GLC65 Commercial/GLM65 Medical 65 Watt Single Output Global Performance Switchers GLOBAL PERFORMANCE SWITCHERS FEATURES: 4.1 W/in3 Compact (3.0 x 5.0 x 1.06) Ultra-high efficiency (up to 94%) using patented technology Meets harmonic requirements of IEC1000-3-2, Class A Conducted EMI exceeds FCC Class B and CISPR 22 Class B (Commercial models) and CISPR 11 Class B (Medical models) 2-year warranty Exempt from line harmonics standard EN61000-3-2 Commercial Approved to UL1950, IEC950, EN60950, CSA22.2 No. 950 Medical Approved to UL2601, EN60601, CSA22.2 No. 601.1 Multiple output versions also available RoHS models available (G suffix) marked to LVD SPECIFICATIONS Ac Input Inrush Current 90-264 Vac, 47-63 Hz single phase. Inrush is limited by internal thermistor. The inrush at 240 Vac, averaged over the first ac half-cycle under cold start conditions will not exceed 37A. Input Current Maximum input current at minimum output voltage and output overload EMI/EMC Compliance will be less than 1.7 A. Meets input current harmonic requirements of All models include built-in EMI filtering to meet the following emissions IEC1000-3-2. requirements: Output Power EMI SPECIFICATIONS COMPLIANCE LEVEL Normal continuous output power is 65 W, 75 W peak for 60 s. The 3.3 Vdc unit Conducted Emissions GLC65 EN55022 Class B FCC Class B is 36.3 W and the 5 Vdc unit is 55 W continuous. Conducted Emissions GLM65 EN55011 Class B: FCC Class B Hold-Up Time Static Discharge EN61000-4-2, 6 kV contact, 8 kV air 20 ms from loss of ac input at 65 W load, from 120 Vac input. RF Field Susceptibility EN61000-4-3, 3 V/meter Fast Transients/Bursts EN61000-4-4, 2 kV, 5 kHz Overload Protection Surge Susceptibility EN61000-4-5, 1 kV diff., 2 kV com. Fully protected against short circuit and output overload. Short circuit protec- tion is cycling type power limit. Commercial Leakage Current Output Noise Under normal conditions, leakage current is 425 A with 132 Vac 60 Hz input. 0.5% rms, 1% pk-pk, 20 MHz bandwidth, differential mode. Measured with Commercial Safety scope probe directly across output terminals of the power supply with load All GLC models are approved to UL1950, CSA22.2 No. 950, IEC950 and EN60950. terminated with 0.1 F capacitor. Medical Leakage Current Transient Response The maximum leakage current under single-fault conditions (254 Vac 50 Hz) is Main output: 500 s typical response time for return to within 0.5% of final 120 A. Under normal conditions, leakage current is 31A with 132 Vac 60 Hz value for a 50% load step within the regulation limits of minimum and maxi- input. mum load, i/t<0.2 A/s. Maximum voltage deviation is 3.5%. Startup/shut - down overshoot less than 3%. Medical Safety All GLM models are approved to UL2601, CSA22.2 No. 601, IEC601-1 and EN60601. Voltage Adjustment Consult factory for approval status. Adjustable potentiometer capable of 5% change from nominal setting. Temperature Coefficient: 0.03%C typical on all outputs. Efficiency 82 to 94% minimum at full rated load, nominal input voltage, depending on Remote Sense model. Provided as standard feature on all models. Includes open sense protection. Minimum Load No minimum load required. O All specifications are typical at nominal input, full load at 25 C unless otherwise statedCommercial Medical Output Current Total V1 Adjustment V1 OVP Setpoint Ripple Model Model Regulation and Noise GLC65-5 GLM65-5 5.1 V 9/11 A * 2% 5% 6.2 0.6 V 1% GLC65-12 GLM65-12 12 V 5.5 A 2% 5% 14 1.1 V 1% GLC65-15 GLM65-15 15 V 4.3 A 2% 5% 18.5 1.5 V 1% GLC65-18 GLM65-18 18 V 3.6 A 2% 5% 21.7 2.0 V 1% GLC65-20 GLM65-20 20V 3.25 A 2% 5% 24.5 2.2 V 1% GLC65-24 GLM65-24 24 V 2.7 A 2% 5% 28 2.5 V 1% GLC65-28 GLM65-28 28 V 2.3 A 2% 5% 34 2.8 V 1% GLC65-48 GLM65-48 48 V 1.35 A 2% 5% 55 4.0 V 1% Note: * 9 A convection, 11 A with fan cooling GLC65/GLM65 - SINGLE OUTPUT - MECHANICAL SPECIFICATIONS 1.20 30.28 ENVIRONMENTAL SPECIFICATIONS OPERATING NON-OPERATING A. Units should be allowed to warm up/operate under non-condensing conditions before application of power. Derate output current and total Temperature (A) 0 to 50 -40 to +85C output power by 2.5% per C above 50C. Humidity (A) 0 to 95% RH 0 to 95% RH B. Shock testinghalf-sinusoidal, 10 3 ms duration, direction, 3 Shock (B) 20 g 40 g orthogonal axes, total 6 shocks. pk pk Altitude -500 to 10,000 ft -500 to 40,000 ft C. Random vibration10 to 2000Hz, 6dB/octave roll-off from 350 to 2000Hz, 3 orthogonal axes. Tested for 10 min./axis operating and 1hr./ 2 2 Vibration (C) 1.5 g 0.003 g /Hz 5 g 0.026 g /Hz rms rms axis non-operating. SL Power Electronics Corp., 6050 King Drive, Bldg. A, Ventura, CA 93003, USA. Phone:(805) 486 4565 Fax:(805) 487 8911 www.slpower.com Rev. 01/07. Data Sheet 2007 SL Power Electronics, Inc. The information and specifications contained in this data sheet are believed to be correct at time of publication. However, SL Power accepts no responsibility for consequences arising from reproduction errors or inaccuracies. Specifications are subject to change without notice.