inhibit Industrial Universal Input 90-264VAC No Minimum Load Required >7 Year E-cap Life Efficiency 87% Typical Approved to CSA/EN/IEC/UL62368-1 3 Year Warranty Covered Versions Available Approved to CSA/EN/IEC/UL60601-1, 3rd Ed. +Am1 RoHS Compliant MODEL SELECTION Output Current Maximum Output Power Model Ripple & Total 1 Volts OVP Threshold 2,3 200LFM air Convection 2 3 Number Noise Regulation 200LFM air Convection Min Max Min Max Peak V1 5V 0A 16A 0A 12A 16A 1.0% pk-pk 3% 7.5V max. V2 12V 0A 4A 0A 3A 5A 1.0% pk-pk 3% 120%-140% GB130QA 130W 100W V3 -12V 0A 1.2A 0A 1A 1.2A 1.0% pk-pk 3% 120%-140% V4 12V 0A 1.2A 0A 1A 1.2A 1.0% pk-pk 3% 120%-140% V1 5V 0A 16A 0A 12A 16A 1.0% pk-pk 3% 7.5V max. V2 12V 0A 4A 0A 3A 5A 1.0% pk-pk 3% 120%-140% 4 GB130QC 130W 100W V3 -15V 0A 1.2A 0A 1A 1.2A 1.0% pk-pk 3% 120%-140% V4 15V 0A 1.2A 0A 1A 1.2A 1.0% pk-pk 3% 120%-140% V1 5V 0A 16A 0A 12A 16A 1.0% pk-pk 3% 7.5V max. V2 24V 0A 3A 0A 2A 5A 1.0% pk-pk 3% 120%-140% 4 GB130QD 130W 100W V3 -12V 0A 1A 0A 1.2A 1.2A 1.0% pk-pk 3% 120%-140% V4 12V 0A 1A 0A 1.2A 1.2A 1.0% pk-pk 3% 120%-140% V1 5V 0A 16A 0A 12A 16A 1.0% pk-pk 3% 7.5V max. V2 24V 0A 3A 0A 2A 5A 1.0% pk-pk 3% 120%-140% 4 GB130QE 130W 100W V3 -15V 0A 1.2A 0A 1A 1.2A 1.0% pk-pk 3% 120%-140% V4 15V 0A 1.2A 0A 1A 1.2A 1.0% pk-pk 3% 120%-140% V1 5V 0A 16A 0A 10A 16A 1.0% pk-pk 3% 7.5V max. V2 24V 0A 5A 0A 4A 5A 1.7% pk-pk +10%/-5% 120%-140% GB130QP 130W 100W V3 -12V 0A 1.2A 0A 1A 1.2A 1.0% pk-pk 3% 120%-140% V4 12V 0A 2A 0A 2A 2A 1.0% pk-pk 3% 120%-140% Notes: 1. 5V output is adjustable with +/-10% range. Other output voltages available, consult factory. 2. Measured with noise probe directly across output terminals, and load terminated with 0.1F ceramic and 47F low ESR capacitors. Ripple & Noise of V2 at no load is 2% maximum. All specifications are typical at 230Vac, full load, at 25C ambient unless noted. 3. Total Regulation is defined as the maximum deviation from the nominal voltage for all steady state conditions of initial voltage setting, input line voltage, and output load. 4. Contact factory for availability of specific models. 5. For models with optional cover/chassis, add- suffix to above model numbers. Output power derates to 104W with airflow, 75W convection cooled. Page 1 GB130Q Datasheet v0520 Copyright 2020 SL Power Electronics Corp. All rights reserved.130W Quad Output GB130Q Family Medical & Industrial Grade INPUT OUTPUT AC Input Open Frame: 130W continuous with 200 lfm 100-240Vac, -20, +10%, 47-63Hz, 1 Output Power airflow, 100W convection cooled. Covered models: Input Current 115Vac: 2.0A, 230Vac: 1.5A 104W with airflow, 75W convection cooled. Inrush Current 264Vac, cold start: will not exceed 75A Ripple and Noise See models chart Input Fuses F1, F2: 3.15A, 250Vac fuses provided on all models Output Voltage See models chart Leakage Current Voltage Adjustability <290A 264Vac, 60Hz, NC +/-10% from nominal on 5V output Earth: <100A 264Vac, 60Hz, NC, <500uA, SFC Less than 2 sec. 115Vac (inversely proportional Patient: Turn On Time to input voltage and thermistor temperature) Efficiency 87% typical at 230Vac Hold-up Time 16mS typical at 110W, 120Vac input ENVIRONMENT Switching Frequency PFC: 0.9 typical Operating: 0.003g/Hz, 1.5grms overall, 3 axes, 10 500S typ. for return to within 0.5% of nominal, 50% Transient Response min/axis load step. i/t <0.2A/S. Vibration Non-Operating: 0.026g/Hz, 5.0grms overall, 3 axes, Max Volt Deviation = 3% 1 hr/axis Dimensions W: 3.0 x L: 5.0 x H: 1.35 SAFETY Weight 300g CSA/IEC/EN/UL62368-1 Less than 2 sec. 115Vac (inversely proportional Safety Standards Turn On Time CSA/IEC/EN/UL60601-1, 3rd Ed. + Am1 to input voltage and thermistor temperature) Hold-up Time 16mS typical at 110W, 120Vac input RELIABILITY Operating Temperature -20C to +70C MTBF 250,000 hours, 25C Ambient, 110Vac input Derate output power linearly above 50C to 50% at Temperature Derating 70C >7 Years in use condition of 40C ambient, at 12h/ E-Cap Life day, 261 days/year. Additional information on Storage Temperature -40C to +85C other use prvailable on request. Minimum Load Operating: -500 to 15,000 ft. See models chart Altitude Non-operating: -500 to 40,000 ft. Total Regulation See models chart Relative Humidity 5% to 95%, non-condensing PROTECTION Notes: 1. Spee for convection rating at factory settings at 115 Vac input, 25C ambient Min Nom Max Units Parameter Conditions/Description unless otherwise stated. 2. For DC input an external DC safety rated fuse must be used. 3.15A/250V internal fuse in Not user Input Fuse both line & neutral accessible Input Transient KV AUXILIARY SIGNALS 4KV(CM) and 2KV(DM) surge 4 Protection (CM) Short Circuit Provided - no damage will During normal operation, stays HIGH. Signal goes Hiccup Mode Protection occur if the output is shorted. AC Power Fail LOW with at least 6mS warning before loss of DC output from AC failure. 150%-300% above rating for Overload V2, V3, & V4 110%-200% Hiccup Mode Protection Remote Inhibit Via switch closure for V1. During normal operation, this signal is logic HIGH. Overvoltage Latching Type, recycle AC See models chart for trip Signal will go LOW for output less than 90% (typical) Protection input to reset ranges DC OK of nominal. Green LED will light on PCB top side Operating: Half-sine, 20gpk, during normal operation. 10ms, 3 axes, 6 shocks total 5V 1.0A output, always present when AC input is Shock Non-Operating: Half-sine, 40 5V Standby Output applied to the unit. gpk, 10 ms, 3 axes, 6 shocks total Page 2 GB130Q Datasheet v0520 Copyright 2020 SL Power Electronics Corp. All rights reserved.