GLC110 Commercial/GLM110 Medical 110 Watt Global Performance Switchers GLOBAL PERFORMANCE SWITCHERS FEATURES: Cost-effective power source Single- and dual-output units Low height (1.30) 2-year warranty Power fail signal standard Commercial Approved to UL60950-1, EN60950-1, CSA22.2 No. 950-95 3rd Ed. Medical Approved to UL2601-1, EN60601-1, CSA-C22.2 No. 601.1 Complies with EN61000-3-2 Class A RoHS Compliant Model Available (G suffix) SPECIFICATIONS Ac Input 90-264 Vac, 47-63 Hz single phase. Transient Response Input Current Maximum input current at 90 Vac, 60 Hz with full rated output load not to Main Output: 500 s typical response time for return to within 0.5% of final value exceed 2.9 A. for a 50% load step change, i/t<0.2 A/s. Maximum voltage deviation is 3.5%. Startup/shutdown overshoot less than 3%. Turn-On Time less than 1 second at 120 Hold-up Time Vac, 25. 20 ms minimum from loss of ac input at full load, nominal line (120 Vac). Overvoltage Protection Output Power Built in on main output. Normal continuous output power is 75 W for unrestricted natural convection, Efficiency or 110 W with 26 cfm air flow. 72-85% depending on model. Output Regulation Load regulation on dual output models is measured by 40% load change Input Protection from 60% rated load and input voltage change from minimum to maximum Internal ac fuse provided on all units. Designed to blow only if a catastrophic ratings. failure occurs in the unit. Output 1 requires 1A minimum load for proper regulation of other outputs. Inrush Current Initial set tolerance is measured with all outputs at 60% of full rated load. Inrush limited by internal thermistors. Inrush at 240 Vac, averaged over the first ac half-cycle under cold start conditions will not exceed 37 A. Load regulation for single-output models measured by changing load from 5% to 50% load or 50% to full load in either direction. Temperature Coefficient Voltage Adjustment 0.03%/C typical on all outputs. Output 1 adjustment is 5%. Note: output 1 must not be more than 1% EMI/EMC Compliance below nominal to achieve full output regulation on output 2. High voltage All models include built-in EMI filtering to meet the following emissions require - settings may degrade the reliability of the unit due to excessive power ments: dissipation in some outputs. EMI SPECIFICATIONS COMPLIANCE LEVEL Overload Protection Conducted Emissions GLC110 EN55022 Class B FCC Class B Fully protected against short circuit and output overload. Short circuit protec- Conducted Emissions GLM110 EN55011 Class B: FCC Class B tion is cycling type power limit. Factory set to begin power limiting at 120 W. Static Discharge EN61000-4-2, 6 kV contact, 8 kV air RF Field Susceptibility EN61000-4-3, 3 V/meter Output Noise Fast Transients/Bursts EN61000-4-4, 2 kV, 5 kHz 0.5% rms, 1% pk-pk, 20 MHz bandwidth, differential mode. Measured with noise probe directly across output terminals of the power supply. Surge Susceptibility EN61000-4-5, 1 kV diff., 2 kV com. Line Frequency Harmonics EN61000-3-2 Class A POWER FAIL Power fail signal is TTL or CMOS compatible (output goes low <0.5 V) 5 ms Commercial Safety before output voltage drops more than 4% below nominal voltage upon All GLC models are approved to UL60950-1, CSA22.2 No. 950-95 3rd Ed, and loss of AC power. The signal is factory set to trip on 84 to 94 Vac brown-out EN60950-1. depending upon incoming line impedance and distortion. Other settings are Medical Safety available to the user through adjustment of built in potentiometer (consult All GLM models are approved to UL2601-1, CSA-C22.2 No. 601.1, EN60601-1. factory for assistance). Output will stay low for 20 ms minimum. O All specifications are typical at nominal input, full load at 25 C unless otherwise statedCommercial Medical RoHS Output Output Output Output Forced Air Output Peak Noise P-P OVP Total Regu- Model Model Suffix* No. Minumum Normal (A) (B) lation ( C ) GLC110-212 GLM110-212 G 1 +12 V 1 A 6.3 A 9.1 A 9.5 A 100 mV 15.6 1.1 V 2% 2 -12 V 0 A 2.5 A 3 A 4 A 120 mV 2% GLC110-215 GLM110-215 G 1 +15 V 1 A 5 A 7.3 A 7.7 A 120 mV 18.5 1.5 V 2% 2 -15 V 0 A 2.5 A 3 A 4 A 150 mV 2% GLC110-524 GLM110-524 G 1 +24 V 1 A 3.2 A 4.6 A 4.75 A 200 mV 28 2.5 V 2% 2 +5 V 0 A 1.5 A 2 A 2.5 A 50 mV 6.2 0.6 V 2% GLC110-12 GLM110-12 G 1 12 V 0 A 6.3 A 9.1 A 9.5 A 120 mV 15.6 1.1 V 2% GLC110-15 GLM110-15 G 1 15 V 0 A 5 A 7.3 A 7.7 A 150 mV 18.5 1.5 V 2% GLC110-24 GLM110-24 G 1 24 V 0 A 3.2 A 4.6 A 5 A 240 mV 28 2.5 V 2% * Add G suffix to part number for RoHS compliant model. Contact factory for availability. A. Rating with unrestricted convection cooling. Total power not to exceed 75 W no output can exceed rated current. B. Rating with 26 cfm forced air cooling. Total power not to exceed 110 W. C. To maintain regulation V1 current must be at least 1/5 of V2. V1 must not be adjusted more than 1% below nominal and have at least 10% of rated load. GLC110/GLM110 MECHANICAL SPECIFICATIONS ENVIRONMENTAL SPECIFICATIONS OPERATING NON-OPERATING A. Units should be allowed to warm up/operate under non-condensing conditions before application of power. Derated output current and toal Temperature (A) 0 to 50 -40 to +85C output power by 2.5% per C above 50C. Humidity (A) 0 to 95% RH 0 to 95% RH B. Random vibration10 to 2000Hz, 6dB/octave roll-off from 350 to Shock (C) 20 g 40 g 2000Hz, 3 orthogonal axes. Tested for 10 min./axis operating and 1 pk pk hr./axis non-operating. Altitude -500 to 10,000 ft -500 to 40,000 ft C. Shock testinghalf-sinusoidal, 10 3 ms duration, direction, 3 2 2 Vibration (B) 1.5 g 0.003 g /Hz 5 g 0.026 g /Hz rms rms orthogonal axes, total 6 shocks. SL Power Electronics Corp, 6050 King Drive, Bldg. A, Ventura, CA 93003, USA. Phone:(805) 486 4565 Fax:(805) 487 8911 Email: info slpower.com Rev. 02/11/10. Data Sheet 2010 SL Power Electronics Corp. The information and specifications contained in this data sheet are believed to be correct at time of publication. However, SL Power accepts no responsibility for consequences arising from reproduction errors or inaccuracies. Specifications are subject to change without notice.