GLC65 Commercial/GLM65 Medical 65 Watt Multiple Output Global Performance Switchers MULTIPLE OUTPUT GLOBAL PERFORMANCE SWITCHERS Summary: 65 Watt Wide Range Input High Efficiency (Up to 90%) Universal input 90-264 Vac 2-year warranty Also available in single outputs Conducted EMI complies with FCC Class B and CISPR 22 Class B (Commercial models) and CISPR 11 Class B (Medical models) Exempt from line harmonics standard EN61000-3-2 Commercial Approved to UL1950, CSA-C22.2 No. 950, Medical Approved to UL2601-1, CSA 22.2 No. 601.1, and EN60601-1 Medical Approved to UL2601-1, CSA 22.2 No. 601.1, RoHS Compliant (G suffix) marked to LVD SPECIFICATIONS Ac Input Minimum Load 90-264 Vac, 47-63 Hz single phase. No minimum load required on any output. However, regulation limits may be exceeded if extreme conditions are applied. Contact factory for assistance. Output Power Total continuous output power is 60 W, 75 W peak for 60 s 10% duty cycle. Temperature Coefficient: 0.03%C typical on all outputs. Total continuous rating with 150 LFM of air is 70 W. Voltage Adjustment Input Current Units provided with one potentiometer capable of adjusting all 3 outputs a mini- Units are exempt from input current harmonic requirements of EN61000-3-2 mum of +/- 5% from nominal setting. when output power is less than 62W. Maximum input current at minimum input voltage and output overload will be less than 2.0 A. EMI / EMC Compliance: Inrush Current All models include built-in EMI filtering to meet EMC requirements of IEC601-1-2. Inrush is limited by internal thermistor. The inrush at 240 Vac, averaged over PERFORMANCE EMC STANDARD the first ac half-cycle under cold start conditions will not exceed 37 A. Input Protection Conducted Emissions GLC65 EN55022 Class B FCC Class B Internal AC fuse provided on all units. Designed to blow only if a catastrophic Conducted Emissions GLM65 EN55011 Class B FCC Class B failure occurs in the unit -- Fuse does not blow on short circuit or unsustained Static Discharge EN61000-4-2, Level 3 overload. RF Field Susceptibility EN61000-4-3, Level 3 Fast Transients/Bursts EN61000-4-4, Level 3 Holdup Time Surge Susceptibility EN61000-4-5, Level 3 Output voltage stays within regulation for 20 ms from loss of ac input at 65 W Conducted RF Susceptibility EN61000-4-6, 3V, 80% load, from 120 Vac input. Voltage Sags & Surges EN61000-4-11 Efficiency Line Frequency Harmonics EN61000-3-2 Class A (>62Wout) 80% minimum. Exempt (<62Wout) Overload Protection GLC65 Commercial - Safety Fully protected against short circuit and output overload. Short circuit SL Power Electronics Corp declares under our sole responsibility that all models protection is cycling type power limit and will automatically recover after are in conformity with the applicable requirements of EN60950 following the removal of fault. provisions of the Low Voltage Directive 73/23/EEC. All models are approved to Overvoltage Protection UL1950 (with no D3 deviations), CSA22.2 No. 950-95 3rd edition, Level 3, IEC950, Built in with firing point set. OVP firing reduces output to less than 50% of EN60950. CB certificate available. nominal voltage in less than 50 ms. Commercial Leakage Current Output Noise Less then 500 A 120 Vac. Less then 1.2 mA 240 Vac. 0.5% rms, 1% pk-pk, 20 MHz Bandwidth, differential mode. Measured with scope probe directly across output terminals of the power supply with load GLM65 Medical - Safety terminated with 1F capacitor. Approvals: All models are certified to be in compliance