GLD140 Gold Performance Medical Switchers 140 Watt Multiple Output FEATURES: Compact size (4.5 x 8.5 x 1.95 ) Power factor corrected to IEC 1000-3-2 Class A Documented FMEA, WCA and EMC test results EMI compliance to CISPR11, FCC Class B, IEC601-1-2 Approved to UL2601, IEC601-1 and CSA 22.2 No. 601.1-M90 and EN60601: 1990 marked to LVD SPECIFICATIONS: Ac Input Thermal Shutdown 90-264 Vac, 47-63 Hz single phase. Provided as a standard feature. Designed to protect unit from Output Power prolonged over temperature. Continuous output power 140 W with unrestricted convection Power Fail cooling, 180 W with 150 LFM of air. TTL / CMOS compatible output goes low (<0.5 V) 10 ms before Input Current output voltage drops more than 4% below nominal voltage upon Active Power Factor Correction circuitry assures compliance loss of ac power. with IEC1000-3-2, Class A. Maximum input current at minimum Power Good input voltage and full load is 3.0 A. TTL / CMOS compatible output rises high 100 to 300 ms after V1 Efficiency reaches regulation and should assure that sufficient energy is 73 85 % at full rated load, nominal input voltage, depending on stored in the input section to provide normal power fail / model and load distribution. shutdown. Hold-up Time Inhibit 26 ms total. 16 ms minimum from loss of ac input at full load until Inhibit signal when pulled to the V1 output common will inhibit all activation of the power fail signal. Output voltages remain within output voltages. specified regulation limits for an additional 9 ms minimum after Fan Output power fail activates. An additional thermally controlled 12 Vdc, 250 mA output suitable Overload Protection for powering a dc fan is included in all models (Factory installed Fully protected against short circuit and output overload. Short cover with fan makes this output unavailable). circuit protection is cycling type power limit. EMI/EMC Compliance Output Noise All models include built-in EMI filtering to meet the following 0.5% rms, 1% pk-pk, 20 MHz Bandwidth, differential mode. requirements: Measured with noise probe directly across output terminals of EMC SPECIFICATION COMPLIANCE LEVEL the power supply. Conducted Emissions EN55011, Class B FCC Class B Transient Response Static Discharge EN61000-4-2, 6 kV contact 8 kV air 500 s typical response time for return to within 0.5% of final RF Field Susceptibility EN61000-4-3, 3V/meter value for a 45% load step from any load greater than 10% of full Fast Transients / Bursts EN61000-4-4, 2 kV, 5 kHz rated load, i/ t< 0.2 A s. Maximum voltage deviation is 3.5%. Surge Susceptibility EN61000-4-5, 1 kV diff., 2 kV com. Remote Sense Conducted RF Susceptibility EN61000-4-6, 3V Provided as a standard feature on V1 and V2. Voltage Sags & Surges EN61000-4-11 Overvoltage Protection Line Frequency Harmonics EN61000-3-2 Class A Built in on V1, 2 and 3 outputs. EMC Compliance for Gold Series Voltage Adjustment Magnetic Emissions - Emissions will not exceed the limits of the Factory set to specified voltage with user adjustable potentiom- Army curve in MIL-STD-461D, RE101 when measured at 7 cm eter on V1, 2 and 3. User can adjust V1, 2 and 3 at least 5% of from 30 Hz - 100 kHz over all nominal inputs and at full rated load. nominal output voltage. Leakage Current Output Regulation 70 A under normal conditions 120 Vac 60 Hz Regulation for all outputs is the maximum deviation from initial Single fault conditions 280 A, 264 Vac 50 Hz. set point under all line and load conditions. Initial set tolerance is SAFETY AGENCY APPROVALS: measured with all outputs at 50 % of full rated load. All models are Certified to be in compliance with the No Load Turn-On/Standby applicable requirements of UL2601-1, CSA-C22.2 No. 601.1, A minimum load of 3 A on V1 is required for proper regulation. If IEC 601-1/60601-1. not