GLC65 Commercial/GLM65 Medical
65 Watt Single Output Global Performance Switchers
GLOBAL PERFORMANCE SWITCHERS
FEATURES:
4.1 W/in3
Compact (3.0 x 5.0 x 1.06)
Ultra-high efficiency (up to 94%) using patented
technology
Meets harmonic requirements of IEC1000-3-2, Class A
Conducted EMI exceeds FCC Class B and CISPR 22
Class B (Commercial models) and CISPR 11 Class B
(Medical models)
2-year warranty
Exempt from line harmonics standard EN61000-3-2
Commercial Approved to UL1950, IEC950, EN60950,
CSA22.2 No. 950
Medical Approved to UL2601, EN60601, CSA22.2
No. 601.1
Multiple output versions also available
RoHS models available (G suffix)
marked to LVD
SPECIFICATIONS
Ac Input
Inrush Current
90-264 Vac, 47-63 Hz single phase.
Inrush is limited by internal thermistor. The inrush at 240 Vac, averaged over the
first ac half-cycle under cold start conditions will not exceed 37A.
Input Current
Maximum input current at minimum output voltage and output overload
EMI/EMC Compliance
will be less than 1.7 A. Meets input current harmonic requirements of
All models include built-in EMI filtering to meet the following emissions
IEC1000-3-2.
requirements:
Output Power
EMI SPECIFICATIONS COMPLIANCE LEVEL
Normal continuous output power is 65 W, 75 W peak for 60 s. The 3.3 Vdc unit
Conducted Emissions GLC65 EN55022 Class B; FCC Class B
is 36.3 W and the 5 Vdc unit is 55 W continuous.
Conducted Emissions GLM65 EN55011 Class B: FCC Class B
Hold-Up Time
Static Discharge EN61000-4-2, 6 kV contact, 8 kV air
20 ms from loss of ac input at 65 W load, from 120 Vac input.
RF Field Susceptibility EN61000-4-3, 3 V/meter
Fast Transients/Bursts EN61000-4-4, 2 kV, 5 kHz
Overload Protection
Surge Susceptibility EN61000-4-5, 1 kV diff., 2 kV com.
Fully protected against short circuit and output overload. Short circuit protec-
tion is cycling type power limit.
Commercial Leakage Current
Output Noise
Under normal conditions, leakage current is 425 A with 132 Vac @ 60 Hz input.
0.5% rms, 1% pk-pk, 20 MHz bandwidth, differential mode. Measured with
Commercial Safety
scope probe directly across output terminals of the power supply with load
All GLC models are approved to UL1950, CSA22.2 No. 950, IEC950 and EN60950.
terminated with 0.1 F capacitor.
Medical Leakage Current
Transient Response
The maximum leakage current under single-fault conditions (254 Vac @ 50 Hz) is
Main output: 500 s typical response time for return to within 0.5% of final
120 A. Under normal conditions, leakage current is 31A with 132 Vac @ 60 Hz
value for a 50% load step within the regulation limits of minimum and maxi-
input.
mum load, i/t<0.2 A/s. Maximum voltage deviation is 3.5%. Startup/shut -
down overshoot less than 3%.
Medical Safety
All GLM models are approved to UL2601, CSA22.2 No. 601, IEC601-1 and EN60601.
Voltage Adjustment
Consult factory for approval status.
Adjustable potentiometer capable of 5% change from nominal setting.
Temperature Coefficient: 0.03%C typical on all outputs.
Efficiency
82 to 94% minimum at full rated load, nominal input voltage, depending on
Remote Sense
model.
Provided as standard feature on all models. Includes open sense protection.
Minimum Load
No minimum load required.
O
All specifications are typical at nominal input, full load at 25 C unless otherwise statedCommercial Medical Output Current Total V1 Adjustment V1 OVP Setpoint Ripple
Model Model Regulation and Noise
GLC65-5 GLM65-5 5.1 V 9/11 A * 2% 5% 6.2 0.6 V 1%
GLC65-12 GLM65-12 12 V 5.5 A 2% 5% 14 1.1 V 1%
GLC65-15 GLM65-15 15 V 4.3 A 2% 5% 18.5 1.5 V 1%
GLC65-18 GLM65-18 18 V 3.6 A 2% 5% 21.7 2.0 V 1%
GLC65-20 GLM65-20 20V 3.25 A 2% 5% 24.5 2.2 V 1%
GLC65-24 GLM65-24 24 V 2.7 A 2% 5% 28 2.5 V 1%
GLC65-28 GLM65-28 28 V 2.3 A 2% 5% 34 2.8 V 1%
GLC65-48 GLM65-48 48 V 1.35 A 2% 5% 55 4.0 V 1%
Note:
* 9 A convection, 11 A with fan cooling
GLC65/GLM65 - SINGLE OUTPUT - MECHANICAL SPECIFICATIONS
1.20 30.28
ENVIRONMENTAL SPECIFICATIONS OPERATING NON-OPERATING
A. Units should be allowed to warm up/operate under non-condensing
conditions before application of power. Derate output current and total
Temperature (A) 0 to 50 -40 to +85C
output power by 2.5% per C above 50C.
Humidity (A) 0 to 95% RH 0 to 95% RH
B. Shock testinghalf-sinusoidal, 10 3 ms duration, direction, 3
Shock (B) 20 g 40 g orthogonal axes, total 6 shocks.
pk pk
Altitude -500 to 10,000 ft -500 to 40,000 ft C. Random vibration10 to 2000Hz, 6dB/octave roll-off from 350 to
2000Hz, 3 orthogonal axes. Tested for 10 min./axis operating and 1hr./
2 2
Vibration (C) 1.5 g 0.003 g /Hz 5 g 0.026 g /Hz
rms rms
axis non-operating.
SL Power Electronics Corp., 6050 King Drive, Bldg. A, Ventura, CA 93003, USA. Phone:(805) 486 4565 Fax:(805) 487 8911 www.slpower.com Rev. 01/07.