with the applicable require - ments of UL2601-1, CSA 22.2 No. 601.1, IEC 601-1 (1988), EN 60601-1: 1990. Transient Response Main Output - 500 s typical response time for return to within 0.5% of final Medical Leakage Current value for a 50% load step within the regulation limits of minimum and maxi- 80 A under normal conditions (132 Vac 60 Hz). Maximum under single fault mum load, i/t< 0.2 A/s. Maximum voltage deviation is 3.5%. conditions (264 Vac 60 Hz) is 180 A. O All specifications are typical at nominal input, full load at 25 C unless otherwise statedCommercial Medical Output Output Total V1 Adjustment OVP Set- Ripple/ Model Model Output No. Output Maximum (A) Maximum (B) Regulation (E) Note (C) point Noise GLC65A GLM65A 1 +5.0 V 7 A 9A 2% 5% 6.2 0.6 V 1% 2 +12 V 3 A 5 A 5% 1% 3 -12 V 2.5 A 4 A 6% 1% GLC65B GLM65B 1 +5.1 V 7 A 9 A 2% 5% 6.2 0.6 V 1% 2 +15 V 2.5 A 4 A 4% 1% 3 -15 V 2 A 3 A 5% 1% GLC65D GLM65D 1 +5.0 V 7 A 9 A 2% 5% 6.2 0.6 V 1% 2 +24 V 1.5 A 2.5 A 3% 1% 3 -12 V 2.5 A 4 A 6% 1% GLC65E GLM65E 1 +5.0 V 7 A 9 A 2% 5% 6.2 0.6 V 1% 2 +24 V 1.5 A 2.5 A 3% 1% 3 +12 V 2.5 A 4 A 6% 1% GLC65G GLM65G 1 +5.0 V 5 A 8 A 3% 5% 6.2 0.6 V 1% 2 +3.3 V 4 A 5 A 3% 1% 3 +12 V 2.5 A 4 A 6% 1% GLC65H GLM65H 1 +3.3 V 5 A 8 A 3.5% 5% 4.3 0.8 V 1% 2 +5.0 V 4 A 6 A 4.5% 1% 3 +12 V 2.5 A 3 A 6% 1% Notes: A. Continuous individual output ratings for unrestricted convection cooling. Combination of individual output loads must not exceed total power rating. B. Peak rating for 60 s 10% duty cycle or continuous rating 150 LFM forced air cooling. C. Adjustment on V1 varies all outputs simultaneously (1% on V1 1% on V2 & V3). D. Total combined current of V1 & V2 not to exceed 12 A. Combination of individual output loads must not exceed total power rating. E. Total regulation is defined as maximum deviation from the initial set point. With all other outputs at 50% load, output under test can be varied from 0 to 100% load and varied to any ac line voltage. Initial set point is 1% on V1, 2% on V2 and 3% on V3 F. Add G suffix to model number for RoHS compliant model. GLC65 MECHANICAL SPECIFICATIONS 1.20 30.28 A. Units should be allowed to warm up/operate under non-condensing con- ditions before application of power. Derate output current and total output power by 2.5% per C above 50C. For operation in a confined space, moving air may be required. Under all conditions, the cooling vs. load profile should be such that heat sinks and/or heatsink temperatures do not exceed 90 C ENVIRONMENTAL SPECIFICATIONS OPERATING NON-OPERATING for extended periods. Temperature (A) 0 TO 50C -40 to +85C B. Shock testinghalf-sinusoidal, 10 3 ms duration, direction, 3 orthogo- Humidity (A) 0 to 95% RH 0 to 95% RH nal axes, total 6 shocks. Shock (B) 20 g 40 g pk pk C. Random vibration10 to 2000Hz, 6dB/octave roll-off from 350 to 2000Hz, Altitude -500 to 10,000 ft -500 to 40,000 ft 3 orthogonal axes. Tested for 10 min./axis operating and 1 hr./axis non-op- erating. 2 2 Vibration (C) 1.5 g 0.003 g /Hz 5 g 0.026 g /Hz rms rms SL Power Electronics Corp., 6050 King Drive, Bldg. A, Ventura, CA 93003, USA. Phone:(805) 486 4565 Fax:(805) 487 8911 www.slpower.com Rev. 09/10/08. Data Sheet 2008 SL Power Electronics Corp. The information and specifications contained in this data sheet are believed to be correct at time of publication. However, SL Power accepts no responsibility for consequences arising from reproduction errors or inaccuracies. Specifications are subject to change without notice.