met, no degradation of reliability will occur. DESIGN VERIFICATION DOCUMENTS Temperature Coefficient The Gold series has undergone rigorous review and design 0.03% / C typical on all outputs. analysis. The following product documentation is available upon Input Protection request: 1. Failure Mode and Effects analysis (FMEA), 2. DVT Internal ac fuses provided on both lines on all units. Data, 3. EMC / Susceptibility test results. Inrush Current Inrush is limited by internal thermistors. The inrush at 240 Vac, averaged over the first ac half-cycle under cold start conditions will not exceed 37 A. Condor D.C. Power Supplies, Inc., 2311 Statham Parkway, Oxnard, CA 93033 800-235-5929 805-486-4565 FAX 805-487-8911 www.condorpower.com 58GLD140 Medical Switchers 140 Watt Multiple Output Medical Output Output Output Output Set Line OVP Ripple Model No. Voltage Current (A) Current (B) Tolerance Load Trip and Noise GLD140A 1 +5.0 V 16 A 20 A 1% 1% 6.2 0.3 V 1% 2 +12 V 6 A 8 A 1% 1% 14 0.7 V 1% 3 12 V (C) 4 A 5 A 1% 1% 14 1.2 V 1% 4 -12 V 0.75 A 1.2 A 2.2% 1% ------- 1% GLD140B 1 +5.0 V 16 A 20 A 1% 1% 6.2 0.3 V 1% 2 +12 V 6A 8 A 1% 1% 14 0.7 V 1% 3 5 V (C) 4 A 5 A 1% 1% 6.3 .5 V 1% 4 -12 V 0.75 1.2 A 2.2% 1% ------- 1% GLD140C 1 +5.0 V 16 A 20 A 1% 1% 6.2 0.3 V 1% 2 +12 V 6 A 8 A 1% 1% 14 0.7 V 1% 3 15 V (C) 4 A 5 A 1% 1% 18 1.2 V 1% 4 -15 V 0.75 A 1.2 A 2.2% 1% ------- 1% GLD140D 1 +5.0 V 16 A 20 A 1% 1% 6.2 0.3 V 1% 2 +24 V 4 A 6 A 1% 1% 27 1 V 1% 3 12 V (C) 4 A 5 A 1% 1% 14 1.2 V 1% 4 -12 V 0.75 1.2 A 2.2% 1% ------- 1% GLD140E 1 +5.0 V 16 A 20 A 1% 1% 6.2 0.3 V 1% 2 +24 V 4 A 6 A 1% 1% 27 1 V 1% 3 15 V (C) 4 A 5 A 1% 1% 18 1.2 V 1% 4 -15 V 0.75 A 1.2 A 2.2% 1% ------- 1% GLD140F 1 +5.0 V 16 A 20 A 1% 1% 6.2 0.3 V 1% 2 +15 V 5 A 7 A 1% 1% 18 1.2 V 1% 3 12V (C) 4 A 5 A 1% 1% 14 1.2 V 1% 4 -12 V 0.75 A 1.2 A 2.2% 1% ------- 1% GLD140G 1 +5.0 V 16 A 20 A 1% 1% 6.2 0.3 V 1% 2 +3.3 V 10 A 12 A 1% 1% 4.2 0.4 V 1% 3 12 V (C) 4 A 5 A 1% 1% 14 1.2 V 1% 4 -12 V 0.75 A 1.2 A 2.2% 1% ------- 1% Output Current for Individual Outputs: A. Output current for unrestricted natural convection. B. Output current with 150 LFM forced air convection or peak current rating. C. Isolated (floating) output may be referenced positive or negative. GLD140 MECHANICAL SPECIFICATIONS INPUT: JI MOLEX P.C.B. HEADER P/N 39-30-2056 PIN 1) AC GROUND PIN 2) N/C PIN 3) AC NEUTRAL PIN 4) N/C PIN 5) AC LINE MATING CONNECTOR MOLEX P/N: HOUSING 39-01-4051, CONTACT 39-00-0164 SIGNALS: J2 AMP P.C.B. HEADER P/N: 641215-6 PIN 1) +SENSE PIN 2) -SENSE PIN 3) POWER FAIL PIN 4) POWER GOOD PIN 5) COMMON PIN 6) INHIBIT MATING CONNECTOR AMP P/N: HOUSING 770602-6, CONTACT 770666-2 OUTPUT: J3 MOLEX P.C.B. HEADER P/N: 39-29-9206 PINS 1) +V3out PINS 2) -V4out PINS 3,12,13) COMMON PINS 4) +V2 SENSE PINS 5,14,15) +V2out PINS 6-8, 16) COMMON PINS 9,10,19,20) +V1out PINS 11) +V3 RTN PINS 17,18) COMMON MATING CONNECTOR MOLEX P/N: HOUSING 39-01-2200, CONTACT 39-00-0164 FAN: J5 AMP P.C.B. HEADER P/N 641215-2 PINS 1) FAN RTN PINS 2) +FAN MATING CONNECTOR AMP P/N: HOUSING 770602-2, CONTACT 770666-2 Environmental Operating Non-operating Specification o o T0emperature (A) 0 to 5C5-40 to +8 C A. Units should be allowed to warm up/operate under non-condensing conditions before application of power. HHumidity (A)0Hto 95% R 0 to 95% R B. Random vibration10 to 2000Hz, 6dB/octave roll-off from 350 to 2000Hz, 3 Sghock (B) 20 40 g orthogonal axes. Tested for 10 min./axis operating and 1 hr./axis non-operating. pk pk C. Shock testinghalf-sinusoidal, 10 3 ms duration, direction, 3 orthogonal axes, Atltitude-t500 to 10,000 f -500 to 40,000 f total 6 shocks. 2 2 Vgibration (C) 1.5 , 0.003 g/gHz 5 , 0.026 g /Hz rms rms Condor D.C. Power Supplies, Inc., 2311 Statham Parkway, Oxnard, CA 93033 800-235-5929 805-486-4565 FAX 805-487-8911 www.condorpower.com 59